50740 EMIT, 50740 Datasheet

SmartLog V4 ESD/Static Protection Solid-State Touch Tester W/Software

50740

Manufacturer Part Number
50740
Description
SmartLog V4 ESD/Static Protection Solid-State Touch Tester W/Software
Manufacturer
EMIT
Datasheet

Specifications of 50740

Meter Display Type
Digital
Meter Function
Testing Of ESD Grounding Items, Single Or Dual-Wire Wrist Straps & Footwear
Features
TEAM 5 Software Allows For Easy Collection & Analysis Of Data Records
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
TB-6572 Page 1 of 6
SmartLog V4
Installation, Operation and Maintenance
Figure 1. EMIT SmartLog V4
Description
The EMIT SmartLog V4 is designed for fast, frequent, and
accurate testing of ESD personnel grounding items. By
touching the electrode button once the SmartLog V4 tests
the resistance path limits of the worn wrist strap and both
worn ESD footwear independently within one second. (Or
worn ESD garment if it is used as part of personnel grounding
path). Test results are electronically stored in the SmartLog
V4 and are easily downloaded to a PC for logging records
and evaluation. This product can be used as one of the
tools to fulfill the ANSI/ESD S20.20 section 7.3 “Compliance
Verification Plan”.
Paperless data can enhance operator accountability
immediately identifying problems while reducing logging and
auditing costs. There is no need to dedicate a computer for
each test station. The SmartLog V4 is a complete system
including all required components. Operator identification
can be accomplished by using the keypad, swiping a barcode
card, or waving a proximity card (verify compatibility with the
factory).
The SmartLog V4 can test either single or dual-wire wrist
straps; the split footplate design allows for individual footwear
testing all in one test. If a resistance path is below or exceeds
the set limits failure will be noted via audio and visual alarms.
Passing tests can enable a relay for automated door openers.
However, if the user desires to test the wrist strap and ESD
footwear separately this can be accomplished. The wrist
strap test is activated by inserting wrist strap plug into the
designated jack. See
information on setting individual test requirements.
As many as 32 SmartLogs can be daisy-chained and
connected to one computer allowing data to be collected
to one central computer for all SmartLogs. The SmartLog
V4 can also be networked to a company’s Intranet with
the optional 50461 Ethernet Adapter. The SmartLog V4 is
calibrated to NIST traceable standards.
December 2010
EMIT - 3651 Walnut Avenue, Chino, CA 91710 • (909) 664-9980 • Fax (909) 627-7449 • Website:
TECHNICAL BULLETIN TB-6572
TEAM5 Operation Manual
for more
The SmartLog V4’s default Wrist Strap test range is 1 - 10
megohms, and the default Footwear test range is 1 - 35
megohms. The ranges are easily adjusted.
TEAM5 Software
Use the powerful versatile TEAM5 Software to collect and
analyze records.
1) Specify tests and shifts for each employee in
2) Auto or manual polling of data to computer
3) Auto archive and network data posting
4) Allow data to be saved and stored automatically
5) Data retrieval at selectable time intervals
6) Allow easy data analysis
7)
See
ESD Association Information
“Compliance verification should be performed prior to each
use (daily, shift change, etc.). The accumulation of insulative
materials may increase the foot grounder system resistance.
If foot grounders are worn outside the ESD protected area
testing for functionality before reentry to the ESD protected
area should be considered.” ESD SP9.2 APPENDIX B - Foot
Grounder Usage Guidance
“Process monitoring (measurements) shall be conducted in
accordance with a Compliance Verification Plan that identifies
the technical requirements to be verified, the measurements
limits and the frequency at which those verifications shall
occur...Compliance verification records shall be established
and maintained to provide evidence of conformity to the
technical requirements.
The test equipment selected shall be capable of making the
measurements defined in the Compliance Verification Plan.”
(ANSI/ESD S20.20-2007) section 7.3
ANSI/ESD S20.20 Table 1 Flooring-Footwear Systems
Technical Requirements Recommended Range “less than 3.5
x 10E7 ohms measured per ANSI/ESD STM 97.1”.
“Typical test programs recommend that wrist straps that are
used daily should be tested daily. However, if the products
that are being produced are of such value that knowledge of
a continuous, reliable ground is needed, and then continuous
monitoring should be considered or even required.” (ESD
Handbook ESD TR 20.20 section 5.3.2.4.4)
Carefully unpack the SmartLog. The SmartLog comes ready to
install without any changes to the clock’s configuration.
If multiple SmartLogs are to be installed in a daisy-chain
configuration refer to page 5 for instructions.
database
Click Here
TEAM5 Operation Manual
to view the TEAM5 Comparison Chart
DescoEMIT.com
for more information.
© 2010 DESCO INDUSTRIES, INC.
Made in America
Employee Owned

50740 Summary of contents

Page 1

... V4 can also be networked to a company’s Intranet with the optional 50461 Ethernet Adapter. The SmartLog V4 is calibrated to NIST traceable standards. EMIT - 3651 Walnut Avenue, Chino, CA 91710 • (909) 664-9980 • Fax (909) 627-7449 • Website: December 2010 TB-6572 Page The SmartLog V4’s default Wrist Strap test range megohms, and the default Footwear test range megohms ...

Page 2

... SmartLog Access Controller and Numeric Keypad on mounting plate 1 AC Adapter 12VDC 500mA center pos. 4 Mounting Anchors 4 Mounting Screws EMIT - 3651 Walnut Avenue, Chino, CA 91710 • (909) 664-9980 • Fax (909) 627-7449 • Website: TB-6572 Page Features and Components A C Figure 2. SmartLog V4 features and components ...

Page 3

... The clock should not be installed on the same power line with devices containing electric motors. These units have a built-in EMIT - 3651 Walnut Avenue, Chino, CA 91710 • (909) 664-9980 • Fax (909) 627-7449 • Website: TB-6572 Page self-healing fuse and surge, spike, and noise protection. The clock should be powered on a dedicated electrical circuit ...

Page 4

... Figure 6. Back-side of SmartLog V4 plate Figure 7. Connecting one SmartLog V4 Figure 8. Connecting more than one SmartLog EMIT - 3651 Walnut Avenue, Chino, CA 91710 • (909) 664-9980 • Fax (909) 627-7449 • Website: TB-6572 Page DescoEMIT.com © 2010 DESCO INDUSTRIES, INC. Employee Owned ...

Page 5

... Connect the other end of the same pair of 18 gauge wires to the clock port labeled “RS-485” on the third SmartLog. 10. Set second SmartLog ID to 02. EMIT - 3651 Walnut Avenue, Chino, CA 91710 • (909) 664-9980 • Fax (909) 627-7449 • Website: TB-6572 Page Mounting the SmartLog Use the provided anchors and screws to mount the entire SmartLog plate ...

Page 6

... Limit of Liability In no event will EMIT or any seller be responsible or liable for any injury, loss or damage, direct or consequential, arising out of the use of or the inability to use the product. Before using, users shall determine the suitability of the product for their intended use, and users assume all risk and liability whatsoever in connection therewith. EMIT - 3651 Walnut Avenue, Chino, CA 91710 • ...