CRT1-ATT02 Omron, CRT1-ATT02 Datasheet - Page 2

no-image

CRT1-ATT02

Manufacturer Part Number
CRT1-ATT02
Description
Bracket 8 Pt Slave Econ
Manufacturer
Omron
Datasheet

Specifications of CRT1-ATT02

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Communications protocol
Types of communications
Baud rate
Modulation
Coding
Error control
Communications media
Communications distance and wiring
Connectable Master Units
Connectable Slave Units
Maximum I/O capacity
Maximum number of nodes
Bits allocated per node address
Maximum number of nodes per trunk line
or sub-trunk line
Applicable node addresses
Repeater Unit application conditions
Signal lines
Power lines
Connection forms
Communications Specifications
Item
CompoNet Network protocol
Remote I/O communications (programless, constant sharing of data with Slave Units) and message
communications (explicit message communications as required with Slave Units and FINS message
communications as required with PLCs)
4 Mbps, 3 Mbps, 1.5 Mbps, 93.75 kbps
Base-band
Manchester code
Manchester code rules, CRC
The following media can be used.
Note: Round cable I, round cable II, Flat Cable I, and Flat Cable II are all different types of cable. To use more
Refer to Cable Types, Baud Rates, and Maximum Distances in the Master Unit Operation Manual.
CompoNet Master Units
CompoNet Slave Units
Word Slave Units: 1,024 inputs and 1,024 outputs (2,048 I/O points total)
Bit Slave Units: 256 inputs and 256 outputs (512 I/O points total)
Word Slave Units: 64 input nodes and 64 output nodes
Bit Slave Units: 128 input nodes and 128 output nodes
Repeater Units: 64 nodes
Word Slave Units: 16 bits
Bit Slave Units: 2 bits
32 nodes (including Repeater Units)
Word Slave Units: IN0 to IN63 and OUT0 to OUT63
Bit Slave Units: IN0 to IN127 and OUT0 to OUT127
Repeater Units: 0 to 63
Up to 64 Repeater Units can be connected per network (i.e., per Master Unit). Up to 32 Repeater Units can be
connected per trunk line or per sub-trunk line. When Repeater Units are connected in series from the Master
Unit, up to two extra segment layers can be created (i.e., up to 2 Repeater Units are allowed between a Slave
Unit and the Master Unit).
Two lines: BDH (communications data high) and BDL (communications data low)
Two lines: BS+ and BS− (power for communications and internal Slave Unit circuits)
Standard or Sheathed Flat Cable at baud rate of 93.75 kbits/s: No restrictions
Other cables or baud rates: Trunk line and branch lines
Connections for Slave Units and Repeater Units: T-branch or multidrop connections
• Round cable I
• Round cable II
• Flat Cable I
• Flat Cable II
• Power is supplied from the Master Unit or Repeater Units.
than one type of cable at a time, Repeater Units must be used to separate them on trunk lines and sub-
trunk lines.
Communications Specifications
Specification
1

Related parts for CRT1-ATT02