CRT1-MD16SL Omron, CRT1-MD16SL Datasheet - Page 401
CRT1-MD16SL
Manufacturer Part Number
CRT1-MD16SL
Description
8 In 8 Out NPN Cage Clamp
Manufacturer
Omron
Datasheet
1.CRT1-ATT03.pdf
(675 pages)
Specifications of CRT1-MD16SL
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
- Current page: 401 of 675
- Download datasheet (14Mb)
Warning Status Area
Status Areas
The Temperature Input Unit's Warning Status Area contains the following 16
bits. These bits indicate minor errors in the Unit.
0
1
2
3
4
5
6
7
8
9
10
11
Bit
Master Unit
Reserved.
Reserved.
Network Power Voltage Drop Flag
OFF: Normal
ON: Error (Voltage dropped below
threshold.)
Unit Maintenance Flag
OFF: Normal
ON: Error (Threshold exceeded.)
Reserved.
Reserved.
Reserved.
Reserved.
Temperature Input Warning Flag
OFF: Within range (below set moni-
tor value)
ON: Out-of-range (equal to or above
set monitor value)
Cumulative Counter Exceeded Flag
OFF: Within range (below set moni-
tor value)
ON: Out-of-range (equal to or above
set monitor value)
Input Temperature Variation Detec-
tion Threshold Exceeded Flag
OFF: Within range (below set moni-
tor value)
ON: Out-of-range (equal to or above
set monitor value)
Set Temperature Range Total Time
Exceeded Flag
OFF: Within range (below set moni-
tor value)
ON: Out-of-range (equal to or above
set monitor value)
Transmitted to Master Unit
The status bit detection allocated to the master is OR
of all slaves
Temperature Input Unit
Content
The Status Area in the Temperature Input
Unit has a Warning Status Area and an
Alarm Status Area.
Cannot be used.
Cannot be used.
Turns ON when the Network Power
Voltage drops below the voltage set as
the threshold for monitoring.
Turns ON when the Total Unit Conduc-
tion Time exceeds the value set as the
threshold for monitoring.
Cannot be used.
Cannot be used.
Cannot be used.
Cannot be used.
Turns ON when the temperature data
exceeds the displayable range or the
monitor value set for the comparator
function.
Turns ON when the cumulative value
exceeds the set monitor value.
Turns ON when the difference between
input temperatures exceed the set mon-
itor value.
Turns ON when time in the set tempera-
ture range exceeds the set monitor
value.
Description
Section 7-3
377
Related parts for CRT1-MD16SL
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
Bracket 16 Pt Slave MIL
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
Bracket 8 Pt Slave Econ
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
CompoNet 8 NPN Inputs
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
CompoNet 8 PNP Inputs
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
8 In NPN Cage Clamp
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
8 In PNP Cage Clamp
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
8 In NPN 3 Tier
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
8 In PNP 3 Tier
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
8 In NPN 3 Tier
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
8 In PNP 3 Tier
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: