Specifications of CRT1-MD16TAH
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
- Current page: 28 of 675
- Download datasheet (14Mb)
Features of CompoNet Slave Units
Expansion Using
Expansion Units
Scaling
Last Maintenance Date
(Maintenance Function)
Cumulated Count
Moving Average
Setting the Number of AD
Conversion Points
Rate of Change
Calculations
Comparator
Peak/Bottom Hold
Top/Valley Hold
4
One Expansion Unit can be added to a Digital I/O Slave Unit (with 2-tier termi-
nal block and 16 points). This extends the range of possible system configura-
tions by making it possible to expand to a variety of I/O combinations, e.g., 16
inputs and 8 outputs or 24 inputs (16 inputs + 8 inputs).
Converted data can be scaled to any value by the user. Ladder program cal-
culations for the Master Unit are not required if the scaling function is used
with the Slave Unit. The offset compensation function can also be used to off-
set scaled values.
These settings are made by using the CX-Integrator.
The date that maintenance was performed can be written in the Slave Unit by
using the CX-Integrator.
The cumulated count function calculates the integral time for input (or output)
analog values and reads the cumulated value. Monitor values can be set in
Units. If the cumulated counter value exceeds the set monitor value, the
Cumulated Counter Over Flag in general status turns ON.
These values can be set and read by using the CX-Integrator.
An Analog Input Unit or Temperature Input Unit can calculate the moving aver-
age of the last eight inputs and use it as the converted data. Smooth input val-
ues can be obtained by averaging the inputs if there are rapid fluctuations in
the input.
Settings for averaging are made by using the CX-Integrator.
The conversion cycle is 4 ms max. when using all 4 analog inputs. The AD
conversion cycle can be made faster if fewer AD conversion points are used.
You can find the rate of change during the set data sampling cycle for the
input value to an Analog Input Unit or Temperature Input Unit.
The rate of change settings are made by using the CX-Integrator.
Input data captured into the Analog Input Slave Unit/Temperature Input Unit or
calculation data is compared to alarm settings (Alarm Trip Point High (HH),
Warning Trip Point High (H), Warning Trip Point Low (L), and Alarm Trip Point
Low (LL)) and the results can be reflected in the "Analog Status Flag" (or
"Temperature Data Status Flag"). The Normal Flag (pass signal) turns ON for
values that are in set range.
The alarm settings are made by using the CX-Integrator.
The peak/bottom hold function holds the maximum (peak) or the minimum
(bottom) input value to an Analog Input Unit or Temperature Input Unit. The
maximum (peak) or minimum (bottom) value can be compared with an alarm
set value and used to turn ON an alarm flag as status data. This is called the
comparator function.
The peak/bottom hold settings are made by using the CX-Integrator.
The top/valley hold function holds the top or valley input value to an Analog
Input Unit or Temperature Input Unit. The Top/Valley Detection Timing Flag
can be used to check when top and valley values were detected. The top and
valley values can be compared with an alarm set value and used as status
data to turn ON alarm flags (comparator function).
The top/valley hold settings are made by using the CX-Integrator.
Section 1-1
Related parts for CRT1-MD16TAH
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
Bracket 16 Pt Slave MIL
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
Bracket 8 Pt Slave Econ
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
CompoNet 8 NPN Inputs
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
CompoNet 8 PNP Inputs
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
8 In NPN Cage Clamp
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
8 In PNP Cage Clamp
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
8 In NPN 3 Tier
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
8 In PNP 3 Tier
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
8 In NPN 3 Tier
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
8 In PNP 3 Tier
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: