CRT1-OD08TA-1 Omron, CRT1-OD08TA-1 Datasheet - Page 337
CRT1-OD08TA-1
Manufacturer Part Number
CRT1-OD08TA-1
Description
8 Out PNP 3 Tier
Manufacturer
Omron
Datasheet
1.CRT1-ATT03.pdf
(675 pages)
Specifications of CRT1-OD08TA-1
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
- Current page: 337 of 675
- Download datasheet (14Mb)
6-2-3
I/O Data
Input Data
Summary of the Analog Input Slave Units
I/O Data Type and Allocation
Furthermore, "Analog Data 1" can be selected separately for each input as
described below.
Input CH3
Analog Input Slave Units support the following four types of input data, and
one type of output data. The required data can be allocated for I/O.
Data allocation is performed by CX-Integrator.
Input CH0
Input CH1
Input CH2
Analog Data 1
(4 input words (8
bytes))
Top/Valley Detection
Timing Flags (1 input
word (2 bytes))
Analog Status Flags
(2 input words (4
bytes))
Analog Data +
Top/Valley Detection
Timing Flags (5 input
words (10 bytes))
Note In default, "Raw Value" is to be allocated to I/O.
I/O data
Math
processing
Math
processing
Math
processing
Math
processing
• Used to monitor analog data.
• One type of data from the 4-word analog value, peak value,
Note The comparator function can be used with regards to
Top/Valley Detection Timing Flags are allocated in one word.
The flag is allocated together with the top or valley value in
order to identify the timing for the Master Unit to capture the
top or valley hold value.
Each of the bits for the Comparator Result Flag, Top/Valley
Detection Timing Flag, Disconnected Line Detection Flag are
allocated. The function of each bit is as follows:
• Comparator Result Flags
• Top/Valley Detection Timing Flag
• Disconnected Line Detection Flag
From the start, the Top/Valley Detection Timing Flag (1 word
(2 bytes)) is allocated to the end of analog data 1 (4 words (8
bytes)).
bottom value, top value, valley value, and rate of change is
selected and allocated. (The default is allocation of the ana-
log value.)
Allow control of the judgement results only, without allocat-
ing analog values.
Allocated simultaneously with top value and valley value
and used for data capture timing.
Disconnected line can be detected even if analog value is
not allocated.
Analog input
value
Other process-
ing results
Analog input
value
Other process-
ing results
Analog input
value
Other process-
ing results
Analog input
value
Other process-
ing results
the value allocated to analog data 1.
Details
Analog Data 1
Analog Data 1
Analog Data 1
Analog Data 1
Section 6-2
313
Related parts for CRT1-OD08TA-1
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
Bracket 16 Pt Slave MIL
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
Bracket 8 Pt Slave Econ
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
CompoNet 8 NPN Inputs
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
CompoNet 8 PNP Inputs
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
8 In NPN Cage Clamp
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
8 In PNP Cage Clamp
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
8 In NPN 3 Tier
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
8 In PNP 3 Tier
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
8 In NPN 3 Tier
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
8 In PNP 3 Tier
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: