H FRAME PRO ELEC, H FRAME Datasheet

FRAME, EXTENSION LEAD, 35M

H FRAME

Manufacturer Part Number
H FRAME
Description
FRAME, EXTENSION LEAD, 35M
Manufacturer
PRO ELEC
Datasheet

Specifications of H FRAME

Rohs Compliant
YES
Conditions for Use
An ambient temperature in the range -5°C to +40°C, the average value over 24 hours not exceeding 25°C.
A situation not subject to exposure to direct radiation from the sun or other source of heat like to raise temperatures above the
limits specified in a).
An altitude not exceeding 2000 metres above sea level.
An atmosphere no subject to abnormal pollution by smoke, chemical fumes, rain, spray, prolonged periods of high humidity or
other abnormal conditions.
Safety Specifications
Appearance
Marking
Insulation Resistance
Dielectric strength
Resistance to aging
Construction
Torque test
Glow Wire Test
Temperature rise
Make and break test of
switch
Cord Anchorage Test
Drop Test
Live parts accessibility
Cable Tidy
Item
500 + 250Vdc 1 minute
2000 ±60V 1 minute
70° ±5° 168 hours
20° ±5°
Value of 0.6Nm (6.1 kgf/cm)
650°/850° electrically heated
14A, 250V
13A, 250V, 15,000 times
3kg Pull force test for 0.5mm
6kg Pull force test for 1.0 mm
Fit with 3G1.25mm
height of 0.4m above the floor
Subjected to 1.0mm test probe with applied force
of 5N when they are mounted and wired as in
normal use.
Conditions
2
cable, 2.25m and drop at a
-
-
2
2
cable
or above cable
Page <1>
No defect such as cracks, deep scratches or
blemishes
Shall be legible and must be clear
Shall not be less than 5MΩ
No damage or breakdown
No cracks or become sticky
Complied with figure 11, 12, 14, 16 gauge
Terminal, cord grip and cover screws shall
withstand the torque applied
Flame must extinguish within 30 seconds
Temperature rise must not exceed:
1. Terminals or terminations
2. Accessible surface
Voltage drop across each switched pole shall not
exceed 75mV
The flexible cord shall not be displaced by more
than 2mm after being pull 25 times
No external damage which might affect safety and
no components shall have become detached
Live parts of socket shall not be accessible.
Features:
• 2 gang extension lead with 15cm.
Requirements
: 52K
: 52K
07/07/09 V1.0

Related parts for H FRAME

H FRAME Summary of contents

Page 1

Cable Tidy Conditions for Use An ambient temperature in the range -5°C to +40°C, the average value over 24 hours not exceeding 25°C. A situation not subject to exposure to direct radiation from the sun or other source of heat ...

Page 2

... This will not operate to limit or restrict the Group's liability for death or personal injury resulting from its negligence. Pro-Elec is the registered trademark of the Group. © Premier Farnell plc 2009. http://www.farnell.com http://www.newark.com http://www.cpc.co.uk Materials Remark 94- 13A,250V BSI Approved - BS6500 3 x 1.25mmsq - 94-V2 Part Number H FRAME Page <2> 07/10/09 V1.0 ...