374A-1 ELKAY, 374A-1 Datasheet

TIMER, PIR SENSOR, CEILING, VARIABLE

374A-1

Manufacturer Part Number
374A-1
Description
TIMER, PIR SENSOR, CEILING, VARIABLE
Manufacturer
ELKAY
Datasheet

Specifications of 374A-1

Time Range
2min To 2h
Colour
White
Contact Current Max
16A
Current Rating
16A
Mounting Type
Ceiling Mount
No. Of Inputs
3
Supply Voltage
240V
For Use With
Lighting, Heating, Ventilation
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
pirsensor
ceiling mount pirsensor fitting & operating instructions
Product: 374A-1, 374A-2 Three wire.
The ceiling mount pirsensor is part of the Elkay family of switches, timers and detectors
which save energy and increase convenience in and around your home, garden or premises.
POSITIONING
Use the detection range to determine a suitable location
for the sensor. When locating the position of the unit
avoid subjecting the sensor to direct sunlight. Ensure that
the sensor is not adjacent to the load. Do not site the
unit on a vibrating surface, or near a forced air heating or
ventilation. (see diagram 2)
MOUNTING AND INSTALLATION
Important Please note that it is essential that the Live In wire and switch Live Out is identified prior to commencing
installation. Turn off mains supply for installation.
Step 1 Cut a hole measuring 64mm in diameter in the chosen area for the sensor. Please see positioning.
Step 2 Place the Live In wire into the left hand position of the connector, the switched Live Out wire into the second from
left position of the connector and neutral into right hand position of connector. (see diagram 1)
Step 3 Fold the two arms up into the vertical position and insert unit into hole. Release unit ensuring arms are securely in
place.
Step 4 To set time, as per timing table, remove fascia ring by turning anti-clockwise one quarter turn to access switches one
through four. Depending on required time available from 2 minutes to 2 hours. E.g 10 minutes = switch one – off, switch two
– on, switch three – off, switch four – off. (see diagram 3)
Elkay Electrical, Coleshill, Birmingham, England.
Tel: +44 (0) 1675 468222 www.elkay.co.uk
USAGE
The PIR sensor has been
designed to replace a single
gang light switch, to control
lighting, heating and
ventilation. The unit is
switched on by the
detection of moving body
heat within a specified
range. When body heat is
no longer detected, the
unit will switch off after
the adjustable time period
has elapsed. If moving body
heat is detected again during the timing period, the timing sequence will restart.
The unit has a lux level adjustment, which measures the ambient light levels and
prevents lighting being switched on when there is sufficient light in the room.
Patent Pending Inst. Ref. No PIRC301 Rev. No.: 04/07
7 metres approx.
LIVE OUT
Diagram 2
NEUTRAL
LIVE IN
Diagram 1
CEILING
L
FLOOR
RATING AT 240V AC
Incandescent 16A
Fluorescent
Compact
Fluorescent
Resistive
Time Delay
16A
16A
16A
2mins - 2hours.
SWITCHES
ADJUSTMENT
LUX LEVEL
DIL

374A-1 Summary of contents

Page 1

... Product: 374A-1, 374A-2 Three wire. The ceiling mount pirsensor is part of the Elkay family of switches, timers and detectors which save energy and increase convenience in and around your home, garden or premises. POSITIONING Use the detection range to determine a suitable location for the sensor ...

Page 2

... All wiring should be carried out by a competent person or a qualified Electrician in accordance with the current IEE Wiring Regulations. If unit is faulty return to place of purchase. TECHNICAL HELPLINE For further help, or information on this and the other products in the Elkay range visit www.elkay.co.uk or call 01675 468222. Elkay Electrical, Coleshill, Birmingham, England. Tel: +44 (0) 1675 468222 www.elkay.co.uk 4 ...