AVB0.5/2/12 BLOCK, AVB0.5/2/12 Datasheet - Page 2

TRANSFORMER, 0.5VA, 2 X 12V

AVB0.5/2/12

Manufacturer Part Number
AVB0.5/2/12
Description
TRANSFORMER, 0.5VA, 2 X 12V
Manufacturer
BLOCK
Datasheet

Specifications of AVB0.5/2/12

Transformer Type
Isolation
Input Voltage
230V
Output Voltage
12V
Current Rating
0.020A
Power Rating
500mVA
Svhc
No SVHC (15-Dec-2010)
Ac Power
0.5VA
Approval Bodies
CSA, UL, VDE
External
RoHS Compliant
External Depth
19mm
Rohs Compliant
Yes
Description :
-------------
These AVB type resin moulded safety isolating transformers,
are inherently short-circuit proof so do not require external
protection. The dual input and output windings are for series or parallel connection.
Note :
* vacuum epoxy resin moulded (self-extinguishing to UL 94 V0)
* 100% tested
*
Output power 0,35 VA Core-type EE 20/6,1
Height 15,0 mm
Ground area 22 mm x 22,7 mm
-------------------------------------------
Type
........................................................................................
AVB 0,35/2/6
........................................................................................
AVB 0,35/2/8
........................................................................................
AVB 0,35/2/9
........................................................................................
AVB 0,35/2/12
........................................................................................
AVB 0,35/2/15* 2x15
........................................................................................
AVB 0,35/2/18* 2x18
........................................................................................
AVB 0,35/2/24* 2x24
........................................................................................
Pinning:
Input:2 x 115V..... (1-2) and (3-4)
Output ................. (5-6) and (7-8)
No load output voltage x Factor =
Core Losses
Efficiency
Ambient Temperature (ta)
Approvals
transformer specification
BLOCK TRANSFORMATOREN ELEKTRONIK GMBH & CO. KG, 27283 VERDEN, GERMANY
Subject to change
* =
Two chamber bobbin construction
according to VDE 0570/EN 61 558 -1 : 1997 with part 2-6
according to VDE 0570/EN 61 558 -1 : 1997 with part 2-1
SEC rated output-
voltage current
V
2x6
2x8
2x9
2x12
Weight 24g
A
2x0,029
2x0,021
2x0,019
2x0,014
2x0,011
2x0,009
2x0,007
(1)
Approvals
updated 07/2001
1
1
1
1
1
1
1
typ. 1,8
typ. 1,3 W
typ. 30 %
+70°C
2

Related parts for AVB0.5/2/12