VPL2-10000 Triad Magnetics, VPL2-10000 Datasheet

Power Transformer

VPL2-10000

Manufacturer Part Number
VPL2-10000
Description
Power Transformer
Manufacturer
Triad Magnetics
Type
Powerr
Series
Worldr
Datasheets

Specifications of VPL2-10000

Transformer Type
Power
Input Voltage
115V
Output Voltage
1.25V
Current Rating
20A
Power Rating
25VA
Transformer Mounting
Chassis
Peak Reflow Compatible (260 C)
No
Supply Voltage
230V
Output Current
20A
Brand/series
World Series™/VPL Series
Configuration
Bobbin
Current, Secondary
20/10 A
Dimensions
3.125"W×1.937"H×2.125"D
Frequency
50/60 Hz
Length, Lead
8 "
Mounting Hole Centers
2.812 "
Mounting Type
Panel/Chassis
Number Of Outlets
2
Phase
1
Power, Rating
25 VA
Standards
UL
Termination
Leadwires
Voltage, Primary
115/230 VAC
Voltage, Secondary
1.25/2.5 VAC
Weight
1.3 lbs.
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
VPL2-10000
Electrical Specifications (@25C)
1. Maximum Power: 25.0VA
2. Input Voltage – Series: 230VAC @ 50/60Hz
3. Output Voltage – Series: 2.5V CT@ 10.0A
4. Voltage Regulation: 20% TYP @ full load to no load
Construction:
Dual bobbin construction with an insulated shroud, both made of a high
temperature material that exceeds UL flammability requirements. Shrouds are
provided over the connections of the leads to the windings on both primary and
secondary coils. Devices are designed with a minimum of 6mm creepage distance
between the primary and secondary.
Safety:
These units are designed with 3500VAC isolation between the primary and
secondary, and also, between each winding and the core. Since the dual bobbin
construction effectively reduces capacitance, electrostatic shielding is not required.
International Series Transformers are designed and manufactured to meet most
International Safety agency standards.
Devices are manufactured with a Class B (130º C) insulation system.
Dimensions:
1.937
Weight: 1.3 lbs.
D. Mounting Holes: x 2
Schematic:
Input:
Output: Series – RED to GRY, Jumper YEL to VIO
Primary and secondary windings are designed to be connected in series or parallel. Windings are
not intended to be used independently.
RoHS Compliance:
requirements of 2002/95/EC, known as the RoHS initiative.
A
3.250
Parallel – BLK to WHT, Jumper BLK to BRN and WHT to BLU
Parallel – RED to VIO, Jumper RED to VIO and YEL to GRY
Series – BLK to BLU, Jumper WHT to BRN
B
3.125
C
Parallel: 115VAC@ 50/60Hz
As of manufacturing date February 2005, all standard products meet the
Parallel: 1.250V @ 20.0A
2.812
D
Units: In inches
8.00
E
WHT
BRN
BLU
BLK
.187
F
RED
YEL
GRY
VIO
P
Chassis Mount : International Series
O W E R
T
R A N S F O R M E R
F
A
B
D
C
E

Related parts for VPL2-10000

VPL2-10000 Summary of contents

Page 1

... VPL2-10000 Electrical Specifications (@25C) 1. Maximum Power: 25.0VA 2. Input Voltage – Series: 230VAC @ 50/60Hz Parallel: 115VAC@ 50/60Hz 3. Output Voltage – Series: 2.5V CT@ 10.0A Parallel: 1.250V @ 20.0A 4. Voltage Regulation: 20% TYP @ full load to no load Construction: Dual bobbin construction with an insulated shroud, both made of a high temperature material that exceeds UL flammability requirements ...

Page 2

... B 10 16.0 0.630 8.00 VPL16-600 VPL20-500 10 20.0 0.500 10.00 10 24.0 0.410 12.00 VPL24-400 VPL28-350 10 28.0 0.350 14.00 10 36.0 0.280 18.00 VPL36-300 VPL2-10000 25 2.5 10.000 1.25 25 10.0 2.500 5.00 VPL10-2500 VPL12-2000 25 12.6 1.980 6.30 25 16.0 1.570 8.00 VPL16-1600 C VPL20-1200 25 20.0 1.250 10. ...

Page 3

Primary and secondary windings are designed ...

Related keywords