ES5H25S SOLA HEVI DUTY, ES5H25S Datasheet

Distribution Transformer

ES5H25S

Manufacturer Part Number
ES5H25S
Description
Distribution Transformer
Manufacturer
SOLA HEVI DUTY
Datasheet

Specifications of ES5H25S

Transformer Mounting
Wall
No. Of Phases
Single
Mounting Type
Wall
External Height
28"
Power Rating
25kVA
Weight
254lb
Transformer Type
Distribution
Frequency
60Hz
External Width
16"
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
The Energy Policy Act of 2005 (H.R. 6) requires Distribution
Transformers manufactured after January 1, 2007 to meet
specifi c energy effi ciency requirements. EPAct 2005
defi nes the term “distribution transformers” as any
transformer which:
The following special purpose transformers are excluded
from the defi nition of “distribution transformers” and are,
therefore, not required to meet the energy effi ciency stan-
dards at this time:
Benefiting from Higher Energy Efficiencies
Increasing the energy effi ciency of a transformer allows the
unit to operate at the same level of power with less energy
being wasted in the process. Decreasing usage through
reduced waste by just .03% over the next 20 years cuts the
need for new power generation in the United States by 60 to
66 million kw.
SolaHD has been engineering and producing energy
effi cient transformers for the past six years. The SolaHD E
version transformers are optimized to meet NEMA’s TP-1
limits for load losses calculated to 35% of the name plate
rating, yet are the same compact size and footprint as its’
conventional 150˚C rise units.
The example pictured in Figure 1 shows the differences in
effi ciency for the old standard model compared to the
compliant model. At 35% load, the absolute difference in
effi ciency is only 1.7%. However, that represents a 52%
reduction in wasted energy. Taking that 52% reduction in
wasted energy and multiplying it across all the energy
consumed results in substantial savings.
184
6
• Autotransformers
• Drive (isolation) transformers
• Grounding transformers
• Machine-tool (control) transformers
• Non-ventilated transformers
• Rectifi er and Regulating transformers
• Sealed transformers
• Special-impedance transformers
• Testing transformers
• Transformer with tap range of 20% or more
• Uninterruptible power supply transformers
• Welding transformers
• Has an input voltage of 34.5 kVA or less
• Has an output voltage of 600 V or less
• Is rated for operation at a frequency of 60 Hz
• Has a capacity of 10 kVA to 2500 kVA for
liquid-immersed units and 15 kVA to 2500 kVA
for dry-type units
Ventilated Distribution Transformers
contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solaheviduty.com or
SolaHD offers the following family of transformers that meet
the strict effi ciency standards. The effi ciencies of these trans-
formers are op ti mized for the load losses calculated
at 35% of the name plate rating. This 35% represents an
industry average load of most LVGP trans form ers.
Applications
Any situation where the available voltage must be changed
to accommodate the voltage required by the specifi c
elec tri cal circuit or connected equipment. For many
elec tri cal circuits, the National Electrical Code (NEC)
requires a separately derived neutral secondary connection
provided by Delta-Wye connected transformers.
Distribution transformers can be located close to the load.
No vaults are required for installation and no long, ex pen sive
feeder lines are needed. Common ap pli ca tions include
inductive and re sis tive loads such as motors, lighting and
heating.
General Purpose Transformers
Transformers designed to meet the high energy effi ciencies
required by NEMA Standard TP-1.
Low Temperature Rise Transformers
Transformers designed to limit the temperature rise of the
core and coil assembly to either 80°C or 115°C above a
40°C ambient. Reduction in temperature rise increases
reliability.
K-Factor Transformers
Transformers designed to withstand the electrical anomalies
associated with solid state equipment and DC power
supplies (ex clud ing SCR variable speed motor drives)
without derating the nameplate kVA.
Copper Wound Transformers
SolaHD general purpose transformers have standard
aluminum coil windings. As an option, we offer a selection
with copper windings.
Figure 1

Related parts for ES5H25S

ES5H25S Summary of contents

Page 1

... United States million kw. SolaHD has been engineering and producing energy effi cient transformers for the past six years. The SolaHD E version transformers are optimized to meet NEMA’s TP-1 limits for load losses calculated to 35% of the name plate rating, yet are the same compact size and footprint as its’ ...

Page 2

... Electrostatically shield ed for quality power • Terminal board connections and spacious wiring compartment Selection Tables: Single Phase Group 1: 240 x 480 Volt Primary, 120/240 Secondary Catalog NEMA 3R kVA Number Weather Shield* 15 ES5H15S WS-15 25 ES5H25S WS-15 37.5 ES5H37S WS-17 50 ES5H50S WS-17 75 ES5H75S WS-09 100 ES5H100S WS-09 ...

Page 3

... Ventilated Distribution Transformers Selection Tables: Single Phase Group 3 – 600 Volt Primary, 120/240 Secondary Catalog NEMA 3R kVA Number Weather Shield* 15 ES10H15S WS-15 25 ES10H25S WS-15 37.5 ES10H37S WS-17 50 ES10H50S WS-17 75 ES10H75S WS-09 100 ES10H100S WS-09 167 ES10H167S WS-16 Group 4 – Export 190/200/208/220/380/400/415/440 Volt Primary, 110/220 Secondary, 50/60 Hz ...

Page 4

... Weather shields (set of two) must be ordered separately. **Design Style and Electrical Connections can be found on pages 204-205. ***See the Technical Notes section with respect to capacity of center tap. contact Technical Services at (800) 377-4384 with any ques tions. Ventilated Distribution Transformers Height Width Depth Approx ...

Page 5

... Ventilated Distribution Transformers Selection Tables: Three Phase Group E: 208 Volt Δ Primary, 208Y/120 Secondary Catalog NEMA 3R kVA Number Weather Shield* 15 ET3H15S WS-02 30 ET3H30S WS-14 45 ET3H45S WS-14 75 ET3H75S WS-30 112.5 ET3H112S WS-30 150 ET3H150S WS-10 Group F: 240 Volt Δ Primary, 208Y/120 Secondary ...

Page 6

... WS-11 500 ET2H500SCU WS-12 Notes: * Weather shields (set of two) must be ordered separately. **Design Style and Electrical Connections can be found on pages 204-205. contact Technical Services at (800) 377-4384 with any ques tions. Ventilated Distribution Transformers Height Width Depth Ship Weight (inch) (inch) (inch) Approx ...

Page 7

... Figure 2). Low temperature rise transformers are designed for any criti- cal application requiring extra overload capability, lower than average total losses and/or cooler operating temperatures. All are available with either a 115° ...

Page 8

... Weather shields (set of two) must be ordered separately. **Design Style and Electrical Connections can be found on pages 204-205. ***See the Technical Notes section with respect to capacity of center tap. contact Technical Services at (800) 377-4384 with any ques tions. Ventilated Distribution Transformers C Rise o C Rise ...

Page 9

... Ventilated Distribution Transformers Selection Tables: Low Temperature Rise, Single Phase, 115 Group 1: 240 x 480 Volt Primary, 120/240 Secondary, 60 Hz, 115 Catalog Number NEMA 3R kVA 115°C Rise Weather Shield* 15 ES5HF15S WS-15 25 ES5HF25S WS-15 37.5 ES5HF37S WS-17 50 ES5HF50S WS-17 75 ES5HF75S WS-09 100 ...

Page 10

... Weather shields (set of two) must be ordered separately. **Design Style and Electrical Connections can be found on pages 204-205. ***See the Technical Notes section with respect to capacity of center tap. contact Technical Services at (800) 377-4384 with any ques tions. Ventilated Distribution Transformers C Rise o C Rise ...

Page 11

... Chart A. The K-Factor rating is an index of the trans form er’s ability to withstand harmonic con tent while operating within the temperature limits of its insulating system. SolaHD K-Factor transformers have UL ratings of K-4, K-13, and K-20. The SolaHD K-Factor design is a specialized transformer that offers these benefi ...

Page 12

... WS-11 300 3H20T2H300S WS-12 Notes: * Weather shields (set of two) must be ordered separately. **Design Style and Electrical Connections can be found on pages 204-205. contact Technical Services at (800) 377-4384 with any ques tions. Ventilated Distribution Transformers Height Width Depth Approx. Ship (inch) (inch) (inch) ...

Page 13

... Ventilated Distribution Transformers Electrical Connections (Single Phase) 240 x 480 Volt Primary, 120/240 Volt Sec ond ary 1 Taps: 2, 2½% FCAN; 4, 2½% FCBN SHIELD Connect Primary Voltage Interconnect Lines To 504 & H2 492 & H2 480 & H2 468 & H2 456 & H2 444 & H2 ...

Page 14

... ET81 Series contact Technical Services at (800) 377-4384 with any ques tions. Ventilated Distribution Transformers 480 Δ Volt Primary, 6 240 Δ W/120 CT Volt Sec ond ary Taps: 2, 2½% FCAN; 4, 2½% FCBN SHIELD X6 X1 ...

Page 15

... Non-Ventilated Automation Transformers Electrical Connections (Three Phase) 240 Volt Primary Δ 11 208Y/120 Volt Secondary Taps: 2, 2½% FCAN; 4, 2½% FCBN SHIELD Primary H1-H2-H3 Secondary Voltage @ Tap Voltage X1, X2, X3 X0- X1, X2 252 2 246 3 240 4 234 208 120 5 228 6 222 7 216 ET6 Series ...

Related keywords