J 63 03 VERMASON, J 63 03 Datasheet

PLUG, EARTH BONDING POINT

J 63 03

Manufacturer Part Number
J 63 03
Description
PLUG, EARTH BONDING POINT
Manufacturer
VERMASON
Datasheet

Specifications of J 63 03

End To Ground Resistance
1Mohm
No. Of Studs
3
Approval Bodies
EN 100015-1
Svhc
No SVHC (18-Jun-2010)
Colour
Yellow
No. Of Stud Size 1
3
Standard
EN100015-1
Stud Size 1
10mm
Terminal Type
St
Lead Free Status / RoHS Status
na
Note: To avoid the need for unduly long ground cords and to simplify the daily visual check
To fit UK mains sockets
The Vermason Earth Bonding Point (EBP) plug is designed to provide a safe effective and easy to use
earthing point in an ESD protected area (EPA). The plug fits into the mains supply socket, making a
connection with the earth conductor only. In place of the live and neutral pins are moulded insulating
plastic pins to allow positive location in the socket. Connectors on the front of the plug are available
for connection via ground cords to the various elements of the EPA. Thus each element is held at a
common potential.
The normal earth pin is linked via individual 1 MΩ resistors rated at 1 Watt to each connector on the
If overstressed the resistor will open the circuit.
It is virtually impossible to misuse the plug, which is permanently sealed. The resistance between the
terminations and the pin of each plug is tested after manufacture.
Instructions for use
Check that the connectors on the plug face correspond with the terminations on the wrist strap and
ground cords: several variations of the plug are available.
Insert the EBP plug into a mains supply socket and push it fully home. The plug functions safely
whether the socket is switched off or on.
Connect the elements of the EPA such as bench mat and floor mat to the EBP plug face using ground
cords.
The EBP plug may also be used in conjunction with a Vermason EBP box or bar installed at the front
of a bench for easier connecting of wrist straps for example.
front of the plug. In the event of a workstation element becoming live the resistor will limit the fault
current to less than 0.3 mA at 240 V supply.
that all connections are sound and in place, an EBP plug should not be shared by more
than two work stations.
Page 1 of 2
Farnell Part No 936-868, 254-356, 254-370
EARTH BONDING POINT PLUG
Product Information
Issue No 2
Code J6300 to J6350
Date May 2003
No: PIS 025
Approved by
/Contd … .

J 63 03 Summary of contents

Page 1

... EBP plug should not be shared by more than two work stations. The EBP plug may also be used in conjunction with a Vermason EBP box or bar installed at the front of a bench for easier connecting of wrist straps for example. ...

Page 2

... Mass: Connector to earth pin resistance: Connector to connector resistance: Packaging EBP plugs are packed and labelled individually in a polyethylene bag Vermason Ltd, 1 Avenue One, Letchworth, Hertfordshire SG6 2HB. UK Issue No 2 May 2003 3x4 mm press stud 3x10 mm press stud 2x4 mm, 1x10 mm press stud ...