J6100 VERMASON, J6100 Datasheet

SCHUKO, VERMASON, J6100, 1X4MM/2X10MM

J6100

Manufacturer Part Number
J6100
Description
SCHUKO, VERMASON, J6100, 1X4MM/2X10MM
Manufacturer
VERMASON
Datasheet

Specifications of J6100

End To Ground Resistance
1Mohm
No. Of Studs
3
Approval Bodies
EN 100015-1
Svhc
No SVHC (18-Jun-2010)
Colour
Yellow
No. Of Stud Size 1
2
No. Of Stud Size 2
1
Standard
EN100015-1
Stud Size
RoHS Compliant
Stud Size 1
10mm
Stud Size 2
4mm
Rohs Compliant
NA
To fit UK European CEE (7) VII Schuko sockets as used in Belgium, France, Germany,
Holland, Spain.
The Vermason Earth Bonding Point (EBP) plug is designed to provide a safe effective and easy to
use earthing point in an ESD protected area (EPA). The plug fits into the mains supply socket,
making a connection with the earth conductor only. In place of the live and neutral pins are
moulded insulating plastic pins to allow positive location in the socket. Connectors on the front
of the plug are available for connection via ground cords to the various elements of the EPA.
Thus each element is held at a common potential, namely earth.
The normal earth contact is linked via individual 1 MΩ resistors rated at 1 Watt to each connector
on the front of the plug. In the event of a workstation element becoming live the resistor will limit
the fault current to less than 0.3 mA at 240 V supply.
It is virtually impossible to misuse the plug, which is permanently sealed. The resistance between
the terminations and the pin of each plug is tested after manufacture.
Instructions for use
Check that the connectors on the plug face correspond with the terminations on the wrist strap and
ground cords: several variations of the plug are available.
Insert the EBP plug into a mains supply socket and push it fully home. The plug functions safely
whether the socket is switched off or on.
Connect the elements of the EPA such as bench mat and floor mat to the EBP plug face using
ground cords.
Note: To avoid the need for unduly long ground cords and to simplify the daily visual check that
all connections are sound and in place, an EBP plug should not be shared by more than two work
stations.
The EBP plug may also be used in conjunction with a Vermason EBP box or bar installed at the
front of a bench for easier connecting of wrist straps for example.
EUROPEAN EARTH BONDING POINT PLUG
Page 1 of
1
Code J6100 to J6120
Product Information
Issue No 3
Date : May 2003
No: PIS 008
Approved by:
/Contd….

J6100 Summary of contents

Page 1

... EBP plug should not be shared by more than two work stations. The EBP plug may also be used in conjunction with a Vermason EBP box or bar installed at the front of a bench for easier connecting of wrist straps for example. Product Information 1 Issue No 3 Date : May 2003 Code J6100 to J6120 No: PIS 008 Approved by: /Contd…. ...

Page 2

... PIS 008 Technical Information Plug codes and their corresponding connectors: J6100 1 x 4mm 10mm press stud J6101 1 x 4mm 7mm press stud J6102 3 x 4mm press stud J6103 3 x 10mm press stud J6104 3 x 7mm press stud J6105 2 x 7mm 10mm press stud ...