60600 Desco, 60600 Datasheet

no-image

60600

Manufacturer Part Number
60600
Description
IONIZER, OVERHEAD, 40IN W/ LIGHT & HEATER
Manufacturer
Desco
Datasheet

Specifications of 60600

Ionizer Type
Overhead
Flow Rate Max
260CFM
Width
5.25"
Height
2.75"
Mounting Type
PCB
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na
TB-3006 July 2010 Page 1 of 4
Figure 1. High Output Overhead Ionizer
Description
The Desco 40" High Output Overhead Ionizer is designed
to neutralize electrostatic charges over a large work
area. The unique active feedback and balance circuit
automatically ensures and maintains the unit’s ion offset
voltage balance, despite variations in line voltage, air speed
or emitter electrode condition. The ionizer’s feedback circuit
also gives an audible and visual alarm indication when
maintenance is required. The overhead mounting design of
this ionizer allows it to provide maximum coverage without
consuming valuable work bench space. The need for
maintenance is minimized, while maximum neutralization
efficiency and overall performance is attained.
This overhead ionizer is unique - it comes equipped with
two factory installed lights and three heaters. The lights
are on continuously whenever the ionizer is turned on and
allow for better vision at the workstation. The heaters
are activated by a switch on the face of the ionizer. The
heaters will raise the temperature of the output air to about
10° above ambient. The heaters are only to offset the chill
factor of the moving air. They are not intended to warm the
workstation.
Ionizers are useful in preventing electrostatic charge
generation, ElectroStatic Discharge, ElectroStatic Attraction,
as well as preventing equipment latch-up and safety related
shock. Per ANSI/ESDS20.20-2007 section 8.3 “In order
to mitigate field-induced CDM [Charged Device Model]
damage, the ESD program shall include a plan for the
handling of process-required insulators. If the field exceeds
2,000 volts/inch, steps shall be taken to either: A) Separate
the insulator from the ESD-sensitive device by a distance
of 30 cm (12 inches); or B) Use ionization or other charge
mitigating techniques to neutralize the charge.”
Ionization is used to neutralize charges on process
necessary insulators and isolated semiconductors. Some
examples of process necessary insulators are: the PC
board itself, plastic test stands, plastic housing where
a PCB may be mounted, as well as computer monitor
High Output Overhead Ionizer
Installation, Operation and Maintenance
DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Web Site:
TECHNICAL BULLETIN TB-3006
DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449
IONIZER SELECTION
ANSI/ESD S20.20 paragraph 6.1.1.2. ESD Control Program
Plan Guidance states: “The Plan should include a listing of
the specific type of ESD protective materials and equipment
used in the Program.” When selecting an ionizer life cycle
costs should be considered including: equipment cost,
installation cost, and operation and maintenance cost.
Figure 2. Area of optimum charge neutralization
The unit provides better coverage without using excessive
bench space. The ionizer’s discharge times (neutralization
efficiency) is optimal at approximately 12" to 24" above the
work surface, and will drop off as the distance from the unit
increases.
*Never use incandescent lamps in the
Contact Desco Customer Service at (909) 627-8178 for
lamp replacement information.
screens and regular cleaning wipes. Examples of floating
or isolated conductors are: loaded PCB mounted in a
stand where the pins are not contacting the dissipative
workstation. Ionization is not effective on items that have
large capacitance, like people and carts; however, ionizers
should be considered as a method for charge neutralization
in cases where grounding cannot be achieved.
“Ionizers should be considered as a method for charge
neutralization in cases where grounding cannot be
achieved.” …“Air ionization can neutralize the static charge
on insulated and isolated objects by producing separate
charges in the molecules of the gases of the surrounding
air. When a static charge is present on objects in the work
environment, it will be neutralized by attracting opposite
polarity charges from the ionized air.” (EN 61340-5-2
paragraph 5.2.9)
This ionizer is NIST calibrated and comes equipped with
universal IEC cord connectors.
Model
60600
24 IN.
Voltage / Hz
120 / 50-60
Light & Heater
Yes
Desco.com
60600
© 2010 DESCO INDUSTRIES INC.
ionizer.
IEC Cord
Made in America
7' 6"
Employee Owned

60600 Summary of contents

Page 1

... Contact Desco Customer Service at (909) 627-8178 for lamp replacement information. Desco.com Made in America IEC Cord 7' 6" 60600 ionizer. © 2010 DESCO INDUSTRIES INC. Employee Owned ...

Page 2

... CA) or 781-821-8370 (Canton, MA). DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Web Site: TB-3006 Page Air filter Figure 5 ...

Page 3

... DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Web Site: TB-3006 Page Figure 7. Discharge times in seconds from ± ...

Page 4

... Figure 8. Audio On/Off and Alarm and Balance Adjustment of High Output Overhead Ionizer. DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Web Site: TB-3006 Page Health There are no known health risks associated with our devices ...