42540 Loctite, 42540 Datasheet - Page 2

THREADLOCKER ADHESIVE, BOTTLE, 20G

42540

Manufacturer Part Number
42540
Description
THREADLOCKER ADHESIVE, BOTTLE, 20G
Manufacturer
Loctite
Series
425r
Datasheet

Specifications of 42540

Color
Blue
Dispensing Method
Bottle
Weight
20g
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
4254031A910-000
Manufacturer:
DELTA
Quantity:
20 000
IDH number: 135461
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected
Skin contact:
Eye contact:
Ingestion:
Notes to physician:
Flash point:
Autoignition temperature:
Flammable/Explosive limits - lower:
Flammable/Explosive limits - upper:
Extinguishing media:
Special firefighting procedures:
Unusual fire or explosion hazards:
Hazardous combustion products:
Environmental precautions:
Clean-up methods:
Handling:
6. ACCIDENTAL RELEASE MEASURES
5. FIRE FIGHTING MEASURES
7. HANDLING AND STORAGE
Do not pull bonded skin apart. Soak in warm soapy water. Gently peel apart
using a blunt instrument. If skin is burned due to the rapid generation of heat
by a large drop, seek medical attention. If lips are bonded, apply warm water
to the lips and encourage wetting and pressure from saliva in mouth. Peel or
roll lips apart. Do not pull lips apart with direct opposing force.
Immediately flush with plenty of water for at least 15 minutes. Get medical
attention. If eyelids are bonded closed, release eyelashes with warm water by
covering with a wet pad. Do not force eye open. Cyanoacrylate will bond to
eye protein and will cause a lachrymatory effect which will help to debond the
adhesive. Keep eye covered until debonding is complete, usually within 1-3
days. Medical attention should be sought in case solid particles of polymerized
cyanoacrylate trapped behind the eyelid caused abrasive damage.
Ensure breathing passages are not obstructed. The product will polymerize
rapidly and bond to the mouth making it almost impossible to swallow. Saliva
will separate any solidified product in several hours. Prevent the patient from
swallowing any separated mass.
Surgery is not necessary to separate accidentally bonded tissues. Experience
has shown that bonded tissues are best treated by passive, non-surgical first
aid. If rapid curing has caused thermal burns they should be treated
symptomatically after adhesive is removed.
80 - 93.3 °C (176°F - 199.94 °F) Tagliabue closed cup
Not determined
Not determined
Not determined
Water spray or fog. Dry powder. Foam. Carbon dioxide.
Wear a self-contained breathing apparatus with a full face piece operated in
pressure-demand or other positive pressure mode.
None
Trace amounts of toxic and/or irritating fumes may be released and the use of
breathing apparatus is recommended.
Ventilate area. Do not allow product to enter sewer or waterways.
Do not use cloths for mopping up. Flood with water to complete polymerization
and scrape off the floor. Cured material can be disposed of as non-hazardous
waste.
Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist.
Wash thoroughly after handling. Avoid contact with fabric or paper goods.
Contact with these materials may cause rapid polymerization which can
generate smoke and strong irritating vapors, and cause thermal burns.
Product name: 425 Assure(TM) Instant Adhesive Surface Curing Threadlocker
personnel.
Page 2 of 5