1743-QT Techspray, 1743-QT Datasheet - Page 4

ANTISTATIC CLEANER, SPRAY, 1QUART

1743-QT

Manufacturer Part Number
1743-QT
Description
ANTISTATIC CLEANER, SPRAY, 1QUART
Manufacturer
Techspray
Series
Zero Charger
Type
Removerr
Datasheet

Specifications of 1743-QT

Cleaner Type
Antistatic
Cleaner Applications
Computer Displays, Keyboards
Dispensing Method
Trigger Spray
Volume
1quart (US)
Application
For regular use on screen & keyboard
Chemical Component
2-Butoxyethanol/Ethanol/Isopropyl Alcohol/Methanol/Methyl Isobutyl Ketone/Nonylphenoxypoly(ethyeneoxy)-Ethanol/Propane/Isobutane/n-Butane/Quaternary Ammonium Compounds/Water
Physical State
Liquid
Primary Type
Cleaner
Special Features
Anti-Static
Weight
1 qt.
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
9. PHYSICAL AND CHEMICAL PROPERTIES
Ethanol
Methanol
Zero Charge Screen & Keyboard Cleaner
PERSONAL PROTECTIVE EQUIPMENT
WORK HYGIENIC PRACTICES: Wash hands before eating and wash before reuse.
PHYSICAL STATE: Liquid
ODOR: Alcohol odor
COLOR: Yellow to Amber
pH: 7.0
PERCENT VOLATILE: 99
VAPOR PRESSURE: Not Applicable
VAPOR DENSITY: Not Available
BOILING POINT: 60°C (150°F)(760 mmHg)
FREEZING POINT: Not Determined
SOLUBILITY IN WATER: 100
EVAPORATION RATE: Not Established
DENSITY: 0.88 at 25°C
VISCOSITY: Not Applicable
MOLECULAR WEIGHT: Not Applicable
(VOC): 541.2 g/L
(VOC) NOTES: Non-exempt
OSHA TABLE COMMENTS:
1. S = Skin
EYES AND FACE: For normal conditions, wear safety glasses. Where there is reasonable probability of liquid
contact, wear splash-proof goggles.
SKIN: The glove(s) listed below may provide protection against permeation. Gloves of other chemically
resistant materials may not provide adequate protection. Viton, Solvex, Butyl, Buna, Neoprene.
RESPIRATORY: NIOSH/MSHA approved air purifying respirator with an organic vapor cartridge or canister
may be permissible under certain circumstances where airborne concentrations are expected to exceed exposure
limits. Protection provided by air purifying respirators is limited. Use a positive pressure air supplied respirator if
there is any potential for an uncontrolled release, exposure levels are not known, or any other circumstances
where air purifying respirators may not provide adequate protection.
PROTECTIVE CLOTHING: NOT listed
COMMENTS:
TWA
STEL
TWA
STEL
ppm
1000
ppm
NL
ppm
S 200
ppm
250
ppm
[1]
mg/m
1900
mg/m3
NL mg/
m3
260 mg/
m3
310 mg/
m3
3
ppm
1000
ppm
NL
ppm
S 200
ppm
250
ppm
mg/m
1880
mg/m3
NL mg/
m3
262 mg/
m3
328 mg/
m3
3
ppm
NL
NL
NL
ppm
NL
ppm
mg/m
NL
NL
NL mg/
m3
NL
3