3046090 Phoenix Contact, 3046090 Datasheet - Page 2

TERM BLK MOD FUSE 26-10AWG BLACK

3046090

Manufacturer Part Number
3046090
Description
TERM BLK MOD FUSE 26-10AWG BLACK
Manufacturer
Phoenix Contact
Series
CLIPLINE UTr
Type
Fusedr
Datasheets

Specifications of 3046090

Number Of Positions
2
Number Of Levels
1
Terminal - Width
6.2mm
Termination Style
Screw Clamp
Current - Iec
6.3A
Voltage - Iec
500V
Current - Ul
6.3A
Voltage - Ul
600V
Wire Gauge Or Range - Awg
10-26 AWG
Wire Gauge Or Range - Mm²
0.14-6mm²
Features
Fuse, 5mm x 20mm, LED
Color
Black
Product
DIN Rail Terminal Blocks
Number Of Positions / Contacts
2
Wire Gauge Range
26-10
Current Rating
6.3 A
Voltage Rating
500 V
Flammability Rating
UL 94 V-0
Height
80.5 mm
Length
57.8 mm
Width
6.2 mm
Wire Gauge Max (awg)
10
Wire Gauge Min (awg)
26
Agency Approvals
cULus, CSA
Contamination Class
3
Current, Rating
6.3 A
Dimensions
6.2 mm x 56.8 mm
Fuse Type
Glass
Insulation Material
PA
Number Of Poles
2 Poles
Phoenix Part Number
UT 4-HESILED 24(5X20)
Pin Spacing
6.2 mm
Primary Type
DIN Rail
Rated Surge Voltage
4 kV
Stripping Length
9 mm
Termination
Screw
Voltage, Rating
500 V
Wire, Awg
26-10
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
277-2035
UT 4-HESILED 24 (5X20)
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=3046090
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
Dimensions
Width
Length
Height NS 35/7,5
Height NS 35/15
Technical data
Fuse
Fuse type
LED voltage range
Rated surge voltage
Pollution degree
Surge voltage category
Insulating material group
Connection in acc. with standard
Nominal current I
Nominal voltage U
Power loss
LED voltage range
LED current range
Connection data
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section stranded min.
Conductor cross section stranded max.
Conductor cross section AWG/kcmil min.
Conductor cross section AWG/kcmil max
N
N
Order No.: 3046090
6.2 mm
57.8 mm
73 mm
80.5 mm
G / 5 x 20
Glass
12 V AC/DC ... 30 V AC/DC
6 kV
3
III
I
IEC 60947-7-3
6.3 A (if used as disconnect terminal block. With fuse, the current
is determined by the fuse used.)
500 V (if used as disconnect terminal block. With fuse, the
voltage is determined by the light indicator used.)
500 V (if used as disconnect terminal block. With fuse, the
voltage is determined by the light indicator used.)
≥ 1.6 W (With single arrangement of the fuse terminal block in the
event of overload)
≥ 1.6 W (With interconnected arrangement of several fuse
terminal blocks in the event of overload)
≥ 4 W (With single arrangement of the fuse terminal block in the
event of a short-circuit)
≥ 2.5 W (With interconnected arrangement of several fuse
terminal blocks in the event of a short-circuit)
12 V AC/DC ... 30 V AC/DC
1 mA ... 3 mA
0.14 mm²
6 mm²
0.5 mm²
6 mm²
26
10
Mar 24, 2010