1013700000 Weidmuller, 1013700000 Datasheet - Page 15

no-image

1013700000

Manufacturer Part Number
1013700000
Description
TERM BLK W/DIODE&WIRE LINK BG
Manufacturer
Weidmuller
Series
Wr
Type
Disconnectr
Datasheet

Specifications of 1013700000

Number Of Positions
2
Number Of Levels
1
Terminal - Width
5.1mm
Termination Style
Screw
Current - Iec
14A
Voltage - Iec
500V
Current - Ul
10A
Voltage - Ul
300V
Wire Gauge Or Range - Awg
12-22 AWG
Wire Gauge Or Range - Mm²
2.5mm²
Features
Removable Diode
Color
Beige
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
WTR 2.5/D/DRBR
16
Mode of operation
Operating status
SAKT E
Test mode
For insulation measurements with voltages >U
be disconnected.
SAKT E
For insulation measurements with voltages >U
be disconnected.
Operating status
SAKT E
Earth Test/Disconnect Terminals
Green and red indicators
light up with reduced
intensity
Earth connection disconnected
– Slide link enclosed
– Auxiliary current circuit earthed
– Green indicator illuminated
– Slide link open
– Auxiliary current circuit not earthed
– No earth fault
– Slide link open
– Auxiliary current circuit not earthed
– Earth fault
– Red indicator illuminated
SAKA 10
SAKA 10
SAKA 10
– No indication
rated
rated
, earth must
, earth must
SAKT E/SAKA 10
Length
Height (incl. TS 32/TS 35x7.5)mm
Insulation stripping length mm
Screw connection, solid
Screw connection, flexible
Conductor cross-section
Wechselspannung
Gleichspannung
Current
Cross-section
Type
Cat. No. (6 mm
for TS 32 Y
Type
Cat. No. (6 mm
for TS 35 W
Type
Cat. No. (10 mm
for TS 32 Y
Type
Cat. No. (10 mm
for TS 32 Y/TS 35 W
Mounting rail (2 m lengths)
End bracket
(Thickn. 8.5 mm)
Earthing auxiliary circuits
Earth faults in control current circuits must not lead to unin-
tentional start-up or dangerous movements of a machine, or
prevent its shut-down. In order to fulfill this requirement, one
side of the control current circuits should be connected to the
protective conductor system, with the coils and switching ele-
ments mounted accordingly.
An insulation monitoring device must be planned for control cur-
rent circuits that are supplied by a transformer but not connec-
ted to the protective conductor system. The device should
report an earth fault or automatically disconnect the circuit follo-
wing an earth fault.
(VDE 01136.2.2)
Our earth test/disconnect terminals have been specially desi-
gned for use in control circuits. They have been designed to
guarantee both a reliable and safe disconnection of the earth
connection as well as to indicate the exact operating status.
This terminal differentiates between the following modes of ope-
ration:
Dimensions
Connection data
VDE rated data
Ordering data
Accessories
2
2
for TS 35 W
for TS 32 Y
)
)
2
2
)
)
mm
19/27
55/82
12
0.5…10 mm
0.5…6 mm
AWG 20…8
20…30 V~
10…15 V–
27 A
6 mm
SAKT E KrG
1158720000
SAKT E/35 KrG
1166820000
TS 32
TS 35
EWK 1
EW 35
SAKT E/SAKA 10
Type
2
2
/10 mm
2
/16 mm
40…60 V~
20…30 V–
27 A/47 A
6/10 mm
SAKT E KrG
0699020000
SAKT E/35 KrG
0197920000
SAKA 10
(24 V~)
1174920000
SAKA 10
(24 V–)
8150150000
Cat. No.
0122800000
0383400000
0206160000
0383560000
2
2
2
1. Operating mode
In the operating mode, the control circuit is securely connected
to earth via the closed slide link. A possible earth fault can be
detected with the help of a fuse or an r.c.c.b., because in the
event of a fault the leakage current can be discharged to earth.
2. Test mode
In this mode, it possible to check the isolation status of the
installation. The earth connection must be disconnected for iso-
lation measurements with voltages greater than the rated volta-
ge of the earth conductor disconnect unit.
3. Fault mode
If an earth fault occurs during operation in an earthed control
circuit, our earth conductor disconnect unit make it possible to
switch to a non-earthed control circuit. This bridges the time
required to correct the fault, i.e. the machine can continue to
operate.
80…120 V~
40…60 V–
27 A
6 mm
SAKT E KrG
0699220000
SAKT E/35 KrG
0198220000
2
115 V~
115 V–
27 A/47 A
6/10 mm
SAKT E KrG
0698920000
SAKT E/35 KrG
0198020000
SAKA 10
(115 V~)
1128820000
Qty.
50
50
2
230 V~
230 V–
27 A/47 A
6/10 mm
SAKT E KrG
0606820000
SAKT E/35 KrG
0198120000
SAKA 10
(only 230 V~)
1175020000
SAKA 10
(230 V~)
8109130000
2

Related parts for 1013700000