B32653A4334J EPCOS Inc, B32653A4334J Datasheet
B32653A4334J
Specifications of B32653A4334J
Related parts for B32653A4334J
B32653A4334J Summary of contents
Page 1
... Film Capacitors Metallized Polypropylene Film Capacitors (MKP) Series/Type: B32651 ... B32656 Date: August 2004 © EPCOS AG 2004. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Associ- ation), unless otherwise agreed ...
Page 2
... Metallized polypropylene film capacitors (MKP) High pulse (wound) Typical applications TV (S-correction/flyback) Electronic ballasts Climatic Max. operating temperature: 105 C Climatic category (IEC 60068-1): 55/100/56 Construction Dielectric: polypropylene (PP) Wound capacitor technology with internal series connection for V 1250 VDC R Plastic case (UL 94 V-0) Epoxy resin sealing ...
Page 3
Overview of available types Lead spacing Type B32651 B32652 Page (VDC) 1250 250 R V (VAC) 450 160 rms C (nF) R 1.0 1.5 2.2 3.3 4.7 6 ...
Page 4
B32651 ... B32656 High pulse (wound) Overview of available types Lead spacing 22.5 mm Type B32653 Page 9 V (VDC) 250 400 630 1000 1250 1600 2000 2000 250 400 630 1000 1250 1600 2000 R V (VAC) 160 200 ...
Page 5
Overview of available types Lead spacing 37.5 mm Type B32656 Page 12 V (VDC) 850 R V (VAC) 450 rms C (nF) R 100 150 220 330 470 680 1000 High pulse (wound) 1000 1250 500 500 5 B32651 ... ...
Page 6
B32651 High pulse (wound) Ordering codes and packing units (lead spacing 10 mm Max. dimensions R rms kHz w VDC 1) VAC nF mm 1250 450 2.2 4.0 3.3 5.0 4.7 5.0 6.8 6.0 ...
Page 7
Ordering codes and packing units (lead spacing 15 mm Max. dimensions R rms kHz w VDC VAC nF mm 250 160 150 5.0 220 6.0 330 7.0 470 8.5 680 9.0 5.0 400 200 ...
Page 8
B32652 High pulse (wound) Ordering codes and packing units (lead spacing 15 mm Max. dimensions R rms kHz w VDC VAC nF mm 1600 500 3.3 5.0 4.7 6.0 6.8 7.0 10 8.5 15 ...
Page 9
Ordering codes and packing units (lead spacing 22.5 mm Max. dimensions R rms kHz w VDC VAC nF mm 250 160 220 6.0 330 6.0 470 7.0 680 8.5 1000 10.5 6.0 400 200 ...
Page 10
B32653 High pulse (wound) Ordering codes and packing units (lead spacing 22.5 mm Max. dimensions R rms kHz w VDC VAC nF mm 1600 500 6.8 6.0 10 6.0 15 7.0 22 8.5 33 ...
Page 11
Ordering codes and packing units (lead spacing 27.5 mm Max. dimensions R rms kHz w VDC VAC nF mm 250 160 1500 11.0 2200 12.5 3300 15.0 4700 18.0 11.0 400 200 1000 12.5 ...
Page 12
B32656 High pulse (wound) Ordering codes and packing units (lead spacing 37.5 mm Max. dimensions R rms kHz w VDC VAC nF mm 850 450 220 12.0 330 12.0 470 12.0 680 16.0 1000 ...
Page 13
Technical data Operating temperature range Dissipation factor tan ( (upper limit values) Insulation resistance R ins or time constant = ins rel. humidity 65% (minimum as-delivered values) ...
Page 14
B32651 ... B32656 High pulse (wound) Pulse handling capability "dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal voltages, expressed "k " represents the maximum permissible pulse characteristic of the waveform applied to ...
Page 15
Lead spacing rms VDC VAC 250 160 400 200 630 250 850 450 1000 250 500 25 000 000 1250 450 500 1600 500 600 ...
Page 16
B32651 High pulse (wound) Permissible AC voltage V versus frequency f (for sinusoidal waveforms, T rms For T >90 C, please refer to "General technical information", section 3.2.3. A Lead spacing 10 mm 1250 VDC/450 VAC ...
Page 17
Permissible AC voltage V versus frequency f (for sinusoidal waveforms, T rms For T >90 C, please refer to "General technical information", section 3.2.3. A Lead spacing 15 mm 250 VDC/160 VAC 630 VDC/250 VAC B32652 High pulse (wound) 400 ...
Page 18
B32652 High pulse (wound) Permissible AC voltage V versus frequency f (for sinusoidal waveforms, T rms For T >90 C, please refer to "General technical information", section 3.2.3. A Lead spacing 15 mm 1250 VDC/500 VAC 1600 VDC/700 VAC 1600 ...
Page 19
Permissible AC voltage V versus frequency f (for sinusoidal waveforms, T rms For T >90 C, please refer to "General technical information", section 3.2.3. A Lead spacing 22.5 mm 250 VDC/160 VAC 630 VDC/250 VAC B32653 High pulse (wound) 400 ...
Page 20
B32653 High pulse (wound) Permissible AC voltage V versus frequency f (for sinusoidal waveforms, T rms For T >90 C, please refer to "General technical information", section 3.2.3. A Lead spacing 22.5 mm 1250 VDC/500 VAC 2000 VDC/700 VAC 1600 ...
Page 21
Permissible AC voltage V versus frequency f (for sinusoidal waveforms, T rms For T >90 C, please refer to "General technical information", section 3.2.3. A Lead spacing 27.5 mm 250 VDC/160 VAC 630 VDC/250 VAC B32654 High pulse (wound) 400 ...
Page 22
B32654 High pulse (wound) Permissible AC voltage V versus frequency f (for sinusoidal waveforms, T rms For T >90 C, please refer to "General technical information", section 3.2.3. A Lead spacing 27.5 mm 1250 VDC/500 VAC 2000 VDC/700 VAC 1600 ...
Page 23
Permissible AC voltage V versus frequency f (for sinusoidal waveforms, T rms For T >90 C, please refer to "General technical information", section 3.2.3. A Lead spacing 37.5 mm 850 VDC/450 VAC 1250 VDC/500 VAC B32656 High pulse (wound) 1000 ...
Page 24
B32656 High pulse (wound) Permissible AC voltage V versus frequency f (for sinusoidal waveforms, T rms For T >90 C, please refer to "General technical information", section 3.2.3. A Lead spacing 37.5 mm 2000 VDC/700 VAC ...
Page 25
Flyback application Permissible voltage and current / waveform Permissible current I versus frequency f for a duty cycle of 20 Approximation formular for duty cycle higher than 20%: B32651 ... B32656 High pulse (wound 0.2): 0 ...
Page 26
B32651 ... B32656 High pulse (wound) Flyback application Permissible current I versus rated capacitance C pp Frequency = 15.75 kHz Frequency = 95 kHz R Frequency = 31.5 kHz 26 ...
Page 27
S-correction application Permissible voltage and current / waveform B32651 ... B32656 High pulse (wound) 27 ...
Page 28
B32651 ... B32656 High pulse (wound) S-correction application Permissible current I versus rated capacitance C pp Frequency = 15.75 kHz Frequency = 95 kHz R Frequency = 31.75 kHz 28 ...