FLT-100V10 Murata Power Solutions Inc, FLT-100V10 Datasheet

POWER LINE FILTER, 10A

FLT-100V10

Manufacturer Part Number
FLT-100V10
Description
POWER LINE FILTER, 10A
Manufacturer
Murata Power Solutions Inc
Datasheet

Specifications of FLT-100V10

Input Voltage Min
0VDC
Peak Reflow Compatible (260 C)
No
Output Current
10A
Output Current 1
10A
Leaded Process Compatible
No
Input Voltage Max
100VDC
Mounting Type
PC Board Surface Mount
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
This product is not RoHS compliant.
Features
Compatible with most modern switching
DC/DC converters
Provides both common-mode and
differential-mode fi ltering
Facilitates compliance with all conducted-
emissions specifi cations
Small size; PCB mountable
–40 to +100°C (case) operation
UL94V-0 rated package material
UL approved
Lucent FLTR100V10/20 compatible
+INPUT
+INPUT
–INPUT
–INPUT
–INPUT
+INPUT
www.murata-ps.com
system-level designs, designers often apply these standards at the component level
to ensure system-level compliance. For those DC/DC converters that do not meet
these standards, DATEL offers the FLT-100V Series EMI fi lters. When used with the
recommended external capacitors, this family of fi lters signifi cantly reduces both the
common-mode and differential emissions injected back to the power source.
0.5" (FLT-100V10) and 1.6" x 2" x 0.5" (FLT-100V20) packages. Components and
the pcb are coated with a humidity-sealing conformal coating and then encapsulated
with a thermally conductive potting compound providing outstanding moisture/vibra-
tion resistance. Both fi lters are rated for 100Vdc differential input voltage and are
internally bypassed with a telecom/datacom preferred mylar, self-healing, 100Vdc
rated capacitor. Input-to-GND and Output-to-GND isolation voltages are guaranteed
at 1500Vdc. Inductor copper losses and pcb trace losses are minimized to attain a
low Input-to-Output per leg resistance of 9.5mΩ for FLT-100V10 and 4.8mΩ for FLT-
100V20 when measured at +25°C. Both Filters are fully characterized to 20MHz for
both common-mode and differential-mode dynamic insertion losses. The FLT-100V
series EMI fi lters are UL approved.
Although agency-imposed conducted-emissions standards are targeted for
These rugged fi lters are packaged in non-conductive, UL94V-0 rated, 1" x 2" x
Figure 1. Simplifi ed Schematics
GROUND
GROUND
Filter Modules, 100Vdc, 10 Amp and 20 Amp
Model FLT-100V10
Model FLT-100V20
OBSOLESCENCE
–OUTPUT
+OUTPUT
Technical enquiries email: sales@murata-ps.com, tel:
TARGETED FOR
Differential/Common-Mode Filters
MMP_FLT10-20-Series.B03 Page 1 of 7
+OUTPUT
+OUTPUT
–OUTPUT
–OUTPUT
FLT Series
+1 508 339 3000

Related parts for FLT-100V10

FLT-100V10 Summary of contents

Page 1

... Input-to-GND and Output-to-GND isolation voltages are guaranteed at 1500Vdc. Inductor copper losses and pcb trace losses are minimized to attain a low Input-to-Output per leg resistance of 9.5mΩ for FLT-100V10 and 4.8mΩ for FLT- 100V20 when measured at +25°C. Both Filters are fully characterized to 20MHz for both common-mode and differential-mode dynamic insertion losses. The FLT-100V series EMI fi ...

Page 2

... A ➁ 50Ω load @ 500kHz FLT - 100V10 Filter Module Series 100V10 = 100 Volt input 10 Amp rating 100V20 = 100 Volt input 20 Amp rating Model FLT-100V10 2.00 (50.80) 0.48 Case F1 (12.19) 0.031 ±0.001 DIA. (0.787 ±0.025) 0.20 MIN (5.08) 1.700 (43.18) 0.475 (12.07) ...

Page 3

... Description The FLT-100V series of passive fi lters are optimized to reduce both common- mode and differential-mode noise on both input and output lines of switching DC/DC converters. The FLT-100V10 is rated for 10A of continuous current while the FLT-100V20 is rated for 20A. Differential-mode and Common-mode Noise Designers who are faced with reducing conducted emissions in DC/DC applications must address both differential-mode and common-mode noise ...

Page 4

... Differential/Common-Mode Filters BWR-5/6-3.3/7-D12 Conducted Emissions EN 55022 Class A Limit EN 55022 Class B Limit Conducted Emissions 1.0 Frequency (MHz) BWR-5/6-3.3/7-D12 Conducted Emissions Using FLT-100V10 Filter EN 55022 Class A Limit EN 55022 Class B Limit Conducted Emissions 1.0 Frequency (MHz) Technical enquiries email: sales@murata-ps.com, tel: MMP_FLT10-20-Series.B03 Page 10.0 10 ...

Page 5

... COMMON –INPUT OUTPUT –5V OUT GND 10μF Figure 5. Using FLT-100V10 as an Output Filter for Bipolar DC/DC Output Ripple and Noise of BWR-5/700-D48A (No external capacitance.) 20mV/div, 20MHz Bandwidth Output Ripple and Noise of BWR-5/700-D48A (Using single leg of FLT-100V10 and 10μF capacitance.) 20mV/div, 20MHz Bandwidth Technical enquiries email: sales@murata-ps ...

Page 6

... Frequency (MHz) Typical Common-Mode Insertion Loss Curves FLT-100V10 Common-Mode Insertion Loss ( Into 50 Ohm Load) 0 –10 –20 –30 –40 –50 –60 –70 –80 0.001 0.010 0.100 1.000 Frequency (MHz) www ...

Page 7

... Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com © 2008 Murata Power Solutions, Inc. 05/06/08 www.murata-ps.com FLT Series Filter Modules, 100Vdc, 10 Amp and 20 Amp Differential/Common-Mode Filters Technical enquiries email: sales@murata-ps.com, tel: MMP_FLT10-20-Series.B03 Page 508 339 3000 ...