FLT-100V10 Murata Power Solutions Inc, FLT-100V10 Datasheet
FLT-100V10
Specifications of FLT-100V10
Related parts for FLT-100V10
FLT-100V10 Summary of contents
Page 1
... Input-to-GND and Output-to-GND isolation voltages are guaranteed at 1500Vdc. Inductor copper losses and pcb trace losses are minimized to attain a low Input-to-Output per leg resistance of 9.5mΩ for FLT-100V10 and 4.8mΩ for FLT- 100V20 when measured at +25°C. Both Filters are fully characterized to 20MHz for both common-mode and differential-mode dynamic insertion losses. The FLT-100V series EMI fi ...
Page 2
... A ➁ 50Ω load @ 500kHz FLT - 100V10 Filter Module Series 100V10 = 100 Volt input 10 Amp rating 100V20 = 100 Volt input 20 Amp rating Model FLT-100V10 2.00 (50.80) 0.48 Case F1 (12.19) 0.031 ±0.001 DIA. (0.787 ±0.025) 0.20 MIN (5.08) 1.700 (43.18) 0.475 (12.07) ...
Page 3
... Description The FLT-100V series of passive fi lters are optimized to reduce both common- mode and differential-mode noise on both input and output lines of switching DC/DC converters. The FLT-100V10 is rated for 10A of continuous current while the FLT-100V20 is rated for 20A. Differential-mode and Common-mode Noise Designers who are faced with reducing conducted emissions in DC/DC applications must address both differential-mode and common-mode noise ...
Page 4
... Differential/Common-Mode Filters BWR-5/6-3.3/7-D12 Conducted Emissions EN 55022 Class A Limit EN 55022 Class B Limit Conducted Emissions 1.0 Frequency (MHz) BWR-5/6-3.3/7-D12 Conducted Emissions Using FLT-100V10 Filter EN 55022 Class A Limit EN 55022 Class B Limit Conducted Emissions 1.0 Frequency (MHz) Technical enquiries email: sales@murata-ps.com, tel: MMP_FLT10-20-Series.B03 Page 10.0 10 ...
Page 5
... COMMON –INPUT OUTPUT –5V OUT GND 10μF Figure 5. Using FLT-100V10 as an Output Filter for Bipolar DC/DC Output Ripple and Noise of BWR-5/700-D48A (No external capacitance.) 20mV/div, 20MHz Bandwidth Output Ripple and Noise of BWR-5/700-D48A (Using single leg of FLT-100V10 and 10μF capacitance.) 20mV/div, 20MHz Bandwidth Technical enquiries email: sales@murata-ps ...
Page 6
... Frequency (MHz) Typical Common-Mode Insertion Loss Curves FLT-100V10 Common-Mode Insertion Loss ( Into 50 Ohm Load) 0 –10 –20 –30 –40 –50 –60 –70 –80 0.001 0.010 0.100 1.000 Frequency (MHz) www ...
Page 7
... Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com © 2008 Murata Power Solutions, Inc. 05/06/08 www.murata-ps.com FLT Series Filter Modules, 100Vdc, 10 Amp and 20 Amp Differential/Common-Mode Filters Technical enquiries email: sales@murata-ps.com, tel: MMP_FLT10-20-Series.B03 Page 508 339 3000 ...