INDUCTOR, 0805 CASE, 680NH

B82498B1681J

Manufacturer Part Number
B82498B1681J
Description
INDUCTOR, 0805 CASE, 680NH
Manufacturer
EPCOS Inc
Datasheets

Specifications of B82498B1681J

Inductance Tolerance
± 5%
Dc Resistance Max
0.5ohm
Dc Current Rating
250mA
Resonant Frequency
450MHz
Q @ Vr F
20
Core Material
Ferrite
Inductor Case Style
0805
No. Of Pins
2
Inductance
680nH
Svhc
No SVHC (18-Jun-2010)
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
B82498B1681J
Manufacturer:
JST
Quantity:
1 750
Part Number:
B82498B1681J
Manufacturer:
EPCOS/爱普科斯
Quantity:
20 000
Part Number:
B82498B1681J000
Manufacturer:
EPCOS
Quantity:
60 000
Part Number:
B82498B1681J000
Manufacturer:
EPCOS/爱普科斯
Quantity:
20 000
1.4.2
In order to be able to choose the correct EMC measures, we need to know the characteristics of the
interferences, how they are propagated and the mechanisms by which they are coupled into the cir-
cuit. In principle, the interferences can also be classified according to their range
quencies, it can be assumed that the interference only spreads along conductive structures, at high
frequencies only by means of electromagnetic radiation. In the MHz frequency range, the term cou-
pling is generally used to describe the mechanism.
Analogously, conducted interference on lines at frequencies of up to several hundred kHz are main-
ly symmetrical ( differential mode ), at higher frequencies, they are asymmetrical ( common mode ).
This is because the coupling factor and the effects of parasitic capacitance and inductance between
the conductors increase with frequency.
X capacitors and single chokes are suitable as suppression measures for the differential mode com-
ponents. Where asymmetrical, i.e. common-mode interference has to be eliminated, current-com-
pensated chokes and Y capacitors are mainly used, the prerequisite for this being, however, a well-
designed, EMC-compliant grounding and wiring system.
The categorization of types of interference and suppression measures and their relation to the fre-
quency ranges is reflected in the frequency limits for interference voltage and interference field
strength measurements.
10
Fig. 2
General Technical Information
_
2
Unsymmetrical interference:
– This term is used to describe interference on a single line, relative to the reference potential
(fig.
Differential mode
1c)
Pc ch.
X cap
Characteristics of interferences
Line
Frequency range overview
Pc ch. = Iron powder core chokes, but also all single chokes/ X cap = X capacitors
Cc ch. = Current-compensated chokes / Y cap = Y capacitors
10
_
1
Interference voltage
Cc ch.
10
Y cap
Common mode
0
Coupling
Ground
10
1
11
Field strength
Shielding
10
Field
Field
2
04/00
f
SSB1558-D
MHz 10
3
Interference
characteristic
Interference
propagation
Remedies
Max. ratings
(fig.
2). At low fre-

Related parts for B82498B1681J