CXA-P1212C-WJL TDK Corporation, CXA-P1212C-WJL Datasheet

CCFL Inverters & Accessories Dimming

CXA-P1212C-WJL

Manufacturer Part Number
CXA-P1212C-WJL
Description
CCFL Inverters & Accessories Dimming
Manufacturer
TDK Corporation
Datasheet

Specifications of CXA-P1212C-WJL

Function
Dimming Inverter
Input Voltage
12 V
Number Of Outputs
2
Output Voltage
1700 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CXA-P1212C-WJL
Manufacturer:
POWERDSIN
Quantity:
43
CXA-P1212C-WJL
■ Features
Electrical Characteristics
(*1) Please refer to the connection diagram for details of a dimming method.
(*2) Please refer to the connection diagram for details of alarm output.
(*3) As equivalent circuit of panel load, connect resistance load (RL) and distributed capacity (CL), and have provided by an electrical characteristic.
Other Specifications
(*4) These dimensions are indicated the maximum.
All specifications are subject to change without notice.
Item
Output Current mArms
Input Current
Frequency
Open Circuit Voltage Vrms
Alarm Signal
Dimming Function
Operating Temperature ℃
Storage Temperature ℃
Operating Humidity Ratio RH%
Safety Standard
Weight
Dimensions(WxDxH) mm
Fused Input
Remote ON / OFF
Alarm Signal Function
Shutdown Function
Silicone Coating on
High Voltage Area
● 2-output
●UL60950 approved
●Applicable panel size*: 10 to 12 inches
●With brightness control function (Pulse Wide Modulation mode).
●With shut down function.
●With a sensing function for running out of lamp (alarm output).
●In the high-voltage generator(a terminal and a pattern),
(Notice) Applicable panel size becomes a standard.
an anti-dust measure by silicone application is taken.
CXA-P1212C-WJL Specifications
Unit
A
mA
kHz
Hz
V
g
Symbol
Iout
(Maximum dimmer)
Iout
(Minimum dimmer)
Iin1
Iin2
Freq1
Freq2 (Duty frequency)
Vopen
Vst
153.5x22x8.5 (*4)
1500
220
min
5.5
5.5
5.3
5.3
4.5
1.2
1.2
1.1
1.1
38
-
-
-30 to +85
-10 to +70
UL60950
Specifi cation
95Max
-
Yes
Yes
Yes
Yes
Yes
Yes
20
1700
250
6.0
6.0
6.0
6.0
2.0
2.0
2.0
2.0
0.8
5.0
typ
43
0
max
280
6.5
6.5
6.7
6.7
2.8
2.8
2.9
2.9
1.0
5.5
0.5
48
1
-
10.8min.
12 0.6
12 0.6
12 1.2
12 1.2
12 0.6
12 0.6
12 1.2
12 1.2
12 0.6
12 0.6
12 0.6
12 1.2
12 1.2
12 1.2
Vin(V) Vrmt(V) Vbr(V)
■ Applications
5
5
5
5
5
5
5
5
5
5
5
5
5
5
(Please refer to each specification before use)
This means that, in conformity with EU Directive
2002/95/EC, lead, cadmium, mercury, hexavalent
chromium, and specific bromine-based flame
retardants, PBB and PBDE, have not been used,
except for exempted applications.
■ Conformity to RoHs Directive
2.5
2.5
2.5
0
0
0
-
-
-
-
0
0
0
0
0
Condition
Rbr(kΩ)
Dimming/Connector Type
50
50
50
0
0
-
-
-
-
-10 to +70 85 to 95
-10 to +70 85 to 95
-10 to +70 85 to 95
-10 to +70 85 to 95
-10 to +70
-10 to +70 85 to 95
-10 to +70 85 to 95
-10 to +70 85 to 95
-10 to +70
-10 to +70
-10 to +70 85 to 95
Ta(℃ )
23 5
23 5
23 5
23 5
001-01/20080228/etl_cxa_p1212c_wjl
85 to 95
85 to 95
RL(kΩ) CL(pF)(*3)
90
90
90
5
5
5
5
5
5
5
5
5
5
5
5
5
Voltage dimmer (*1)
Voltage dimmer (*1)
Voltage dimmer (*1)
Voltage dimmer (*1)
In case of lamp anomaly (*2)
Volume dimmer (*1)
Volume dimmer (*1)
Volume dimmer (*1)
Volume dimmer (*1)
On a normal operation (*2)
Remote OFF
Remote ON
Open load
Remark
1

Related parts for CXA-P1212C-WJL

CXA-P1212C-WJL Summary of contents

Page 1

... Wide Modulation mode). ●With shut down function. ●With a sensing function for running out of lamp (alarm output). ●In the high-voltage generator(a terminal and a pattern), an anti-dust measure by silicone application is taken. (Notice) Applicable panel size becomes a standard. CXA-P1212C-WJL Specifications Electrical Characteristics Item Unit Symbol min 5 ...

Page 2

... CXA-P1212C-WJL ※From high-voltage generator, please secure space distance more than 3mm in top and bottom right and left. Connector Connector Part number Model/Material number ① Printed circuit board PCB Composite (CEM-3) ② Input connector CN1 53261-0771 ③ Output connector CN2 SM03 (7-D1) B-BHS-1-TB (LF) ...

Page 3

... CXA-P1212C-WJL 12±1.2V Operate as follows by switching SW1. SW1 Unit operation a Operation b Does not operate Open Does not operate Protection circuit operation Alarm output Load condition ※1 (CN1-6 ) In load normal 0.5V max. When 1 load 5 0.5V (lamp) is run-out When 2 loads 5 0.5V (lamps) are run-out ※ ...

Related keywords