CXA-P1212C-WJL
■ Features
Electrical Characteristics
(*1) Please refer to the connection diagram for details of a dimming method.
(*2) Please refer to the connection diagram for details of alarm output.
(*3) As equivalent circuit of panel load, connect resistance load (RL) and distributed capacity (CL), and have provided by an electrical characteristic.
Other Specifications
(*4) These dimensions are indicated the maximum.
All specifications are subject to change without notice.
Item
Output Current mArms
Input Current
Frequency
Open Circuit Voltage Vrms
Alarm Signal
Dimming Function
Operating Temperature ℃
Storage Temperature ℃
Operating Humidity Ratio RH%
Safety Standard
Weight
Dimensions(WxDxH) mm
Fused Input
Remote ON / OFF
Alarm Signal Function
Shutdown Function
Silicone Coating on
High Voltage Area
● 2-output
●UL60950 approved
●Applicable panel size*: 10 to 12 inches
●With brightness control function (Pulse Wide Modulation mode).
●With shut down function.
●With a sensing function for running out of lamp (alarm output).
●In the high-voltage generator(a terminal and a pattern),
(Notice) Applicable panel size becomes a standard.
an anti-dust measure by silicone application is taken.
CXA-P1212C-WJL Specifications
Unit
A
mA
kHz
Hz
V
g
Symbol
Iout
(Maximum dimmer)
Iout
(Minimum dimmer)
Iin1
Iin2
Freq1
Freq2 (Duty frequency)
Vopen
Vst
153.5x22x8.5 (*4)
1500
220
min
5.5
5.5
5.3
5.3
4.5
1.2
1.2
1.1
1.1
38
-
-
-30 to +85
-10 to +70
UL60950
Specifi cation
95Max
-
Yes
Yes
Yes
Yes
Yes
Yes
20
1700
250
6.0
6.0
6.0
6.0
2.0
2.0
2.0
2.0
0.8
5.0
typ
43
0
max
280
6.5
6.5
6.7
6.7
2.8
2.8
2.9
2.9
1.0
5.5
0.5
48
1
-
10.8min.
12 0.6
12 0.6
12 1.2
12 1.2
12 0.6
12 0.6
12 1.2
12 1.2
12 0.6
12 0.6
12 0.6
12 1.2
12 1.2
12 1.2
Vin(V) Vrmt(V) Vbr(V)
■ Applications
5
5
5
5
5
5
5
5
5
5
5
5
5
5
(Please refer to each specification before use)
This means that, in conformity with EU Directive
2002/95/EC, lead, cadmium, mercury, hexavalent
chromium, and specific bromine-based flame
retardants, PBB and PBDE, have not been used,
except for exempted applications.
■ Conformity to RoHs Directive
2.5
2.5
2.5
0
0
0
-
-
-
-
0
0
0
0
0
Condition
Rbr(kΩ)
Dimming/Connector Type
50
50
50
0
0
-
-
-
-
-10 to +70 85 to 95
-10 to +70 85 to 95
-10 to +70 85 to 95
-10 to +70 85 to 95
-10 to +70
-10 to +70 85 to 95
-10 to +70 85 to 95
-10 to +70 85 to 95
-10 to +70
-10 to +70
-10 to +70 85 to 95
Ta(℃ )
23 5
23 5
23 5
23 5
001-01/20080228/etl_cxa_p1212c_wjl
85 to 95
85 to 95
RL(kΩ) CL(pF)(*3)
90
90
90
∞
∞
5
5
5
5
5
5
5
5
5
5
5
5
5
Voltage dimmer (*1)
Voltage dimmer (*1)
Voltage dimmer (*1)
Voltage dimmer (*1)
In case of lamp anomaly (*2)
Volume dimmer (*1)
Volume dimmer (*1)
Volume dimmer (*1)
Volume dimmer (*1)
On a normal operation (*2)
Remote OFF
Remote ON
Open load
Remark
1