4171700XX-3 Digital View Inc, 4171700XX-3 Datasheet - Page 14

no-image

4171700XX-3

Manufacturer Part Number
4171700XX-3
Description
Display Modules & Development Tools SVH-1920+ CONTROLLER
Manufacturer
Digital View Inc
Datasheets

Specifications of 4171700XX-3

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Summary: Jumpers setting
Specifications subject to change without notice
© Digital View Ltd – Doc Ver 1.1: 8 Nov, 2010 (SVH-1920+_manual.doc)
SW3
SW4
JA2
JA3
JA5
JA6
JB2
JB3
JB5
JC1
JC2
JP6
Ref
JT1
JT2
JT3
JT4
JT5
JT6
JT7
JT8
On board +3.3V logic power enable
Panel power voltage select
CAUTION: Incorrect setting can damage
panel
Panel power voltage select
CAUTION: Incorrect setting will cause panel
damage
Panel power voltage select
CAUTION: Incorrect setting will cause panel
damage
Backlight inverter on/off control – signal level
Backlight inverter on/off control – polarity
Backlight control type selection
Custom configuration
Custom configuration
Input power control
S-Video Chroma -in terminator enable
S-Video luma-in terminator enable
Composite video-in terminator enable
Component luma-in terminator enable
Component Cb/Pb-in terminator enable
Component Cr/Pr-in terminator enable
Composite video 2-in terminator enable
Reserved
Panel & function selection
Panel & function selection
Purpose
1-2 & 3-4 closed, factory set, do not remove
See panel voltage setting table 1
See panel voltage setting table 1
See panel voltage setting table 1
2-3 = On/Off control signal ‘High’ = +5V
1-2 = On/Off control signal ‘High’ = +3.3V
Open = On/Off control signal ‘High’ = Open collector
CAUTION: Incorrect setting can damage inverter.
1-2 = control signal ‘high’ = CCFT ON
2-3 = control signal ‘low’ = CCFT ON
1-2 = VR/Digital switch mount control
3-4 = Analog backlight brightness - voltage range 0~5V
5-6 = PWM (Pulse Width Modulation) brightness
Position 2 :
Closed = Enable save Current Settings as Calibrated
Values on OSD menu
Position 3 :
Closed = Enable baud rate selection function in
programming mode
Position 4 :
Closed = Hide “Reset to Factory Defaults” and “Reset to
Factory Defaults with (Color Temp.)” from OSD menu.
Position 1 : Enable J3 – pin 5 (OP1) controlled by JB4
Position 2 : Enable J3 – pin 6 (OP2) controlled by JB4
Position 3 : Enable J3 – pin 21 (OP3) controlled by JB4
Position 4 : Enable J3 – pin 22 (OP4) controlled by JB4
Short = External switch control
Open = Switch mount control
Open = S-video chroma input is not terminated
Close = S-video chromainput is terminated with 75Ω
Open = S-video luma input is not terminated
Close = S-video luma input is terminated with 75Ω
Open = composite input is not terminated
Close = composite input is terminated with 75Ω
Open = component luma input is not terminated
Close = component luma input is terminated with 75Ω
Open = component Cb/Pb input is not terminated
Close = component Cb/Pb input is terminated with 75Ω
Open = component Cr/Pr input is not terminated
Close = component Cr/Pr input is terminated with 75Ω
Open = composite video 2 input is not terminated
Close = composite video 2 input is terminated with 75Ω
Reserved
See table 2
See table 3
Note
Page
14 of 55

Related parts for 4171700XX-3