324544 Tyco Electronics, 324544 Datasheet - Page 13

no-image

324544

Manufacturer Part Number
324544
Description
CONN SPLICE BUTT 20-24 AWG
Manufacturer
Tyco Electronics
Series
Certi-Seal™r
Datasheets

Specifications of 324544

Terminal Type
Butt Splice, Inline, Individual Openings
Number Of Wire Entries
2
Termination
Crimp
Wire Gauge
20-24 AWG
Insulation
Fully Insulated
Color
Natural
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
6. VISUAL AID
Figure 11 shows a typical application of PIDG terminals, splices, and end caps. This illustration should be used
by production personnel to ensure a correctly applied terminal, splice, or end cap. Applications which DO NOT
appear correct should be inspected using the information in the preceding pages of this specification and in the
instructional material shipped with the product or tooling.
IF APPLICABLE, DOT CODE MUST BE
WELL FORMED AND CORRESPOND
WITH WIRE SIZE MARKING ON TOOLING
Rev
PIDG Terminals, Splices, and End Caps
E
TERMINAL, SPLICE, OR END CAP
MUST BE STRAIGHT AND NOT
TWISTED ALONG AXIS
WIRE INSULATION MUST BE INSIDE
METAL SLEEVE OF TERMINAL,
SPLICE, OR END CAP
CRIMP MUST BE EVENLY
FORMED ACROSS CENTER
OF WIRE BARREL
FIGURE 11. VISUAL AID (CONT’D)
INSULATION OF TERMINAL, SPLICE, OR END CAP
MUST BE FORMED OVER WIRE INSULATION
Tyco Electronics Corporation
WIRE MUST BE VISIBLE
AT END OF WIRE BARREL
EACH WIRE MUST BE FLUSH
TO END OF WIRE BARREL
OR BOTTOMED ON STOP
INSULATION OF TERMINAL, SPLICE, OR END CAP
MUST BE EVENLY FORMED WITHOUT
OVERSTRESS MARKS
FRONT BELLMOUTH
MUST BE EVIDENT
INSULATION OF TERMINAL, SPLICE, OR
END CAP MUST NOT BE CUT OR TORN
WIRE MUST BE BOTTOMED
IN END CAP
END OF TERMINAL, SPLICE, OR
END CAP MUST NOT
BE BENT OR DEFORMED
114-2157
13
of 14

Related parts for 324544