E3S-LS10XE4 Omron, E3S-LS10XE4 Datasheet
E3S-LS10XE4
Specifications of E3S-LS10XE4
Available stocks
Related parts for E3S-LS10XE4
E3S-LS10XE4 Summary of contents
Page 1
... Sensing of objects utilizing their difference in luster. E3S-LS20X Sensing of objects utilizing their difference in luster. É É É Sensing distance cm Sensing distance NPN output E3S-LS20XE4 E3S-LS10XE4 E3S-LS3C1D E3S-LS3RC4 Sensing of objects traveling in contiguous succession. Pencils Sensing of objects traveling in contiguous succession. Supply voltage Output VDC 80 mA ...
Page 2
... Wire-selectable (Refer to “Output Circuit.”) Light indicator (red), stability indicator (green) Short circuit Provided IP67 Metal Red LED Infrared LED Operating: – °C E3S-LS E3S-LS3C1D E3S-LS3RC4 5 VDC –10 VDC –10 VDC +10%, 24 VDC +10%, ripple (p-p): 10% max. ripple (p-p): 10% max. 3±0.5 cm --- white mat paper 30 mA max ...
Page 3
... Sensitivity adjustor: Set to MAX. Note: 2. This graph shows the relationship between the optical output and setting distance by adjusting the sensitivity adjustor so that the optical output will be maximum at a sensing distance cm. E3S-LS10XE4 Optical axis Standard object (1 × 1 cm) Operating distance x Distance Distance ...
Page 4
... E3S-LS10X -E4 Type (NPN Output) Main circuit E3S-LS20X -E4 Type (NPN Output) Main circuit E3S-LS3C1D +V Operation indicator (red) OUT Photoelectric sensor main circuit Zener diode (V E3S-LS3RC4 Light-ON +V Incident indicator OUT (red) Photoelectric sensor main 0 V circuit 4 -B4 Type (PNP Output) Light- Dark Brown ...
Page 5
... OFF -B4 Type (PNP Output) Dark-ON Incident Light Interrupted LIGHT ON indicator OFF Output Operates transistor Releases Load ON (relay, etc.) OFF E3S-LS3RC4 Light-ON Incident Light Interrupted LIGHT ON indicator OFF Output ON transistor OFF Load Operates (relay, etc.) Releases (Between brown and black lines) ...
Page 6
... Standard length Weight: approx Indicator Lens (14 x 47) (A) (See note) Emitter Optical axis Receiver Two 4.4 dia. holes E3S-LS3C1D Timer Volume Indicator E3S-LS3RC4 Sensitivity Adjustor Optical axis Optical axis E3S-LS Distance adjustor Sensitivity adjustor Mounting Holes Two holes 8 dia. ...
Page 7
... E3S-LS Precautions Sensing Distance Adjustment E3S-LS10XE4 Adjustment Method 1. Set the pointer of the sensitivity adjuster to the center of its revolution range. 2. Turn the distance adjuster fully counterclockwise to the “S” position. 3. Set the sensing object in position. 4. Turn the distance adjuster gradually clockwise to a point where both the LIGHT and STABILITY indicators light ...
Page 8
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...