SFH 309 FA-5 OSRAM Opto Semiconductors Inc, SFH 309 FA-5 Datasheet - Page 7

Photodetector Transistors PHOTOTRANSISTOR

SFH 309 FA-5

Manufacturer Part Number
SFH 309 FA-5
Description
Photodetector Transistors PHOTOTRANSISTOR
Manufacturer
OSRAM Opto Semiconductors Inc
Type
IR Chipr
Datasheet

Specifications of SFH 309 FA-5

Maximum Power Dissipation
165 mW
Maximum Dark Current
200 nA
Fall Time
8 us
Maximum Operating Temperature
+ 100 C
Minimum Operating Temperature
- 40 C
Rise Time
8 us
Package / Case
T-1
Phototransistor Type
Phototransistor
Polarity
NPN
Number Of Elements
1
Collector-emitter Voltage
35V
Collector Current (dc) (max)
15mA
Collector-emitter Sat Volt (max)
0.2V
Dark Current (max)
200nA
Light Current
7.2mA
Power Dissipation
165mW
Peak Wavelength
900nm
Half-intensity Angle
24deg
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Through Hole
Pin Count
2
Package Type
T-1
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q62702P0180
Lötbedingungen
Soldering Conditions
Wellenlöten (TTW)
TTW Soldering
Published by
OSRAM Opto Semiconductors GmbH
Wernerwerkstrasse 2, D-93049 Regensburg
www.osram-os.com
© All Rights Reserved.
The information describes the type of component and shall not be considered as assured characteristics.
Terms of delivery and rights to change design reserved. Due to technical requirements components may contain
dangerous substances. For information on the types in question please contact our Sales Organization.
Packing
Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office.
By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing
material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs
incurred.
Components used in life-support devices or systems must be expressly authorized for such purpose! Critical
components
1
to cause the failure of that life-support device or system, or to affect its safety or effectiveness of that device or system.
2
and sustain human life. If they fail, it is reasonable to assume that the health of the user may be endangered.
2007-04-02
A critical component is a component usedin a life-support device or system whose failure can reasonably be expected
Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain
T
300
250
200
150
100
50
C
0
0
1
235 C
100
, may only be used in life-support devices or systems
C
... 260
... 130
C
C
ca 200 K/s
1. Welle
1. wave
50
2 K/s
10 s
Zwangskühlung
forced cooling
5 K/s
100
2. Welle
2. wave
7
(nach CECC 00802)
(acc. to CECC 00802)
2
2 K/s
with the express written approval of OSRAM OS.
150
SFH 309, SFH 309 FA
t
Normalkurve
standard curve
Grenzkurven
limit curves
200
s
OHLY0598
250