950012D MicroSun Technologies, 950012D Datasheet - Page 2

no-image

950012D

Manufacturer Part Number
950012D
Description
Manufacturer
MicroSun Technologies
Datasheet

Specifications of 950012D

Rechargeable/non-rechargeable
Rechargeable
Battery Capacity
1.4Ah
Battery Type
Secondary
Battery Shape
Cylindrical
Number Of Cells
5
Battery Chemistry
Lithium-Ion
Voltage
19.3
Charge Current
1400
Charge Time
1.5hrs
Memory Effect
No
Average Service Life
300Cycle
Product Length (mm)
94mm
Product Depth (mm)
67mm
Product Height (mm)
21mm
Operating Temperature Max Deg. C
45C
Operating Temperature Min Deg. C
0C
Lead Free Status / RoHS Status
RoHS Not Applicable
REVISION
DOCUMENT NUMBER:
 
 
00
4.4 Discharge condition:
4.5 Cycle life: 82% of initial minimum capacity after 300 cycles at 3C, 23°C
4.6 Temperature:
4.7 Products shipped have 40% state of charge typical
  
4.3.2 To charge lithium-ion battery packs please follow the charging instruction stated
Charging instructions
950012D
Cutoff voltage of 15.0 V
Maximum discharge current of 10000mA.
Discharge -20~60°C
Storage -20~20°C
Charge Voltage: Limit the maximum charge voltage to 4.2V times the number of
cells connected in series. This charging voltage is noted on the product
specification sheet.
Charge current: Packs should be charged at C rate for lithium-ion cells. C is the
nominal capacity of the pack. (Example: for a 2400 mAh cell, charge at 2.4A).
Pre-charge: If the cells are deeply depleted (less than 2.9V per cell), packs should
be charged at 10% of their capacity (Example: for a 2400 mAh cell, charge at 240
mA) until reaching 3.0V per cell when charging can be continued as stated above.
Charge temperature: Do not charge lithium ion cells at less than 0°C or more than
45°C.
Reverse polarity: When connecting the cells to a charger, verify proper polarity.
Charge method: Lithium ion cells should be charged using a constant
current/constant voltage (CC/CV) method. Apply the charge current as stipulated
above in step 2 until the pack reaches the voltage measured in step 1. Then, hold
the voltage constant until the current tapers down to about 5% of nominal capacity
(Example: for a 2400 mAh cell, charge until current is 120 mA).
Charge 0~45°C
ECR/ECN INFORMATION
EC No:
DATE:
below:
PRODUCT SPECIFICATION
TITLE:
CREATED/REVISED BY:
19.3V 1400mAh Li-Ion battery
AIE
CHECKED BY
MJS
APPROVED BY
SHEET No.
2 of 3 
MJS

Related parts for 950012D