HET-AW-RLC-A Cooper/Bussmann, HET-AW-RLC-A Datasheet

Fuseholders, Clips, & Hardware In-Line Tron

HET-AW-RLC-A

Manufacturer Part Number
HET-AW-RLC-A
Description
Fuseholders, Clips, & Hardware In-Line Tron
Manufacturer
Cooper/Bussmann
Type
Fuse Holdersr
Datasheet

Specifications of HET-AW-RLC-A

Product
Holder
Current Rating
6.3 Amps
Voltage Rating
250 Volts
Mounting Style
In-Line
Number Of Poles
1
Termination Style
Wire
Size (lxwxh)
12 mm
Lead Free Status / RoHS Status
Not Compliant
Lead Free Status / RoHS Status
Not Compliant
Non-Breakaway Holders
Catalog Symbol: HET-AA, HET-AB, HET-BB, HET-JJ, and
HET-JK
In-Line Fuseholders, Single-Pole
Water-Resistant
HET — A HEB fuseholder with a permanently installed solid
neutral. Easily identified by white plastic coupling nut.
Example:
A single-pole, in-line holder for a neutral is required. One solid
copper #8 is on the load side, copper crimp for connection. A
solid copper #6 is on the line side, and a copper crimp is
required.
1. Choose HET- series.
2. Choose “A” for load side.
3. Choose “B” for line side.
Complete Catalog Number: HET-AB.
Ordering Information:
Recommended Torque on Coupling Nut: 10-20 in-lb.
7-16-03
TRON
Single-Pole for Solid Neutral
For breakaway holders, see page 2
HET
N03082
®
In-Line Fuseholders
Load
Terminal
Line
Terminal
Catalog and Specification Data - Non-Breakaway
Conductor Terminals
Terminal Type
Copper Crimp
Copper Set-Screw
Aluminum Set-Screw
Catalog Data — Insulating Boots
Insulating boots are not included with non-breakaway parts
and must be ordered separately. They come standard with
the breakaway series. The HET-AW & HET-JW do not have
the boots. These catalog items do not have a breakaway recep-
tacle.
When boots are utilized, extra heat retention requires that fuses
are sized at a minimum of 200% of the RMS load current.
Conductors
Size
#12 to #8
#12
#10
#6
#4
#12 to #3
#12 to #2
#12 to #2
Catalog
Numbers
2A0660
2A0661
1
2
2
1
1
1
2
1
Bussmann
Type
Single Conductor
Two Conductor
Form No. HET Series
Series
Data Sheet: 2125
HET
Catalog
Symbol
Load &
(2 & 3)
Page 1 of 2
Line
A
B
K
L
J
®

Related parts for HET-AW-RLC-A

HET-AW-RLC-A Summary of contents

Page 1

... Catalog Data — Insulating Boots Insulating boots are not included with non-breakaway parts and must be ordered separately. They come standard with the breakaway series. The HET-AW & HET-JW do not have the boots. These catalog items do not have a breakaway recep- tacle. When boots are utilized, extra heat retention requires that fuses are sized at a minimum of 200% of the RMS load current ...

Page 2

... A single #10, solid wire and a copper crimp is needed on the line side. 1. Choose HET- series. 2. Choose “A” from 1st page for load side. 3. Choose “W” for breakaway requirement. 4. Choose “RLC-A” for breakaway receptacle on line side. Complete Catalog Number: HET-AW-RLC-A Ordering Information: HET W Load Terminal Recommended Torque on Coupling Nut: 10-20 in-lb ...