HEB-AC Cooper/Bussmann, HEB-AC Datasheet

Fuseholders, Clips, & Hardware In-Line Tron

HEB-AC

Manufacturer Part Number
HEB-AC
Description
Fuseholders, Clips, & Hardware In-Line Tron
Manufacturer
Cooper/Bussmann
Type
Fuse Holdersr
Datasheet

Specifications of HEB-AC

Product
Holder
Current Rating
20 Amps
Voltage Rating
250 Volts
Mounting Style
In-Line
Number Of Poles
1
Termination Style
Crimp, Crimp
Size (lxwxh)
10.32 mm x 41.275 mm
Lead Free Status / RoHS Status
Compliant
Lead Free Status / RoHS Status
Compliant
Non-Breakaway Holders
Catalog Symbol: HEB-AA
HEB-AD
HEB-AY, HEB-BA
HEB-CC
HEB-LL, HEB-NN, HEB-PP
HEB-SS, HEB-TT
In-Line Fuseholders
Single-Pole
Water-Resistant
Agency Information:
(1)
(2)
(3)
For breakaway holders See Page 2
HEB — For ⁄‹Ω £ ™∑ ≈ 1⁄Ω ™ ∑ (midget) fuse. Fuseholder rated 30A,
600V Typical fuse types: BAF, FNM, FNQ, and KTK (⁄Ω ¡ º-30A).
Ordering Information:
Also See Table on Page 3
Example:
A single-pole, in-line holder for ⁄‹Ω £ ™∑ ≈ 1⁄Ω ™ ∑ fuses. A single #12
solid copper wire is on the load side. A copper crimp is desired.
Two #6 solid copper wire is on the line side. A copper set-screw
is desired.
1. Choose HEB- Series.
2. Choose “A” for load side.
3. Choose “K” for line side.
Complete Catalog Number: HEB-AK.
For Insulating boots See Page 2 — Insulating boots are not
included with non-breakaway parts and must be ordered
separately. They come standard with the breakaway series.
When boots are utilized, extra heat retention requires that fuses
are sized at a minimum of 200% of the RMS load current.
Recommended Torque on Coupling Nut: 10-20 in-lb.
TRON
Single-Pole for ⁄‹Ω £ ™∑ ≈ 1⁄Ω ™ ∑ Fuses
7-16-03
UL Recognized, Guide IZLT2, File E14853
CSA Certified, Class 6225-01, File 47235
CE
HEB
(2)
(2)
, HEB-AE
, HEB-DD
N03082
®
(2)
(2)
In-Line Fuseholders
, HEB-BB
.HEB-ZA.
(2)
(2)
, HEB-AJ, HEB-AK, HEB-AL, HEB-AR,
, HEB-JJ, HEB-JK, HEB-JL, HEB-JY,
Load
Terminal
(2)
(1) (2) (3)
(2)
, HEB-QQ
, HEB-BC
, HEB-AB
(2)
(2)
, HEB-RR
, HEB-BD
(2)
, HEB-AC
Line
Terminal
(2)
(2)
,
,
(2)
,
Specification Data - Non-Breakaway & Load-Side Breakaway
Conductor Terminals
Terminal Type
Copper Crimp
Copper Set-Screw
Solid Copper Terminal for
Aluminum Wire Connector
Aluminum Crimp
Aluminum Set-Screw
Conductor Data
Size
#12 to #8
#12
#10
#6
#4
#8
#4
#6
#2
#4
#20 to #18
#12 to #3
#12 to #3
#8 to #12
#10 to #4
#8
#6
#6
#4
#3, #4
#2
#1, #2
#1/0
#12 to #2
#12 to #2
1
2
2
1
1
2
1
2
1
2
1
1
2
1
1
1
1
1
1
1
1
1
1
1
2
Bussmann
Form No. HEB Series
Series
Data Sheet: 2127
HEB
Page 1 of 3
Catalog
Symbol
Load &
Line
(2) & (3)
A
B
C
D
E
Z
J
K
S
N
P
Q
R
T
L
Y
®

Related parts for HEB-AC

HEB-AC Summary of contents

Page 1

... When boots are utilized, extra heat retention requires that fuses are sized at a minimum of 200% of the RMS load current. Recommended Torque on Coupling Nut: 10-20 in-lb. 7-16-03 N03082 Specification Data - Non-Breakaway & Load-Side Breakaway Conductor Terminals Terminal Type Copper Crimp (2) (2) , HEB-AC , (2) (2) , HEB-BD , (2) , HEB-RR , Copper Set-Screw Solid Copper Terminal for ...

Page 2

... HEB-AW-RLC-A). The insulating boots are not included with the Non-Breakaway Holders (ex. HEB-AA) or the individual pieces of the Breakaway parts (ex. HEB-AW, RLC-A). Two insu- lating boots must be ordered for each holder when ordering them separately. When insulated boots are utilized, extra heat retention requires that fuses are sized at a minimum of 200% of the RMS load current ...

Page 3

... Contact your local Bussmann representative for other possible terminations not listed. Bussmann Available P/N’s Non-Breakaway Breakaway P/N P/N Wire (Boots not included) (Boots included HEB-AA (1)(2) HEB-AW-RLCA (1)(2) ( HEB-AB (2) HEB-AW-RLC HEB-AC (2) HEB-AW-RLC-C ( HEB-AD (2) N HEB-AE (2) N HEB-AJ HEB-AW-RLC HEB-AK HEB-AW-RYC HEB-AL ...

Related keywords