B84142A20R EPCOS Inc, B84142A20R Datasheet - Page 3

Power Line Filters 20A 250V 2-LINE

B84142A20R

Manufacturer Part Number
B84142A20R
Description
Power Line Filters 20A 250V 2-LINE
Manufacturer
EPCOS Inc
Datasheets

Specifications of B84142A20R

Operating Frequency
50 to 60Hz
Current Rating (max)
20A
Voltage Rating Max
250VAC
Termination
Screw
Mounting Style
Flange
Product Length (mm)
121mm
Product Depth (mm)
105mm
Product Height (mm)
68mm
Voltage Rating
250 VAC / 250 VDC
Current Rating
20 A
Termination Style
Terminal Block
Lead Free Status / RoHS Status
Not Compliant
Typical circuit diagram
Technical data and measuring conditions
Rated voltage V
Rated current I
Test voltage V
Overload capability (thermal)
Leakage current I
Climatic category (IEC 60068-1)
Approvals
Characteristics and ordering codes
V
AC/DC
V
250
× = approval granted
Please read Cautions and warnings and
Important notes at the end of this document.
R
2-line filters
for converters and power electronics
LINE
L
N
I
A
10
20
30
40
50
60
60
R
test
R
R
leak
Terminal
cross section
mm
16
16
Screw stud
M6
4
4
6
6
2
I
mA
< 8
< 8
< 8
< 17
< 26
< 26
< 26
leak
250 V DC/AC, 50/60 Hz
Referred to 40 °C ambient temperature
1770 V DC, 2 s (line/line)
2700 V DC, 2 s (lines/case)
2.5 · I
At 250 V AC, 50 Hz
G075: 25/085/21 (–25 °C/+85 °C/21 days damp heat test)
EN 133200, UL 1283, CSA C22.2 No.8
1.5 · I
R000: 25/100/21 (–25 °C/+100 °C/21 days damp heat test)
R
mΩ
18
10
R
R
5
3.6
1.8
1.4
1.4
typ
for 3 min per hour or
for 30 s per hour
3
LOAD
SSB1515-U
Approx.
weight
kg
0.55
1.0
1.0
1.0
2.5
2.5
2.5
01/06
L’
N’
Ordering code
B84142A0010R000 ×
B84142A0020R000 ×
B84142A0030R000 ×
B84142A0040R000 ×
B84142A0050R000 ×
B84142A0060R000 ×
B84142A0060G075 —
B84142A*R000, G075
Approvals
×
×
×
×
×
×

Related parts for B84142A20R