2-87631-0 TE Connectivity, 2-87631-0 Datasheet

no-image

2-87631-0

Manufacturer Part Number
2-87631-0
Description
WIRE-BOARD CONN RECEPTACLE 24POS, 2.54MM
Manufacturer
TE Connectivity
Type
Housingr
Series
AMPMODU Mod IVr
Datasheet

Specifications of 2-87631-0

Wire Gauge
20-30
Number Of Contacts
24POS
Number Of Contact Rows
2
Body Orientation
Straight
Pitch (mm)
2.54mm
Gender
RCP
Housing Material
Nylon
Operating Temp Range
-65C to 105C
Current Rating (max)
3/ContactA
Voltage Rating Max
250VAC
Housing Color
Black
Product Depth (mm)
15.24mm
Product Length (mm)
30.48mm
Connector Type
Wire-to-Board
No. Of Contacts
24
No. Of Rows
2
Pitch Spacing
2.54mm
Mounting Type
Crimp
Rohs Compliant
Yes
Product Type
Connector
Termination Method To Wire/cable
Crimp
Mating Connector Lock
With
Strain Relief
Without
Connector Series
Mod IV
Keyed
No
Number Of Detents
2
Stamped
Yes
Flame Retardant
Yes
Housing Configuration
Both Ends Closed
Mating Connector Lock Type
Detent Latching
Contact - Rated Current (a)
3
Voltage Rating (vac)
250
Termination Resistance (m?)
12
Insulation Resistance (m?)
5,000
Dielectric Withstanding Voltage (v)
750
Centerline (mm [in])
2.54 [0.100]
Row-to-row Spacing (mm [in])
2.54 [0.100]
Number Of Positions
24
Number Of Rows
2
Contact Type
Socket
Connector Style
Receptacle
Mating Alignment
With
Mating Alignment Type
Latched
Ul Flammability Rating
UL 94V-0
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Approved Standards
UL E28476, CSA LR7189
Operating Temperature (°c)
-65 – +105
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
2-87631-0
Manufacturer:
TE Connectivity AMP Connectors
Quantity:
606
Dual Entry, End Stackable,
Low Profile, .100 x .100
[2.54 x 2.54] Centerline,
.200 [5.08] Tine Spacing
Material and Finish
Housing — Glass-filled thermoplastic,
black, 94V-0 rated
Plating A — Duplex .000030 [0.00076]
gold on contact area, .000150-0.000300
[0.00381-0.00762] matte tin on solder
area all over .000050 [0.00127] nickel
Plating B — Duplex .000010
[0.000254] gold on contact area,
.000150-.000300 [0.00381-0.00762]
matte tin on solder area all over .000050
[0.00127] nickel
Plating C — .000150-.000300
[0.00381-0.00762] matte tin on solder
leads, all over .000050 [0.00127] nickel
Note: All part numbers are RoHS
Catalog 1307819
Revised 8-08
www.tycoelectronics.com
compliant.
are metric equivalents.
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
AMPMODU Interconnection System
Mod IV Receptacle Assemblies, Single-Row, Outrigger Design
.100 x .100 [2.54 x 2.54] Centerline, End To End Stackable
Notes: 1. Tyco Electronics recommends mating gold or duplex plated headers with duplex plated receptacle
(Standoffs)
No. of
Pos.
[3.56]
[0.51]
.140
.020
10
11
12
13
14
15
16
17
18
19
20
30
40
3
4
5
6
7
8
9
2. To obtain the minimum mating post length, add .020 [0.51] (not including the post lead in chamfer) to
assemblies.
the maximum point-of-contact dimension and add .062 [1.57] for recommended board thickness if used in
bottom entry application.
1.000 [25.40]
1.100 [27.94]
1.200 [30.48]
1.300 [33.02]
1.400 [35.56]
1.500 [38.10]
1.600 [40.64]
1.700 [43.18]
1.800 [45.72]
1.900 [48.26]
2.000 [50.80]
3.000 [76.20]
4.000 [101.60]
.300 [7.62]
.400 [10.16]
.500 [12.70]
.600 [15.24]
.700 [17.78]
.800 [20.32]
.900 [22.86]
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
A
[2.54]
.100
Typ.
[3.56]
.140
Dimensions
A
Recommended PC Board Hole Layout
1.000 [25.40]
1.100 [27.94]
1.200 [30.48]
1.300 [33.02]
1.400 [35.56]
1.500 [38.10]
1.600 [40.64]
1.700 [43.18]
1.800 [45.72]
1.900 [48.26]
2.900 [73.66]
3.900 [99.06]
.200 [5.08]
.300 [7.62]
.400 [10.16]
.500 [12.70]
.600 [15.24]
.700 [17.78]
.800 [20.32]
.900 [22.86]
B
.075 +.005
[
1.90
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-1106-0803
[0.89±0.08]
.035±.003
-.000
+0.13
-.000
]
[1.34]
.053
Typ.
B
5-147720-2
5-147720-3
5-147720-4
5-147720-5
5-147720-6
5-147720-7
5-147720-8
5-147720-9
6-147720-0
6-147720-1
6-147720-2
6-147720-3
6-147720-4
6-147720-5
6-147720-6
6-147720-7
6-147720-8
7-147720-8
8-147720-8
8-147720-9
Plating A
Dia.
[6.22]
.245
(Localized Gold
Plate Area)
[3.17±0.25]
.125±.010
Contact Plating/Part Nos.
[2.72]
.107
Typ.
[2.54]
[3.77]
.100
Typ.
.148
Typ.
5-147726-2
5-147726-3
5-147726-4
5-147726-5
5-147726-6
5-147726-7
5-147726-8
5-147726-9
6-147726-0
6-147726-1
6-147726-2
6-147726-3
6-147726-4
6-147726-5
6-147726-6
6-147726-7
6-147726-8
7-147726-8
8-147726-8
8-147726-9
Plating B
South America: 55-11-2103-6000
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-8706-080-208
[5.08]
.200
Point of
Contact
5-147727-2
5-147727-3
5-147727-4
5-147727-5
5-147727-6
5-147727-7
5-147727-8
5-147727-9
6-147727-0
6-147727-1
6-147727-2
6-147727-3
6-147727-4
6-147727-5
6-147727-6
6-147727-7
6-147727-8
7-147727-8
8-147727-8
8-147727-9
Plating C
[5.08±0.08]
.200±.003
Typ.
181
5

Related parts for 2-87631-0

2-87631-0 Summary of contents

Page 1

... Notes: 1. Tyco Electronics recommends mating gold or duplex plated headers with duplex plated receptacle assemblies obtain the minimum mating post length, add .020 [0.51] (not including the post lead in chamfer) to the maximum point-of-contact dimension and add .062 [1.57] for recommended board thickness if used in Note: All part numbers are RoHS bottom entry application ...

Page 2

... Notes: 1. Tyco Electronics recommends mating gold or duplex plated headers with duplex plated receptacle assemblies obtain the minimum mating post length, add .020 [0.51] (not including the post lead in chamfer) to the maximum point-of-contact dimension and .062 for recommended board thickness if used in bottom entry application ...

Page 3

... Notes: 1. Tyco Electronics recommends mating gold or duplex plated headers with duplex plated receptacle assemblies obtain the minimum mating post length, add .020 [0.51] (not including the post lead in chamfer) to Note: All part numbers are RoHS the maximum point-of-contact dimension, and .062 [1.57] for recommended board thickness if used in bot- compliant ...

Page 4

... Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Mod. IV Receptacle Assemblies, Double-Row, .100 x .100 [2.54 x 2.54] Centerline Dimensions No. of Pos 2.100 [53.34] 2.000 [50.80] 44 2.200 [55.88] 2.100 [53.34 ...

Page 5

... These receptacles are available in single-row and double-row configurations with a contact centerline spacing of .100 x .100 [2.54 x 2.54]. Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. ...

Page 6

... Insulation Resistance: 5000 megohms (min.) Mating Force (Receptacle Assemblies): 9.0 oz. [2.50N] (max.) per contact Unmating Force (Receptacle Assemblies): 1.5 oz. [0.42N] (min.) per contact Durability: Tested to 200 cycles (min.) for .000030 [0.00076] gold plated contacts Dimensions are shown for reference purposes only. ...

Page 7

... Notes: 1. Tyco Electronics recommends mating gold or duplex plated headers with duplex plated receptacle assemblies obtain the minimum mating post length, add .020 [0.51] (not including the post lead in chamfer) to the maximum point-of-contact dimension, and .062 [1.57] for recommended board thickness if used in bottom entry application 3 ...

Page 8

... Notes: 1. Tyco Electronics recommends mating gold or duplex plated headers with duplex plated receptacle assemblies obtain the minimum mating post length, add .020 [0.51] (not including the post lead in chamfer) to the maximum point-of-contact dimension, and .062 [1.57] for recommended board thickness if used in bottom entry application. ...

Page 9

... Related Product Data Typ. Mateable Headers — Refer to Mating Post Selection Guide — page 90 Performance Specifications — .040±.003 page 186 [1.02±0.08] Technical Documents — page 276 ...

Page 10

... Notes center holddown obtain the minimum mating post length, add .020 [0.51] (not including the post lead in chamfer) to the maximum point-of-contact dimension and .062 [1.57] for recommended board thickness in bottom entry applications. 5 190 ...

Page 11

... Plating C — .000150-.000300 [0.00381-0.00762] tin-lead over .000050 [0.00127] nickel [0.10] Related Product Data Mateable Headers — Refer to Mating Post Selection Guide — page 90 Performance Specifications — page 186 Technical Documents — page 276 Product Specification 108-25022 ...

Page 12

... Notes obtain the minimum mating post length, add .020 [0.51] (not including the post lead in chamfer) to the maximum point-of-contact dimension and .062 [1.57] for recommended board thickness in bottom entry applications. 5 192 Catalog 1307819 ...

Page 13

... Shrouded headers provide full pin protection ■ Polarized headers ■ Vertical headers available with ACTION PIN posts or .025 [0.64] square solder posts ■ Repairable ACTION PIN posts ■ Simple seating tooling for headers with ACTION PIN posts Recognized under the ■ ...

Page 14

... Headers and Receptacles — Current Rating — –65°C to +125°C (black thermoplastic 3 amperes max. for single contact; housings, 94V-0 rated) 2 amperes max. per contact for fully Durability (Tested to) — 200 cycles energized connector for .000030 [0.00076] gold plating; Voltage Rating — 250 VAC 75 cycles for .000015 [0.00038] gold Dielectric Rating — ...

Page 15

... Notes: 1. .115 [2.92] tail length is for use with .062 [1.57] PC boards; .145 [3.68] tail length is for use with .093 [2.36] PC boards. Notes: 2. Receptacle assemblies with low force contacts are available, consult Tyco Electronics. 3. .256 [6.50] minimum positive pin stop to prevent shorting between rows. ...

Page 16

... Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Receptacle Assemblies, Board Mount, Double-Row, Closed Entry, .100 x .100 [2.54 x 2.54] Centerline .115 [2.92] .410 [10.41] B ±.008 [±0.20] .100 Typ. ...

Page 17

... AMPMODU Interconnection System Receptacle Assemblies, Board Mount, Triple-Row, Closed Entry, .100 x .100 [2.54 x 2.54] Centerline Horizontal Mount (with Guide Pin Slots and Standoffs) .179 Typ. [4.55] Material and Finish .338 Housing — Glass-filled thermoplastic, [8.59] black, 94V-0 rated .144 Contacts — Phosphor bronze, plated [3 ...

Page 18

... Tyco Electronics. 198 Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Headers, Straight Post, Double-Row, .100 x .100 [2.54 x 2.54] Centerline Pos. Ref .100 [2.54] .085 .200 [2.16] [5.08] B ...

Page 19

... Headers with ACTION PIN posts are for use with .093 [2.36] nominal or thicker PC boards. 2. Application tooling for installing headers with ACTION PIN posts is shown on pages 152 and 153. 3. Headers with .250 [6.35] tail length can be made available with make first/break last contacts, consult Tyco Electronics ...

Page 20

... Tyco Electronics. 200 Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Headers, Right-Angle Post, Double-Row, .100 x .100 [2.54 x 2.54] Centerline .762 Max. [19.35] .599 [15.21] .040 A [1.02] Typ. ...

Page 21

... AMPMODU Interconnection System Headers, Straight Post, Triple-Row, .100 x .100 [2.54 x 2.54] Centerline Solder Posts (with Pin Protection and Guide Pins) .100 [2.54] .100 [2.54] .085 [2.16] .040 [1.02] (4 Sides) Material and Finish Housing — Glass-filled thermoplastic, black, 94V-0 rated .210 [5.33] Posts — ...

Page 22

... Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Headers, VRM (Voltage Regulator Module), .100 x .100 [2.54 x 2.54] Centerline A B .110 [2.79] .440 [11.18] B .100 [2.54] .125 [3 ...

Page 23

... Shroud Board Mounted PC Board Straight Posts Typical Assembly Technical Documents — page 276 Double-Row, .100 x .100 [2.54 x 2.54] Centers Part No. 102114-1 Material — Black glass-filled polyester Note: All part numbers are RoHS compliant. Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified ...

Page 24

... For Shrouded Double-Row, 3 and 4 Sided Headers, .100 x .100 [2.54 x 2.54] Centers See Fig. 2 See Fig. 4 Note: Right-angle (Figs. 2 and 3) and “T” (Fig. 1) configurations of barrier insert establish polarization; bar (Fig. 4) configuration of barrier insert compartmentalizes header. Note: All part numbers are RoHS compliant. Dimensions are shown for reference purposes only ...

Page 25

... Material Black thermoplastic, flame retardant Part Numbers 499991-2 (Packaged 50 per bag) 499991-3 (Packaged 1000 per bag) Related Product Data Low Profile Headers used with — pages 135-140 Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www ...

Page 26

... Extraction housing Tool Slot Contact Clearance Hole *If post is longer than maximum specified, post tip may butt against wire ends. Dimension defines .025 x .025 [0.64 x 0.64] portion of post. Dimensions are shown for reference purposes only. Specifications subject to change. Left End Open (for ...

Page 27

... AMP-O-LECTRIC Model “G” machines (shown on page 270), as well as other bench machines and fully automatic AMPOMATOR lead making machines. Notes: 1. These contacts must be crimped in accordance with Tyco Electronics Specification No. 114-25006 in order to function properly in a connector housing. 2. Extraction Tool No. 91084-1 is used for removing individual contacts from connector housings and for detaching contacts from mating posts. ...

Page 28

... AMPMODU Interconnection System Wire-Applied Housings for Locking Clip Contacts, Single-Row, .100 [2.54] Centerline A C Typ. .085 [2.16] .100 Typ. [2.54] B Note: Housing illustrated above is the “Both Ends Closed” version. No. of Dimensions Pos .108 [2.74] — 2 .216 [5.49] .100 [2.54] 3 ...

Page 29

... Length) .025 [0.64] Sq. Post A (Shown for Ref. only) .100 Typ. [2.54] .100 [2.54] .058 B [1.47] Note: Housing illustrated above is the “Both Ends Closed” version. Both Ends Closed Key Keyway Right End Open No. of Dimensions Pos .116 [2.95] — 4 .216 [5.49] ...

Page 30

... Specifications subject to change. Wire-to-Board 1-87456-5 D-R Housing , Plain 6-87756-6 Std. Pressure Contacts 87483-3 D-R Housing with Mounting Ears 6-87756-6 Std. Pressure Contacts 102241-8 S-R Housing Polarized with Detent 102128-1 High Pressure Contacts 103168-8 Hdr 1-87756-6 Std. Pressure Plain 6-87456-6 D-R Housing, Contacts ...

Page 31

... AMP-O-LECTRIC Model “K” machines. Call the Technical Support Center (1-800-522-6752) for part nos. [0.00038] gold on contact area, with gold of applicators for use with the AMP-O-LECTRIC Model “G” machines (shown on page 270), as well as other bench flash over .000050 [0.00127] nickel on machines and fully automatic AMPOMATOR lead making machines ...

Page 32

... Plating D — Selectively plated .000050 [0.00127] gold on contact area, with gold flash over .000050 [0.00127] nickel on entire contact Plating E — Selectively plated .000030 [0.00076] gold on contact area, with gold flash over ...

Page 33

... Ph Bz **For use with AMP-O-LECTRIC Model “K” machines. Call the Technical Support Center (1-800-522-6752) for part nos. of applicators for use with the AMP-O-LECTRIC Model “G” machines (shown on page 270), as well as other bench machines and fully automatic AMPOMATOR lead making machines. ...

Page 34

... Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Mod IV Wire-Applied Housings, Single-Row, .100 [2.54] Centerline A Max. .050 ±.003 [1.27 [±0.08] Typ. .070 ...

Page 35

... AMPMODU Interconnection System Mod IV Wire-Applied Housings, Single-Row, .100 [2.54] Centerline Polarized (with Detent Latching) .175 [4.45] Material Black thermoplastic, flame retardant .071 Related Product Data [1.80] Contacts — pages 211-213 Mateable Headers and Posts — pages 115, 116 .056 Flexible Film Connectors, [1.42] Single-Row Pin Assemblies — ...

Page 36

... Notes: 1. Strain reliefs are available and may be purchased separately. Consult Tyco Electronics. Notes: 2. Contact Extraction/Lance Reset Tool No. 843996-3. Note: All part numbers are RoHS compliant. Dimensions are shown for reference purposes only. ...

Page 37

... AMPMODU Interconnection System Mod IV Wire-Applied Housings, Double-Row, .100 x .100 [2.54 x 2.54] Centerline Polarized .175 [4.45] Material Black thermoplastic, flame retardant Related Product Data Contacts — pages 211-213 Mateable Headers and Posts— pages 117-131 Technical Documents — pages 277, 278 Product Specification 108-25007, 108-25019, 108-25020, No ...

Page 38

... Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Mod IV Wire-Applied Housings, Double-Row, .100 x .100 [2.54 x 2.54] Centerline .175 [4.45] A ±.003 ±.003 B C [±0.08] [±0.08] .100 Typ ...

Page 39

... C. America: 52-55-1106-0803 Part Nos. Without Strain Relief With Strain Relief Stamped* Unstamped** Stamped* 1-87631-4 1-87631-3 87922-5 1-87631-6 1-87631-5 87733-1 1-87631-8 1-87631-7 — 2-87631-0 1-87631-9 87733-3 2-87631-2 2-87631-1 87733-4 2-87631-4 2-87631-3 — 2-87631-6 2-87631-5 87733-6 2-87631-8 2-87631-7 87733-7 3-87631-0 2-87631-9 87733-8 ...

Page 40

... Tyco Electronics stamped on housing. †Non-functional slot is used for gating purposes during injection molding process. This gating feature is not inherent in all production molds. Therefore, the depicted slot will only be present on housings produced on mold tooling requiring this gating feature. ...

Page 41

... Dimensions are shown for USA: 1-800-522-6752 reference purposes only. Canada: 1-905-470-4425 Specifications subject Mexico: 01-800-733-8926 to change. C. America: 52-55-1106-0803 Wire-to-Board 104482-9 Short Point Recept. Housing 104257-5 MTE Recept. Housing 1-104480-5 Short Point Contact 221 South America: 55-11-2103-6000 Hong Kong: 852-2735-1628 Japan: 81-44-844-8013 UK: 44-8706-080-208 5 ...

Page 42

... Model “K” machines. Call the Tooling/Technical Assistance Center (1-800-722-1111) for part nos. of applicators for use with the Model “G” machines (shown on page 288), as well as other bench machines and fully automatic AMPOMATOR lead making machines. ...

Page 43

... AMPMODU Interconnection System Short Point Wire-Applied Housings, Double-Row, Non-Polarized, .100 x .100 [2.54 x 2.54] Centerline Material Black thermoplastic, flame retardant, 94V-0 rated Related Product Data .049 [1.24] Performance Characteristics — page 221 Contacts — page 222 Mateable Headers — .100 pages 104, 105 [2 ...

Page 44

... Material Black thermoplastic, flame retardant, 94V-0 rated Related Product Data Performance Characteristics — page 221 Contacts — page 222 Mateable Headers — pages 104, 105, 135-138 Technical Documents — pages 276-278 Product Specification 108-1472 Application Specification 114-25038 5 224 Catalog 1307819 Dimensions are in inches and ...

Page 45

... Contact Termination Resistance — 15 milliohms (max.) Dielectric Withstanding Voltage — At Sea Level–600 VAC, rms At 70,000 Ft. [21 336 m]–225 VAC, rms Insulation Resistance — 5,000 megohms (min.) Environmental Characteristics Operating Temperature — -65°C to +105°C Vibration — ...

Page 46

... Mating AMPMODU Double-Row Shrouded Header Assemblies must have .318 [8.08] mating post length and .150 [3.81] dimension from centerline of last 1 post to inside of end shroud wall. Surface Mount Right-Angle and Vertical Headers are also available (see pages 251 and 252) 2 226 Catalog 1307819 ...

Page 47

... AMPMODU Interconnection System MTE Interconnection System Wire-to-Wire Pin Assemblies, Shrouded Polarized/Latching (See pages 236 & 237) Receptacle Assemblies, Polarized/Latching (See pages 230 & 231) Receptacle Contact, Insulation Displacement (Used in all Receptacle Assemblies) Crimp Snap-In Receptacle Contact (Used with Unloaded Housings— ...

Page 48

... Mating post length for preloaded housings is .200 [5.08] min., .250 [6.35] max. Related Product Data Mateable AMPMODU Products Breakaway Headers — pages 102- 110 (with .230 mating length) Reeled Breakaway Headers — ...

Page 49

... Notes: 1. Receptacle assemblies are furnished with strip contacts partially inserted into housing—contacts latched into “preload” windows. Contacts are fully inserted into housings automatically when terminated with Tyco Electronics application machines, or manually when terminated with Tyco Electronics pistol grip hand tool. ...

Page 50

... Plating B — Duplex plated .000015 [0.00038] gold on contact area, .000050 [0.00127] min. tin in crimp area, with entire contact underplated .000050 [0.00127] nickel Plating C — .000100 [0.00254] tin over .000050 [0.00127] nickel on entire ...

Page 51

... Notes: 1. Receptacle assemblies are furnished with strip contacts partially inserted into housing—contacts latched into “preload” windows. Contacts are fully inserted into housings automatically when terminated with Tyco Electronics application machines, or manually when terminated with Tyco Electronics pistol grip hand tool. ...

Page 52

... Preassembled housings in strip form are available in positions 2 thru 12. For ease of handling, positions 2 thru 5 are recommended when using the Tyco Electronics Manual Pistol Grip Tool. Material and Finish Housing — Black thermoplastic, 94V-0 rated Contacts — Phosphor Bronze, plated as follows: Plating A — Duplex plated .000030 [0 ...

Page 53

... Notes: 1. Receptacle assemblies are furnished with strip contacts partially inserted into housing—contacts latched into “preload” windows. Contacts are fully inserted into housings automatically when terminated with Tyco Electronics application machines, or manually when terminated with Tyco Electronics pistol grip hand tool ...

Page 54

... Contacts are fully inserted into housings automatically when terminated with Tyco Electronics application machines, or manually when terminated with Tyco Electronics pistol grip hand tool. 2. High pressure receptacle contacts can be made available in other housing styles and position sizes. Contact your Tyco Electronics sales representative. Note: All part numbers are RoHS compliant. ...

Page 55

... AMPMODU Interconnection System MTE High Pressure Receptacle Assemblies – Guide Ribs Preassembled housings in strip form are available in positions 2 thru 12. For ease of handling, positions 2 thru 5 are recom- mended when using the Tyco Electronics Manual Pistol Grip Tool. Material and Finish Housing — Thermoplastic, black, 94V-0 rated Contacts — ...

Page 56

... Preassembled housings in strip form are available in positions 2 thru 12. For ease of handling, positions 2 thru 5 are recom- mended when using the Tyco Electronics Manual Pistol Grip Tool. Material and Finish Housing — Black thermoplastic, 94V-0 rated Contacts — Phosphor Bronze, plated as follows: Plating A — Duplex plated .000030 [0 ...

Page 57

... Notes: 1. Pin assemblies are furnished with strip contacts partially inserted into housing—contacts latched into “preload” windows. Contacts are fully inserted into housings automatically when terminated with Tyco Electronics application machines, or manually when terminated with Tyco Electronics pistol grip hand tool ...

Page 58

... Preassembled housings in strip form are available in positions 2 thru 12. For ease of handling, positions 2 thru 5 are recom- mended when using the Tyco Electronics Manual Pistol Grip Tool. Material and Finish Housing — Black thermoplastic, 94V-0 rated Contacts — Phosphor Bronze, plated as follows: Plating A — Duplex plated .000030 [0 ...

Page 59

... Notes: 1. Pin assemblies are furnished with strip contacts partially inserted into housing—contacts latched into “preload” windows. Contacts are fully inserted into housings automatically when terminated with Tyco Electronics application machines, or manually when terminated with Tyco Electronics pistol grip hand tool ...

Page 60

... Pin Assemblies with Guide Ribs, Installed in Panel Mount Pin Shroud (Refer to pages 238, 239 & 242) Single-Row Coupling Shroud Headers, Polarized/Latching, Straight and Right Angle Post, with or without Holddown (See pages 244-252) USA: 1-800-522-6752 South America: 55-11-2103-6000 ...

Page 61

... Application Specification 114-25026 Receptacle Assemblies with Guide Ribs (Refer to pages 232, 233 & 235) 1 Mating AMPMODU Double-Row Shrouded Headers must have .318 [8.08] mating post length and .150 [3.81] dimension from centerline 1 of last post to inside of end shroud wall. Typical Application of Double-Row Coupling Shroud and Mating AMPMODU Products Note: All part numbers are RoHS compliant ...

Page 62

... USA: 1-800-522-6752 South America: 55-11-2103-6000 Canada: 1-905-470-4425 Hong Kong: 852-2735-1628 Mexico: 01-800-733-8926 Japan: 81-44-844-8013 C. America: 52-55-1106-0803 UK: 44-8706-080-208 .250 [6.35] Panel Mount Pin Shroud ...

Page 63

... Application Specification 114-25026 Receptacle Assemblies with Guide Ribs, Installed in Single-Row Coupling Shroud (Refer to pages 232, 233, 235 & 240) Typical Application of Panel Mount Pin Shroud and Mating AMPMODU Products Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified ...

Page 64

... Housing — Black thermoplastic, 94V-0 rated Posts — Brass, plated as follows: Plating A — Duplex plated .000030 [0.00076] gold on contact area, .000100 [0.00254] min. tin on solder area, with entire post underplated .000050 [0.00127] nickel Plating B — Duplex plated .000015 [0.00038] gold on contact area, .000100 [0 ...

Page 65

... Notes: 1. Selectively loaded headers are available, consult Tyco Electronics. 2. Use Keying Tool No. 91417-1 to remove post for keying. Note: All part numbers are RoHS compliant. Catalog 1307819 Dimensions are in inches and ...

Page 66

... X .060 [1.52] .340±.003 .100* Typ. [8.64±0.08] [2.54] Recommended PC Board Hole Layout (PC board thickness (for Holddown Feature) is .062±.008 [1.57±0.20]) *±.003 [±0.08]; tolerance not to accumulate within one connector pattern. Without Holddown A B .060 [1.52] C .100 Typ. ...

Page 67

... Notes: 1. Selectively loaded headers are available, consult Tyco Electronics. 2. Use Keying Tool No. 91417-1 to remove post for keying. Note: All part numbers are RoHS compliant. Catalog 1307819 Dimensions are in inches and ...

Page 68

... Application Specification 114-25026 248 Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System MTE Headers, Shrouded Latching, Single-Row .100 [2.54] Centerline .535 [13.59] Position No. 1 Indicator A .060 [1.52 Plc.) C .120 X [3 ...

Page 69

... Material and Finish .060 Housing — Black thermoplastic, [1.52] 94V-0 rated Posts — Brass, duplex plated .000015 [0.00038] gold on contact area, .000100 [0.00254] min tin on solder tail, with entire post underplated .000050 .120 [0.00127] nickel [3.05] .060 [1.52] Related Product Data Mateable AMPMODU MTE Products — ...

Page 70

... Holddown) Material and Finish Housing — Black thermoplastic, 94V-0 rated Posts — Brass, duplex plated .000015 [0.00038] gold on contact area, .000100 [0.00254] min. tin on solder tail, with entire post underplated .000050 [0.00127] nickel Related Product Data Mateable AMPMODU MTE Products — ...

Page 71

... Housing — Black thermoplastic, 94V-0 rated Posts — Brass, plated as follows: Plating A — Duplex plated .000030 [.00076] gold on contact area, .000100 [.00254] min. tin on solder area, with entire post underplated .000050 [.00127] nickel. K Plating B — Duplex plated .000015 [.00038] gold on contact area, .000100 [ ...

Page 72

... Housing — Black thermoplastic, 94V-0 rated Posts — Brass, plated as follows: Plating A — Duplex plated .000030 [.00076] gold on contact area, .000100 [.00254] min. tin on solder area, with entire post underplated .000050 [.00127] nickel. Plating B — Duplex plated .000015 [.00038] gold on contact area, .000100 [ ...

Page 73

... Plating C *For use with Model “K” machines. Call the Technical Support Center (1-800-522-6752) for part nos. of applicators for use with the Model “G” machines (shown on page 270), as well as other bench machines and fully automatic AMPOMATOR lead making machines. ...

Page 74

... AMP-O-LECTRIC Model “K” machines. Call Technical Support Center (1-800-522-6752) for part nos. of applicators for use with the AMP-O-LECTRIC Model “G” machines (shown on page 270), as well as other bench machines and fully automatic AMPOMATOR lead making machines. ...

Page 75

... High pressure - 26 oz. [7.23 N] Standard pressure - 9 oz. [2.50 N] Min. Unmating Force — High pressure — 5 oz. [1.39 N] Standard pressure — 1.5 oz. [0.417 N] Contact Retention in Housing — 5 lb. [22.24 N] per contact min. South America: 55-11-2103-6000 Hong Kong: 852-2735-1628 Japan: 81-44-844-8013 UK: 44-8706-080-208a 5 255 ...

Page 76

... Note: Contact Extraction/Lance Reset Tool No. 843477-3, see page 265. Part No. 87077-2 (Plugs directly into housing) Note: All part numbers are RoHS compliant. Dimensions are shown for reference purposes only. Specifications subject to change ...

Page 77

... Application Specification 18 114-25032 20 Instruction Sheet *Cavity identification — first cavity (one side); Tyco Electronics Part No. and date code stamped on housing where size permits. 408-6532 Note: Contact Extraction/Lance Reset Tool No. 843477-3, see page 265. Keying Plugs Part No. 86286-1 (Plugs into receptacle contact) Part No. 87077-2 Material — ...

Page 78

... AMPMODU Interconnection System Low Profile Covers for Double-Row MT Receptacle Assemblies Front Covers A - Polarizing Cover (Mates with AMPMODU 4-sided shrouded headers. Refer to pages 117, 122, 126, 130.) .750 [19.05 Ejection Cover (Mates with AMP-LATCH universal ejection style pin headers equipped with latching ears, Part No ...

Page 79

... Values in brackets www.tycoelectronics.com are metric equivalents Ejection Cover (Mates with AMP-LATCH universal ejection style pin headers equipped with latching ears, Part No. 102185-2 (with push tabs) or Part No. 102312-2 (without push tabs), see Tyco Electronics Catalog 82012. 1.120 Assembled* [28.45] Top View ...

Page 80

... Shields for right-angle headers have integral cantilever beams which provide good contact with the mating shielded MT receptacle assembly, without the use of a separate RF gasket. USA: 1-800-522-6752 South America: 55-11-2103-6000 Canada: 1-905-470-4425 Hong Kong: 852-2735-1628 Mexico: 01-800-733-8926 Japan: 81-44-844-8013 C. America: 52-55-1106-0803 UK: 44-8706-080-208 ...

Page 81

... AMPMODU Interconnection System Shielding Hardware and Accessories for Double-Row MT Receptacle Assemblies Two-Piece Shields— Straight Exit Material and Finish Shell Halves — Copper alloy, .020 [0.51] thick; pretinned .000030 [0.00076] min. Related Product Data Double-Row MT Receptacle Assemblies — pages 256, 257 Non-Polarizing Covers (Part No ...

Page 82

... Notes: 1. Match shield size to number of connector positions. 2. Hole is provided in 26 through 60-position cable shields for application of optional cable tie pull ring after assembly. Note: All part numbers are RoHS compliant. Dimensions are shown for reference purposes only. ...

Page 83

... Model “K” machines. Call the Tyco Electronics Technical Support Center (1-800-522-6752) for part nos. of applicators for use with the AMP-O-LECTRIC Model “G” machines (also shown on page 270), as well as other bench machines and fully automatic AMPOMATOR lead making machines. ...

Page 84

... D ±.003 [±0.08] [2.54±0.08] ±.003 2D [±0.08] Recommended PC Board Hole Layout for 6, 8 and 10 Positions D - Contact centerline is .100 [2.54]; ±.003 [0.08] tolerances not to accumulate within one connector pattern. Dimensions No. of Pos .200 [5.08] .430 [10.92] 8 ...

Page 85

... AWG Application Tooling — 30-26 pages 273-275 26-22 22-20 Technical Documents — Note: Termination tooling for MT receptacle insulation displacement contacts is shown on pages 273-275. pages 277, 278 Product Specification 108-25015, 108-25018, 108-25030 Application Specification 114-25032 Instruction Sheet 408-6532 MT receptacle contacts incorporate the following features ...

Page 86

... Dimensions are shown for reference purposes only. Specifications subject to change. Specifications Contact Current Rating — 3 amperes Termination Resistance — 12 milliohms (max.) — gold plated contacts 18 milliohms (max.) — tin plated contacts Durability — Ref. Product Specification 108-25031 USA: 1-800-522-6752 South America: 55-11-2103-6000 ...

Page 87

... Pos Note: Mini-Tandem Spring contacts for use in these housings are shown on page 269. Material—Natural color nylon, 94V-2 rated Keying Plug Part No. 531226-1 (Plugs directly into housing) Note: All part numbers are RoHS compliant. Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified ...

Page 88

... A 6 .300 [7.62] 8 .400 [10.16] 12 .600 [15.24] 16 .800 [20.32] Note: Mini-Tandem Spring contacts for use in these housings are shown on page 269. Note: All part numbers are RoHS compliant. Dimensions are shown for reference purposes only. Specifications subject to change. .030 [0.76] .036 [0 ...

Page 89

... AMP-O-LECTRIC Model “K” machines. Call the Tooling/Technical Assistance Center (1-800-522-6752) for part nos. of applicators for use with the AMP-O-LECTRIC Model “G” machines (shown on page 270), as well as other bench machines and fully automatic AMPOMATOR lead making machines. ...

Page 90

... Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Application Tooling for Wire Crimp Contacts AMP-O-LECTRIC Model “G” Terminating Machine (Shown with Optional Crimp Force Monitor) A totally new design of our most popular machine for bench-top operation. It features a quiet and reliable ...

Page 91

... Values in brackets www.tycoelectronics.com are metric equivalents. (Continued) AMP 5K/40 Terminator Dimensions are shown for USA: 1-800-522-6752 reference purposes only. Canada: 1-905-470-4425 Specifications subject Mexico: 01-800-733-8926 to change. C. America: 52-55-1106-0803 5 271 South America: 55-11-2103-6000 Hong Kong: 852-2735-1628 Japan: 81-44-844-8013 UK: 44-8706-080-208 ...

Page 92

... In fact, that’s how you standardize your process. But for ongoing quality control, testing every crimp, SLE is the choice. It’s known worldwide, and meets our standards for a high performance terminating system. That’s how you can be sure. ...

Page 93

... The heads are easily interchanged to run different products. *The IDC Electric Power Unit’s cycle rate is approximately 7,200 cycles per hour, with exact produc- tion rates depending upon operator dexterity. Modular Heads: ...

Page 94

... The feed track is a constant force, *At a rate of 13-25 positions at a time. 2700 lb. Power Unit With Cable Notching Die Equipped with a cable notching die an adapter kit, this fully pneumatic bench ...

Page 95

... AMPMODU Interconnection System Application Tooling for Insulation Displacement Crimp (IDC) Contacts and Connectors Tooling shown on this page CHAMPOMATOR Model 2.5 Terminating Machine No. 354786-(*) is designed to terminate IDC contacts for various AMPMODU wire-to-board connectors. Refer to page 88 to determine the applica- ble connectors. This compact bench ...

Page 96

... Receptacle Assemblies, Horizontal and Vertical Board Mount — Pages 168-192: 114-25018 AMPMODU Mod. II and IV Receptacle Assembly, PC Board Mounted, Vertical, Application of .025 [0.64] Square Posts, Headers, Accessories and Tooling — Pages 92-105, 114-140, 145-153, 163-167: 114-25028 ACTION PIN Contacts with Tyco Electronics Headers, Application 114-13011 AMPMODU ...

Page 97

... Short-Point Wire-Applied Contacts and Housings — Pages 221-224: 108-1472 AMPMODU MTE Interconnection System — Pages 225-252: 108-25034 AMPMODU MT and Shielded MT Interconnection System — Pages 255-265: 108-25015 108-25018 108-25030 AMPMODU Level V, IDC Connectors — 108-25028 Mini-Tandem Spring Receptacle Contacts — Pages 266-269: ...

Page 98

... AMPMODU MT Connectors AMPMODU Level V, IDC Connectors — 408-6843 Tyco Electronics Extraction Tool 91409-1 Standard Tandem Spring and Mini-Tandem Spring Receptacle Contacts — Pages 266-269: 408-7909 Tyco Electronics Hand Crimping Tool 91540-1 Note: All part numbers are RoHS compliant. Dimensions are shown for reference purposes only ...

Related keywords