1-87483-5 TE Connectivity, 1-87483-5 Datasheet

no-image

1-87483-5

Manufacturer Part Number
1-87483-5
Description
06 MODIV HSG COMP DR .100 EARS
Manufacturer
TE Connectivity
Type
Housingr
Series
Mod IV Seriesr
Datasheet

Specifications of 1-87483-5

Wire Gauge
20-32
Number Of Contacts
6POS
Number Of Contact Rows
2
Body Orientation
Straight
Pitch (mm)
2.54mm
Gender
RCP
Housing Material
Nylon
Current Rating (max)
3/ContactA
Housing Color
Black
Rohs Compliant
YES
Product Type
Receptacles / Sockets - Housings
Contact Gender
Socket (Female)
Pitch
2.54 mm
Number Of Positions / Contacts
6
Number Of Rows
2
Row Spacing
2.54 mm
Latching Type
Mounting Holes
Termination Style
Crimp
Connector Type
Housing
Termination Method To Wire/cable
Crimp
Mating Connector Lock
With
Strain Relief
Without
Connector Series
Mod IV
Keyed
No
Stamped
No
Housing Configuration
Both Ends Closed
Mating Connector Lock Type
Mounting Holes
Centerline (mm [in])
2.54 [0.100]
Row-to-row Spacing (mm [in])
2.54 [0.100]
Number Of Positions
6
Contact Type
Socket
Connector Style
Receptacle
Mating Alignment
Without
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
1-87483-5
Manufacturer:
TE Connectivity AMP Connectors
Quantity:
215
Product Facts
Performance
Characteristics
Contact Current Rating—3 amperes
Termination Resistance:
12 milliohms (max.)—Gold plated
contacts
16 milliohms (max.)—Tin plated
contacts
Durability— Ref. AMP Product
Specification 108-36028 and
108-36028-1
Catalog 1307819
Catalog 1307819
Catalog 1307819
Revised 6-04
Revised 6-04
Revised 6-04
www.tycoelectronics.com
www.tycoelectronics.com
www.tycoelectronics.com
Self-retaining contacts
provide permanent
connection with quick
connect and disconnect
Fast, easy installation with
no additional locking
hardware required
Mates with .025 [0.64]
square posts in a variety
of configurations
Single- and double-row
configurations in up to
20 positions on .100 [2.54]
centers
Modular design permits
end-to-end stacking
(double- row only) for
circuit grouping
Choice of tin or select gold
plating
Housings made of 94V-0
rated glass-filled polyester
Recognized under the
Component Program
of Underwriters
Laboratories Inc.,
File No. E28476
Certified by Canadian
Standards
Association,
File No. LR 7189
Dimensions are in inches and
Dimensions are in inches and
Dimensions are in inches and
millimeters unless otherwise
millimeters unless otherwise
millimeters unless otherwise
specified. Values in brackets
specified. Values in brackets
specified. Values in brackets
are metric equivalents.
are metric equivalents.
are metric equivalents.
AMPMODU Interconnection System
*If post is longer than maximum specified, post tip may butt against wire ends.
Typical Application
Locking Clip Contacts and Housings
Single Row
(Page 225)
Both Ends
Dimension defines .025 x .025 [0.64 x 0.64] portion of post.
Closed
PCBoard
[5.08/7.04]
.200/.277*
(without
housing
(Page 224)
Contact
Single
Dimensions are shown for
Dimensions are shown for
Dimensions are shown for
reference purposes only.
reference purposes only.
reference purposes only.
Specifications subject
Specifications subject
Specifications subject
to change.
to change.
to change.
Extraction
Tool Slot
no. of circuits—
housing size)
(for specified
(Page 226)
Both Ends
Closed
Clearance
Contact
Hole
USA: 1-800-522-6752
USA: 1-800-522-6752
USA: 1-800-522-6752
Canada: 1-905-470-4425
Canada: 1-905-470-4425
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
Mexico: 01-800-733-8926
Mexico: 01-800-733-8926
C. America: 52-55-5-729-0425
C. America: 52-55-5-729-0425
C. America: 52-55-5-729-0425
Sq. Posts
[0.64]
.025
(Page 226)
stacking to
Right End
Open (for
right side)
(Page 226)
stacking to
Open (for
Left End
left side)
South America: 55-11-3611-1514
South America: 55-11-3611-1514
South America: 55-11-3611-1514
Hong Kong: 852-2735-1628
Hong Kong: 852-2735-1628
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
Japan: 81-44-844-8013
Japan: 81-44-844-8013
UK: 44-141-810-8967
UK: 44-141-810-8967
UK: 44-141-810-8967
(with housing)
.273/.350*
[6.93/8.89]
[2.54 x 2.54]
.100 x .100
223
5

Related parts for 1-87483-5

1-87483-5 Summary of contents

Page 1

... Fast, easy installation with no additional locking hardware required Mates with .025 [0.64] square posts in a variety of configurations Single- and double-row configurations positions on .100 [2.54] centers Modular design permits end-to-end stacking (double- row only) for circuit grouping Choice of tin or select gold plating ...

Page 2

... AMP-O-LECTRIC Model “K” machines. Call the Technical Support Center (1-800-522-6752) for part nos. of applicators for use with the AMP-O-LECTRIC Model “G” machines (shown on page 289), as well as other bench machines and fully automatic AMPOMATORlead making machines. Notes: 1. These contacts must be crimped in accordance with Tyco ElectronicsSpecification No order to function properly in a connector housing. Notes: 2 ...

Page 3

... A C Typ. .085 [2.16] .100 Typ. [2.54] B Note: Housing illustrated above is the “Both Ends Closed” version. Dimensions .108 [2.74] — .054 [1.37] .216 [5.49] .100 [2.54] .058 [1.47] .316 [8.03] .200 [5.08] ...

Page 4

... Length) .025 [0.64] Sq. Post .270 (Shown for [6.86] Ref. only) .100 [2.54] .100 [2.54] .058 [1.47] Note: Housing illustrated above is the “Both Ends Closed” version. Both Ends Closed Right End Open Housing No. of Dimensions Configuration Pos .116 [2.95] 4 .216 [5.49] 6 ...

Page 5

... Housing configurations include single- and double- rows on .100 [2.54] centerlines Housing options include detent latching, polarization 1-87631-5 D-R Housing, Polarized with Detent and bonded strain relief/ 1-87756-6 Std. Pressure Contacts pull tabs 102387-1 D-R Ejection Housing, Recognized under the Center Polarized Component Program of 1-87756-6 Std ...

Page 6

... AMP-O-LECTRIC Model “K” machines. Call the Technical Support Center (1-800-522-6752) for part nos. of applicators for use with the AMP-O-LECTRIC Model “G” machines (shown on page 289), as well as other bench machines and fully automatic AMPOMATORlead making machines. ...

Page 7

... Plating D—Selectively plated .000050 [0.00127] gold on contact area, with gold flash over .000050 [0.00127] nickel on entire contact Plating E—Selectively plated .000030 [0.00076] gold on contact area, with gold flash over ...

Page 8

... AMP-O-LECTRIC Model “K” machines. Call the Technical Support Center (1-800-522-6752) for part nos. of applicators for use with the AMP-O-LECTRIC Model “G” machines (shown on page 289), as well as other bench machines and fully automatic AMPOMATORlead making machines. ...

Page 9

... Part No. 87077-2 **No marking on housing. (Plugs directly into housing) Notes: 1. Strain reliefs are available and may be purchased separately. Consult Tyco Electronics. Notes: 2. Contact Extraction/Lance Reset Tool No. 843996-3. Catalog 1307819 Dimensions are in inches and ...

Page 10

... Polarized (with Detent Latching) Material: Black thermoplastic, flame retardant Related Product Data s—pages 228-230 Mateable Headers and Posts— pages 129-131 Flexible Film Connectors, Single-Row Pin Assemblies— Catalog 82007 Technical Documents: (pages 294 Product Specification 108-25007, 208-25019, 108-25020, 108-25021 Application Specification ...

Page 11

... AMP, part number and date code stamped on housing where size permits. (for .600 high housings) **No marking on housing. (Plugs directly into housing) Notes: 1.Strain reliefs are available and may be purchased separately. Consult Tyco Electronics. Notes: 2. Contact Extraction/Lance Reset Tool No. 843996-3. Catalog 1307819 ...

Page 12

... AMP, part number and date code stamped on housing where size permits. **No marking on housing or strain relief. Notes: 1. Strain reliefs are available and may be purchased separately. Consult Tyco Electronics. Notes: 2. Contact Extraction/Lance Reset Tool No. 843996-3. Dimensions are shown for ...

Page 13

... AMP, part number and date code stamped on housing and/or strain relief where size permits. **No marking on housing or strain relief. Notes: 1. The Strain Relief/Pull Tab can be bonded to any thermoplastic connector housing. Notes: 2. Strain reliefs may be purchased separately. Notes: 3. Contact Extraction/Lance Reset Tool No. 843996-3. ...

Page 14

... AMP, part number and date code stamped on housing and/or strain relief where size permits. **No marking on housing or strain relief. Notes: 1. The Strain Relief/Pull Tab can be bonded to any thermoplastic connector housing. Notes: 2. Strain reliefs may be purchased separately. Notes: 3 ...

Page 15

... AMPMODU Interconnection System Mod IV Wire-Applied Housings, Double-Row, .100 x .100 [2.54 x 2.54] Centerline Center Polarized Position No. 1 Indicator Material: Black thermoplastic, flame retardant Related Product Data: .120 Contacts—pages 228-230 [3.05] Mateable Headers and Posts: Low Profile Shrouded Headers, Double-Row, Straight or Right- ...

Page 16

... Mates with .025 [0.64] square posts Dual cantilever contact beams for reliable matings Locking retention latch provides 3 lb [13. retention force Unique locking latch design helps prevent latch from protruding through latch window Contacts snap into ...

Page 17

... Plating B Plating C *For use with Model “K” machines. Call the Tooling/Technical Assistance Center (1-800-722-1111) for part nos. of applicators for use with the Model “G” machines (shown on page 289), as well as other bench machines and fully automatic AMPOMATOR lead making machines. ...

Page 18

... Values in brackets specified. Values in brackets www.tycoelectronics.com www.tycoelectronics.com are metric equivalents. are metric equivalents. AMPMODU Interconnection System Short Point Wire-Applied Housings, Double-Row, Non-Polarized, .100 x .100 [2.54 x 2.54] Centerline A B .049 [1.24] X .100 Typ. X [2.54] .100 [2 ...

Page 19

... AMPMODU Interconnection System Short Point Wire-Applied Housings, Double-Row, Polarized, .100 x .100 [2.54 x 2.54] Centerline Material: Black thermoplastic, flame retardant, 94V-0 rated .049 [1.24] Related Product Data: Performance Characteristics— page 238 Contacts—page 239 .100 Mateable Headers—pages 121, 122, [2.54] ...

Page 20

... Contact Termination Resistance—15 milliohms (max.) Dielectric Withstanding Voltage— At Sea Level–600 VAC, rms At 70,000 Ft. [21 336 m]–225 VAC, rms Insulation Resistance— 5,000 megohms (min.) Environmental Characteristics Operating Temperature— -65°C to +105°C Vibration— ...

Page 21

... Insulation Displacement (Used in all Receptacle Assemblies) 1 Mating AMPMODU Double-Row Shrouded Header Assemblies must have .318 [8.08] mating post length and .150 [3.81] dimension from centerline of last 1 post to inside of end shroud wall. 2 Surface Mount Right-Angle and Vertical Headers are also available (see pages 269 and 270) ...

Page 22

... Crimp Snap-In Pin Contact (Used with Unloaded Housings— See page 273) USA: 1-800-522-6752 USA: 1-800-522-6752 South America: 55-11-3611-1514 South America: 55-11-3611-1514 Canada: 1-905-470-4425 Canada: 1-905-470-4425 Hong Kong: 852-2735-1628 Hong Kong: 852-2735-1628 Mexico: 01-800-733-8926 Mexico: 01-800-733-8926 Japan: 81-44-844-8013 Japan: 81-44-844-8013 C ...

Page 23

... Plating C—.000100 [0.00254] bright tin-lead over .000050 [0.00127] nickel on entire contact Note: Insulation displacement contacts accept an insulation diameter of .030 [0.76] min. to .054 [1.37] max. with an insulation wall thickness of .015 [0.38] max. Mating post length for preloaded .200 [5.08] min., .250 [6.35] max. ...

Page 24

... Notes: 1. Receptacle assemblies are furnished with strip contacts partially inserted into housing—contacts latched into “preload” windows. Contacts are fully inserted into housings automatically when terminated with Tyco Electronics application machines, or manually when terminated with AMP pistol grip hand tool. ...

Page 25

... AMPMODU Interconnection System MTE Receptacle Assemblies—Polarized/Latching, Single-Row, .100 [2.54] Centerline Preassembled housings in strip form are available in positions 2 thru 12. For ease of handling, positions 2 thru 5 are recommended when using the Tyco Electronics Manual Pistol Grip Material and Finish: Housing—Black thermoplastic, 94V-0 rated Contacts— ...

Page 26

... Notes: 1. Receptacle assemblies are furnished with strip contacts partially inserted into housing—contacts latched into “preload” windows. Contacts are fully inserted into housings automatically when terminated with AMP application machines, or manually when terminated with AMP pistol grip hand tool. ...

Page 27

... Tyco Electronics Manual Pistol Grip Tool. Material and Finish: Housing—Black thermoplastic, 94V-0 rated s—Phosphor Bronze, plated as follows: Plating A—Duplex plated .000030 [0.00076] gold on contact area, .000050 [0.00127] min. tin-lead in crimp area, with entire contact underplated .000050 [0.00127] nickel Plating B— ...

Page 28

... Notes: 1. Receptacle assemblies are furnished with strip contacts partially inserted into housing—contacts latched into “preload” windows. Contacts are fully inserted into housings automatically when terminated with AMP application machines, or manually when terminated with AMP pistol grip hand tool. ...

Page 29

... Notes: 1. Receptacle assemblies are furnished with strip contacts partially inserted into housing—contacts latched into “preload” windows. Contacts are fully inserted into housings automatically when terminated with application machines, or manually when terminated with pistol grip hand tool. 2. High pressure receptacle contacts can be made available in other housing styles and position sizes. ...

Page 30

... Mateable AMPMODU Products ( Receptacle Assemblies Installed in Double-Row Coupling Shrouds): Headers, Shrouded, Double-Row (.318 [8.08] mating post length, .150 [3.81] end dimension)— 135, 137, 141, 145, 146, 148- 150, 166 Application Tooling—pages 291, 292 Performance Specifications— page 242 Technical Documents (pages 5 ...

Page 31

... Plating C—.000100 [0.00254] bright tin-lead over .000050 [0.00127] nickel on entire contact Note: Insulation displacement contacts accept an insulation diameter of .030 [0.76] min. to .054 [1.37] max. with an insulation wall thickness of .015 [0.38] max. Related Product Data: Mateable AMPMODU Products: Receptacle Assemblies (Polarized/Latching)— ...

Page 32

... Notes: 1. Pin assemblies are furnished with strip contacts partially inserted into housing—contacts latched into “preload” windows. Contacts are fully inserted into housings automatically when terminated with application machines, or manually when terminated with pistol grip hand tool. 2. Use Extraction/Lance Reset Tool No. 843477-1 to remove pin contacts. ...

Page 33

... AMPMODU Interconnection System MTE Pin Assemblies—Guide Ribs, Single-Row, .100 [2.54] Centerline Preassembled housings in strip form are available in positions 2 thru 12. For ease of handling, positions 2 thru 5 are recommended when using the Tyco Electtronics Manual Pistol Grip Tool. Material and Finish: Housing—Black thermoplastic, 94V-0 rated Contacts— ...

Page 34

... Notes: 1. Pin assemblies are furnished with strip contacts partially inserted into housing—contacts latched into “preload” windows. Contacts are fully inserted Notes into housings automatically when terminated with application machines, or manually when terminated with pistol grip hand tool. ...

Page 35

... Pin Assemblies with Guide Ribs, Installed in Panel Mount Pin Shroud (Refer to pages 255, 256 & 259) Headers, Polarized/Latching, Straight and Right Angle Post, with or without Holddown (See pages 261-270) South America: 55-11-3611-1514 Hong Kong: 852-2735-1628 Japan: 81-44-844-8013 UK: 44-141-810-8967 5 257 ...

Page 36

... Assemblies with Guide Ribs (Refer to pages 249 & 250) 1 Mating AMPMODU Double-Row Shrouded Headers must have .318 [8.08] mating post length and .150 [3.81] dimension from centerline 1 of last post to inside of end shroud wall. Typical Application of Double-Row Coupling Shroud and Mating AMPMODU Products ...

Page 37

... Catalog 1307819 Dimensions are in inches and Revised 6-04 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. A Position No. 1 Identification .320 [8.13] .270 [6.86] B Dimensions Panel Mount No. of Pin Shroud Pos .625 [15.88] ...

Page 38

... Panel Mount Pin Shroud Rear of Panel Receptacle Assembly, Polarized/Latching (Refer to pages 247 & 248) USA: 1-800-522-6752 USA: 1-800-522-6752 South America: 55-11-3611-1514 South America: 55-11-3611-1514 Canada: 1-905-470-4425 Canada: 1-905-470-4425 Hong Kong: 852-2735-1628 Hong Kong: 852-2735-1628 Mexico: 01-800-733-8926 Mexico: 01-800-733-8926 Japan: 81-44-844-8013 Japan: 81-44-844-8013 C ...

Page 39

... Dia. Typ. [1.02±0.08] (for Retention Tails) Recommended PC Board Hole Layout *±.003 [±0.08]; tolerances not to accumulate within one connector pattern. Note: Swaged retention tails are provided in a minimum of two locations per header. Dimensions are shown for USA: 1-800-522-6752 reference purposes only. ...

Page 40

... Notes: 1.Selectively loaded headers are available, consult Tyco Electronics. 2. Use Keying Tool No. 91417-1 to remove post for keying. 5 262 Catalog 1307819 Catalog 1307819 Dimensions are in inches and ...

Page 41

... Dia. Typ. [0.89±0.08] C Recommended PC Board Hole Layout (PC board thickness (for Holddown Feature) is .062±.008 [1.57±0.20]) *±.003 [±0.08]; tolerance not to accumulate within one connector pattern. .535 [13.59] Position No. 1 Indicator .100 .100 Typ ...

Page 42

... Notes: 1.Selectively loaded headers are available, consult Tyco Electronics. 2. Use Keying Tool No. 91417-1 to remove post for keying. 5 264 Catalog 1307819 Catalog 1307819 Dimensions are in inches and ...

Page 43

... Other Mateable Connectors: Flexible Film Connectors— Catalog 82007 Technical Documents ( *±.003 [±0.08]; tolerances not to accumulate within one connector pattern. pages 295, 296): Note: Swaged retention tails are provided in a minimum of two locations per header. Product Specification ...

Page 44

... Dia. Typ. [1.02±0.08] Plated-Thru Hole Header Profile (Shown for orientation purposes only) Recommended PC Board Hole Layout (Stencil Thickness = .010 [0.25]) *±.003 [±0.08] tolerance not to accumulate within one connector pattern Dimensions No. of Pos .300 [7.62] .220 [5.59] 3 ...

Page 45

... Dia. Typ. [1.02±0.08] Receptacle Assemblies Plated-Thru Hole (for Retention Tails )— pages 247, 248 Receptacle Assemblies with Guide Ribs (installed in Single-Row Note: Swaged retention tails in Holddown versions only. Retention tails are provided in a minimum of two locations Coupling Shroud)—pages 249, 250, per header ...

Page 46

... Related Product Data: Mateable AMPMODU Receptacle Assemblies ( )— pages 247, 248 Receptacle Assemblies with Guide Ribs (installed in Single-Row Coupling Shroud)—pages 249, 250, 252, 257 Other Mateable Connectors: Flexible Film Connectors— ...

Page 47

... Housing—High temperature thermoplastic, Color - Black Posts—Copper Alloy, plated as follows: Plating A—Duplex plated .000030 [.00076] gold on contact area, .000100 [.00254] min. tin-lead on solder area, with entire post underplated .000050 [.00127] nickel. Plating B—Duplex plated .000015 [.00038] gold on contact area, .000100 [.00254] min. tin-lead on ...

Page 48

... Dimensions are shown for Dimensions are shown for USA: 1-800-522-6752 USA: 1-800-522-6752 reference purposes only. reference purposes only. Canada: 1-905-470-4425 Canada: 1-905-470-4425 Specifications subject Specifications subject Mexico: 01-800-733-8926 Mexico: 01-800-733-8926 to change. to change. C. America: 52-55-5-729-0425 C. America: 52-55-5-729-0425 .230 [5.84] Pick and Place Cap Section K-K .088± ...

Page 49

... Colored Polarized Latching Receptacle Mates to Colored Vertical Header with PC Board orientation: Material and Finish: Housing – Color Thermoplastic, 94V-0 rated Contact/post – Copper alloy, plated .000100-.000200 [0.00254-0.00508] tin-lead over .000050 [0.00127] nickel on entire contact/post. Technical Documents ( 295, 296): Product Specification ...

Page 50

... Model “K” machines. Call the Technical Support Center (1-800-522-6752) for part nos. of applicators for use with the Model “G” machines (shown on page 289), as well as other bench machines and fully automatic AMPOMATOR lead making machines. ...

Page 51

... Plating C *For use with AMP-O-LECTRIC Model “K” machines. Call Technical Support Center (1-800-522-6752) for part nos. of applicators for use with the AMP-O-LECTRIC Model “G” machines (shown on page 289), as well as other bench machines and fully automatic AMPOMATORlead making machines. ...

Page 52

... Max. Mating Force— High pressure - 26 oz. [7.23 N] Standard pressure - 9 oz. [2.50 N] Min. Unmating Force—- High pressure - 5 oz. [1.39 N] Standard pressure - 1.5 oz. [0.417 N] Contact Retention in Housing— 5 lb. [22.24 N] per contact min. South America: 55-11-3611-1514 South America: 55-11-3611-1514 Hong Kong: 852-2735-1628 ...

Page 53

... Housings Pre-loaded with Standard Pressure Contacts .600 [15.24] Material and Finish: Housing—Black thermoplastic, flame retardant s—Copper alloy, duplex plated .050 .000030 [0.00076] gold on contact area, [1.27] .000050 [0.00127] min. tin-lead in crimp area, with entire contact underplated .000050 [0.00127] nickel Related Product Data: Mateable Connectors— ...

Page 54

... Tyco Electronics Part No. and date code stamped on housing where size permits. Note: Contact Extraction/Lance Reset Tool No. 843477-3, see page 284. Part No. 87077-2 (Plugs directly into housing) Dimensions are shown for ...

Page 55

... Revised 6-04 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents Polarizing Cover (Mates with AMPMODU 4-sided shrouded headers. Refer to pages 133, 139, 143, 147.) .750 [19.05 Ejection Cover (Mates with AMP-LATCH universal ejection style pin headers equipped with latching ears, Part No ...

Page 56

... Specifications subject Specifications subject to change. to change Ejection Cover (Mates with AMP-LATCH universal ejection style pin headers equipped with latching ears, Part No. 102185-2 (with push tabs) or Part No. 102312-2 (without push tabs), see Tyco Electronics 1.120 [28.45] .095 [2.41] Typ. ...

Page 57

... C. America: 52-55-5-729-0425 Photo 110928 Photo 98187 Shields for right-angle headers have integral cantilever beams which provide good contact with the mating shielded MT receptacle assembly, without the use of a separate RF gasket. 5 279 South America: 55-11-3611-1514 Hong Kong: 852-2735-1628 Japan: 81-44-844-8013 UK: 44-141-810-8967 ...

Page 58

... Shell Halves—Copper alloy, .020 [0.51] thick; pretinned .000030 [0.00076] min. Related Product Data: Double-Row MT Receptacle Assemblies—pages 275, 276 Non-Polarizing Covers (Part No. Series 102541 with back cover 102536 or 102823)— pages 277, 278 Shield Ferrules—page 282 Technical Documents ( pages 295, 296): ...

Page 59

... Instruction Sheet 408-6532 No. of Pos Notes: 1. Match shield size to number of connector positions. Notes: 2. Hole is provided in 26 through 60-position cable shields for application of optional cable tie pull ring after Notes: 2. assembly. Catalog 1307819 Dimensions are in inches and Revised 6-04 millimeters unless otherwise specified ...

Page 60

... Model “K” machines. Call the Tyco Electronics Technical Support Center (1-800-522-6752) for part nos. of applicators for use with the AMP-O-LECTRIC Model “G” machines (also shown on page 289), as well as other bench machines and fully automatic AMPOMATORlead making machines. Notes: 1. Ferrules are used with shielding kits shown on pages 280 & ...

Page 61

... D ±.003 [1.02±0.08] [±0.08] (All holes) ±.003 2D [±0.08] for 6, 8 and 10 Positions D - Contact centerline is .100 [2.54]; ±.003 [0.08] tolerances not to accumulate within one connector pattern. Dimensions .200 [5.08] .430 [10.92] .510 [12.95] 8 ...

Page 62

... Contacts Material and Finish: Copper alloy, duplex plated .000030 [0.00076] gold on contact area, .000100-.000200 [0.00254-0.00508] tin-lead in crimp area, with entire contact underplated .000050 [0.00127] nickel Related Product Data: Performance Characteristics— page 274 Application Tooling—pages 290-293 Technical Documents ( 295, 296): ...

Page 63

... Recognized under the designed to mate with .025 Component Program of [0.64] posts. When used Underwriters individually, they will mate Laboratories Inc., with posts as short as .125 File No. E28476 [3.18] and when used in a housing, they will mate with Certified by Canadian .140 [3.55] long posts. Standards ...

Page 64

... AMPMODU Interconnection System AMP Mini-Tandem Spring Housings, Single-Row .550 [13.97] .050 [1.27] A Max. .100 [2.54] B Spaces @ .100 [2.54 Minimum mating post length is .140 [3.55]. No. of Dimensions Pos .200 [5.08] 3 .300 [7.62] 4 .400 [10.16] 5 .500 [12.70] 7 ...

Page 65

... A Max. .200 [5.08] .100 .050 [2.54] [1.27] B Spaces @ .100 [2.54 Minimum mating post length is .140 [3.55]. Dimensions A B .200 [5.08] 1 .300 [7.62] 2 .400 [10.16] 3 .500 [12.70] 4 .600 [15.24] 5 .800 [20.32 ...

Page 66

... AMP-O-LECTRIC Model “K” machines. Call the Tooling/Technical Assistance Center (1-800-522-6752) for part nos. of applicators for use with the AMP-O-LECTRIC Model “G” machines (shown on page 289), as well as other bench 5 machines and fully automatic AMPOMATOR lead making machines. ...

Related keywords