Specifications of G3PA-420B-VD-2DC12-24

Load Voltage Rating
528 V
Relay Type
Solid State
Termination Style
Crimp
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Specifications
■ Ratings (at an Ambient Temperature of 25°C)
Input
Output
Refer to Engineering Data for further details.
G3PA-210B-VD
G3PA-220B-VD
G3PA-240B-VD
G3PA-260B-VD
G3PA-210BL-VD
G3PA-220BL-VD
G3PA-240BL-VD
G3PA-260BL-VD
G3PA-210B-VD
G3PA-220B-VD
G3PA-240B-VD
G3PA-260B-VD
G3PA-420B-VD
G3PA-430B-VD
G3PA-420B-VD-2
G3PA-430B-VD-2
G3PA-450B-VD-2
G3PA-210B(L)-VD
G3PA-220B(L)-VD
G3PA-240B(L)-VD
G3PA-260B(L)-VD
G3PA-420B-VD
G3PA-430B-VD
G3PA-420B-VD-2
G3PA-430B-VD-2
G3PA-450B-VD-2
Model
Model
5 to 24 VDC
5 to 24 VDC
24 VAC
12 to 24 VDC
24 to 240 VAC (50/60 Hz) 19 to 264 VAC (50/60 Hz) 0.1 to 10 A at 40°C
180 to 400 VAC (50/60 Hz) 150 to 440 VAC (50/60 Hz) 0.5 to 20 A at 30°C
200 to 480 VAC (50/60 Hz) 180 to 528 VAC (50/60 Hz) 0.5 to 20 A at 30°C
Rated voltage
Rated load voltage
4 to 30 VDC
4 to 30 VDC
19.2 to 26.4 VAC
9.6 to 30 VDC
Operating Voltage
range
Load voltage range
7 mA max.
20 mA max.
1.4 kΩ±20%
7 mA max.
Input current
impedance
0.1 to 20 A at 40°C
0.5 to 40 A at 40°C
0.5 to 60 A at 40°C
0.5 to 30 A at 30°C
0.5 to 30 A at 30°C
0.5 to 50 A at 30°C
Load current
4 VDC max.
4 VDC max.
19.2 VAC max.
9.2 VDC max.
Must operate voltage
150 A (60 Hz, 1 cycle) 600 V (V
220 A (60 Hz, 1 cycle)
440 A (60 Hz, 1 cycle)
440 A (60 Hz, 1 cycle)
220 A (60 Hz, 1 cycle) 1,000 V (V
440 A (60 Hz, 1 cycle)
220 A (60 Hz, 1 cycle) 1,200 V (V
440 A (60 Hz, 1 cycle)
440 A (60 Hz, 1 cycle)
Inrush current
Voltage level
1 VDC min.
1 VDC min.
4.8 VAC min.
1 VDC min.
Must release voltage
(reference value)
V
DRM
G3PA
DRM
DRM
DRM
)
)
)
3