24LC01BH-E/ST Microchip Technology, 24LC01BH-E/ST Datasheet - Page 10

no-image

24LC01BH-E/ST

Manufacturer Part Number
24LC01BH-E/ST
Description
1K, 128 X 8 SERIAL EE, 2.5V EXT, 1/2 ARRAY WP 8 TSSOP 4.4mm TUBE
Manufacturer
Microchip Technology
Datasheet

Specifications of 24LC01BH-E/ST

Format - Memory
EEPROMs - Serial
Memory Type
EEPROM
Memory Size
1K (128 x 8)
Speed
400kHz
Interface
I²C, 2-Wire Serial
Voltage - Supply
2.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Package / Case
8-TSSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
24AA01H/24LC01BH
8.0
Read operations are initiated in the same way as write
operations, with the exception that the R/W bit of the
slave address is set to ‘
of read operations: current address read, random read
and sequential read.
8.1
The 24XX01H contains an address counter that
maintains the address of the last word accessed,
internally incremented by ‘
access (either a read or write operation) was to
address
would access data from address
the slave address with R/W bit set to ‘
issues an acknowledge and transmits the 8-bit data
word. The master will not acknowledge the transfer, but
does generate a Stop condition and the 24XX01H
discontinues transmission (Figure 8-1).
8.2
Random read operations allow the master to access
any memory location in a random manner. To perform
this type of read operation, the word address must first
be set. This is accomplished by sending the word
address to the 24XX01H as part of a write operation.
Once the word address is sent, the master generates
a Start condition following the acknowledge. This
terminates the write operation, but not before the inter-
nal Address Pointer is set. The master then issues the
control byte again, but with the R/W bit set to a ‘
24XX01H will then issue an acknowledge and
transmits the 8-bit data word. The master will not
acknowledge the transfer, but does generate a Stop
condition and the 24XX01H discontinues transmission
(Figure 8-2).
FIGURE 8-1:
DS22104A-page 10
READ OPERATION
Current Address Read
Random Read
n
, the next current address read operation
Bus Activity
Master
SDA Line
Bus Activity
x = “don’t care”
CURRENT ADDRESS READ
1
’. There are three basic types
1
’. Therefore, if the previous
n + 1
R
S
T
A
T
S
1
. Upon receipt of
’, the 24XX01H
1 0 1 0 x x x 1
1
’. The
Control
Byte
Select
Block
Bits
8.3
Sequential reads are initiated in the same way as a
random read, except that once the 24XX01H transmits
the first data byte, the master issues an acknowledge
(as opposed to a Stop condition in a random read). This
directs the 24XX01H to transmit the next sequentially
addressed 8-bit word (Figure 8-3).
To provide sequential reads the 24XX01H contains an
internal Address Pointer which is incremented by one
at the completion of each operation. This Address
Pointer allows the entire memory contents to be serially
read during one operation.
8.4
The 24XX01H employs a V
which disables the internal erase/write logic if the V
is below 1.5V at nominal conditions.
The SCL and SDA inputs have Schmitt Trigger and
filter circuits which suppress noise spikes to assure
proper device operation even on a noisy bus.
A
C
K
Sequential Read
Noise Protection
Data (n)
© 2008 Microchip Technology Inc.