AD5271BCPZ-20-RL7 Analog Devices Inc, AD5271BCPZ-20-RL7 Datasheet - Page 19

no-image

AD5271BCPZ-20-RL7

Manufacturer Part Number
AD5271BCPZ-20-RL7
Description
256 Tap 5v 50tp, 1% R-tol MSOP SPI I.C.
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD5271BCPZ-20-RL7

Resistance (ohms)
20K
Taps
256
Number Of Circuits
1
Temperature Coefficient
5 ppm/°C Typical
Memory Type
Non-Volatile
Interface
SPI Serial
Voltage - Supply
2.7 V ~ 5.5 V, ±2.5 V ~ 2.75 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
10-TFSOP, 10-MSOP (0.118", 3.00mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
AD5271BCPZ-20-RL7
AD5271BCPZ-20-RL7TR
Command
Number
0
1
2
3
4
5
6
7
8
9
RDAC AND 50-TP READ OPERATION
A serial data output SDO pin is available for readback of the
internal RDAC register or 50-TP memory contents. The
contents of the RDAC register can be read back through SDO
by using Command 2 (see Table 11). Data from the RDAC
register is clocked out of the SDO pin during the last 10 clocks
of the next SPI operation.
It is possible to read back the contents of any of the 50-TP
memory registers through SDO by using Command 5. The
lower six LSB bits, D0 to D5 of the data byte, select which
memory location is to be read back, as shown in Table 13.
Table 11. Command Operation Truth Table
1
2
3
4
X is don’t care.
AD5271 = don’t care.
See Table 15 for 50-TP memory map.
See Table 14 for bit details.
3
4
Command[DB13:DB10]
C3
0
0
0
0
0
0
0
0
1
1
C2
0
0
0
0
1
1
1
1
0
0
C1
0
0
1
1
0
0
1
1
0
0
C0
0
1
0
1
0
1
0
1
0
1
D9
X
D9
X
X
X
X
X
X
X
X
D8
X
D8
X
X
X
X
X
X
X
X
D7
X
D7
X
X
X
X
X
X
X
X
D6
X
D6
X
X
X
X
X
X
X
X
Rev. E | Page 19 of 24
Data[DB9:DB0]
D5
X
D5
X
X
X
D5
X
X
X
X
D4
X
D4
X
X
X
D4
X
X
X
X
Data from the selected memory location is clocked out of the
SDO pin during the next SPI operation. A binary encoded
version address of the most recently programmed wiper memory
location can be read back using Command 6 (see Table 11). This
can be used to monitor the spare memory status of the 50-TP
memory block.
Table 12 provides a sample listing for the sequence of serial data
input (DIN) words with the serial data output appearing at the
SDO pin in hexadecimal format for a write and read to both the
RDAC register and the 50-TP memory (Memory Location 20).
D3
X
D3
X
X
X
X
X
X
X
D3
1
D2
X
D2
X
X
X
X
D2
X
X
D2
D1
X
D1
X
X
X
X
D1
X
X
D1
2
D0
X
D0
X
X
X
X
D0
X
D0
D0
2
Operation
NOP: do nothing.
Write contents of serial register
data to RDAC.
Read contents of RDAC wiper
register.
Store wiper setting: store RDAC
setting to 50-TP.
Software reset: refresh RDAC with
last 50-TP memory stored value.
Read contents of 50-TP from SDO
output in the next frame.
Read address of last 50-TP
programmed memory location.
Write contents of serial register
data to control register.
Read contents of control register.
Software shutdown.
D0 = 0; normal mode.
D0 = 1; device placed in shutdown
mode.
AD5270/AD5271

Related parts for AD5271BCPZ-20-RL7