ADG633YRUZ-REEL7 Analog Devices Inc, ADG633YRUZ-REEL7 Datasheet - Page 11

no-image

ADG633YRUZ-REEL7

Manufacturer Part Number
ADG633YRUZ-REEL7
Description
2:1 MUX, +/-5V Supply Rate To +125? I.C.
Manufacturer
Analog Devices Inc
Datasheet

Specifications of ADG633YRUZ-REEL7

Function
Switch
Circuit
3 x SPDT
On-state Resistance
75 Ohm
Voltage Supply Source
Single, Dual Supply
Voltage - Supply, Single/dual (±)
2 V ~ 12 V, ±2 V ~ 6 V
Current - Supply
0.01µA
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-TSSOP (0.173", 4.40mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
TERMINOLOGY
V
Most positive power supply potential.
V
Most negative power supply potential.
I
Positive supply current.
I
Negative supply current.
GND
Ground (0 V) reference.
S
Source terminal. Can be an input or output.
D
Drain terminal. Can be an input or output.
A
Logic control input.
EN
Active low digital input. When EN is high, the device is disabled
and all switches are off. When EN is low, the Ax logic inputs
determine the on switches.
V
Analog voltage on Terminal D and Terminal S.
R
Ohmic resistance between Terminal D and Terminal S.
ΔR
On-resistance match between any two channels, that is,
R
R
Flatness is defined as the difference between the maximum and
minimum value of on resistance as measured over the specified
analog signal range.
I
Source leakage current with the switch off.
I
Drain leakage current with the switch off.
I
Channel leakage current with the switch on.
V
Maximum input voltage for Logic 0.
DD
SS
S(OFF)
D(OFF)
D(ON)
ON
ONMAX
FLAT(ON)
DD
SS
X
D
INL
, V
ON
, I
S
S(ON)
− R
ONMIN
.
Rev. A | Page 11 of 16
V
Minimum input voltage for Logic 1.
I
Input current of the digital input.
C
Off switch source capacitance. Measured with reference to
ground.
C
Off switch drain capacitance. Measured with reference to
ground.
C
On switch capacitance. Measured with reference to ground.
C
Digital input capacitance.
t
Delay between applying the digital control input and the output
switching on (see Figure 26).
t
Delay between applying the digital control input and the output
switching off (see Figure 26).
t
On time, measured between 80% points of both switches when
switching from one address state to another.
Charge Injection
A measure of the glitch impulse transferred from the digital
input to the analog output during switching.
Off Isolation
A measure of unwanted signal coupling through an off switch.
Crosstalk
A measure of unwanted signal that is coupled through from one
channel to another as a result of parasitic capacitance.
Bandwidth
The frequency at which the output is attenuated by 3 dB.
On Response
The frequency response of the on switch.
Insertion Loss
The loss due to the on resistance of the switch.
INL
ON
OFF
BBM
S(OFF)
D(OFF)
D(ON)
IN
INH
, I
( EN )
( EN )
INH
, C
S(ON)
ADG633

Related parts for ADG633YRUZ-REEL7