EPM9320LC84-20 Altera, EPM9320LC84-20 Datasheet - Page 35

no-image

EPM9320LC84-20

Manufacturer Part Number
EPM9320LC84-20
Description
MAX 9000
Manufacturer
Altera
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EPM9320LC84-20
Manufacturer:
WSI
Quantity:
550
Part Number:
EPM9320LC84-20
Manufacturer:
ALTERA
0
Part Number:
EPM9320LC84-20
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EPM9320LC84-20N
Manufacturer:
ALTERA
Quantity:
830
Part Number:
EPM9320LC84-20N
Manufacturer:
ALTERA
Quantity:
1 126
Part Number:
EPM9320LC84-20N
Manufacturer:
ALTERA
0
Notes to tables:
(1)
(2)
(3)
(4)
(5)
(6)
Power
Consumption
Altera Corporation
t
t
t
t
t
t
t
t
Symbol
LOCAL
ROW
COL
DIN_D
DIN_CLK
DIN_CLR
DIN_IOC
DIN_IO
Table 24. Interconnect Delays
These values are specified under the MAX 9000 device recommended operating conditions, shown in
page
See
delays.
This parameter is a guideline that is sample-tested only. It is based on extensive device characterization. This
parameter applies for both global and array clocking as well as both macrocell and I/O cell registers.
Measured with a 16-bit loadable, enabled, up/down counter programmed in each LAB.
The t
The t
or timing analysis is required to determine actual worst-case performance.
Application Note 77 (Understanding MAX 9000 Timing)
ROW ,
27.
LPA
LAB local array delay
FastTrack row delay
FastTrack column delay
Dedicated input data delay
Dedicated input clock delay
Dedicated input clear delay
Dedicated input I/O register
clock delay
Dedicated input I/O register
control delay
parameter must be added to the t
t
COL,
Parameter
and t
IOC
delays are worst-case values for typical applications. Post-compilation timing simulation
The supply power (P) versus frequency (f
be calculated with the following equation:
P = P
The P
and switching frequency, can be calculated using the guidelines given in
Application Note 74 (Evaluating Power for Altera
depends on the switching frequency and the application logic.
The I
I
CCINT
CCINT
INT
IO
(6)
(6)
value, which depends on the device output load characteristics
+ P
= (A
value is calculated with the following equation:
IO
Conditions
= I
f
LOCAL
MAX
CCINT
MAX 9000 Programmable Logic Device Family Data Sheet
MC
parameter for macrocells running in low-power mode
TON
tog
for more information on test conditions for t
V
) + [B
LC
CC
Min
)
+ P
-10
IO
(MC
Max
0.5
0.9
0.9
4.0
2.7
4.5
2.5
5.5
DEV
MAX
Speed Grade
Min
– MC
) for MAX 9000 devices can
-15
Devices). The I
TON
Max
0.5
1.4
1.7
4.5
3.5
5.0
3.5
6.0
)] + (C MC
Min
-20
CCINT
PD1
Max
Table 15 on
0.5
2.0
3.0
5.0
4.0
5.5
4.5
6.5
USED
and t
value
Unit
ns
ns
ns
ns
ns
ns
ns
ns
PD2
.
35

Related parts for EPM9320LC84-20