KSZ8041NL AM TR Micrel Inc, KSZ8041NL AM TR Datasheet - Page 53

Physical Layer Transceiver 10/100BASE-T/TX ( ) - Automotive Qualified

KSZ8041NL AM TR

Manufacturer Part Number
KSZ8041NL AM TR
Description
Physical Layer Transceiver 10/100BASE-T/TX ( ) - Automotive Qualified
Manufacturer
Micrel Inc
Datasheet

Specifications of KSZ8041NL AM TR

Lead Free Status / Rohs Status
Compliant
Micrel, Inc.
Selection of Isolation Transformer
A 1:1 isolation transformer is required at the line interface. An isolation transformer with integrated common-mode chokes
is recommended for exceeding FCC requirements.
The Table 17 gives recommended transformer characteristics.
Selection of Reference Crystal
September 2010
Parameter
Turns ratio
Open-circuit inductance (min.)
Leakage inductance (max.)
Inter-winding capacitance (typ.)
D.C. resistance (typ.)
Insertion loss (max.)
HIPOT (min.)
Characteristics
Frequency
Frequency tolerance (max)
Load capacitance
Series resistance
Magnetic Manufacturer
Bel Fuse
Bel Fuse (Mag Jack)
Bel Fuse (Mag Jack)
Delta
LanKom
Pulse
Pulse (low cost)
Transpower
TDK (Mag Jack)
Table 19. Typical Reference Crystal Characteristics
Table 18. Qualified Single Port Magnetics
Table 17. Transformer Selection Criteria
Part Number
S558-5999-U7
SI-46001
SI-50170
LF8505
LF-H41S
H1102
H1260
HB726
TLA-6T718
12pF
Value
1 CT : 1 CT
350μH
0.4μH
0.9Ω
-1.0dB
1500Vrms
Value
53
±50
20
40
25
Auto MDI-X
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Test Condition
100mV, 100kHz, 8mA
1MHz (min.)
0MHz – 65MHz
Number of Port
1
1
1
1
1
1
1
1
1
Units
MHz
ppm
pF
Ω
M9999-090910-1.4
KSZ8041NL/RNL