no-image

FLUKE-113

Manufacturer Part Number
FLUKE-113
Description
MULTIMETER UTILITY TRU-RMS 600V
Manufacturer
Fluke Electronics
Series
11xr
Type
Digital (DMM)r
Datasheets

Specifications of FLUKE-113

Includes
Battery, Test Leads
Style
Handheld
Display Digits
3.75
Display Type
LCD, Bar Graph
Display Count
6000
Function
Voltage, Resistance, Capacitance
Functions, Extra
Continuity, Diode Test
Features
Backlight, Hold, Min/Max, Sleep
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Lead free / RoHS compliant by exemption
Other names
3078875
MIN MAX Recording Accuracy and Response Time
Function
Specified accuracy of the measurement function ±40 counts in kChek for
changes >500 ms in duration, ±12 counts in Ohms for changes >325 ms in
duration. Typical 100 ms response to 80 %. Response time not specified for
Capacitance.
k Chek
k Chek
R
R
Ω
Ω
Open Circuit Test Voltage
Common Mode Rejection Ratio (1 kΩ Unbalanced)
<2.7 V dc
<2.7 V dc
Input Impedance (Nominal)
>60 dB at dc, 50 or 60 Hz
Short Circuit Current
~3 kΩ <300 pF
<350 μA
<1.0 mA
Full Scale Voltage
2.000 V dc
<0.7 V dc