T5-1000 USA Fluke Electronics, T5-1000 USA Datasheet - Page 2

TESTER ELECTRICAL 1000V

T5-1000 USA

Manufacturer Part Number
T5-1000 USA
Description
TESTER ELECTRICAL 1000V
Manufacturer
Fluke Electronics
Series
OpenJaw™r
Type
Testerr
Datasheets

Specifications of T5-1000 USA

Includes
Test Leads
Style
Fork
Display Digits
3.5
Display Type
LCD
Display Count
1000
Function
Voltage, Current, Resistance
Functions, Extra
Continuity
Features
Auto Off, Hold
Ranging
Auto
Response
Average
Lead Free Status / RoHS Status
Vendor undefined / Vendor undefined
Other names
614-1050
648219
Auto Off
LO M
OFF
45 min
2 AA
Do not
overtighten
screw
Disconnect test leads from power source
before opening battery door.
Débranchez les cordons d'essai avant
d'ouvrir le couvercle de la pile.
Prima di aprire lo sportello del vano della pila,
scollegare i cavetti dal circuito di
alimentazione.
Die Prüfleiter vor dem Öffnen des
Batteriefachs von der Stromquelle trennen.
Desconecte los conductores de prueba de la
fuente de alimentación antes de abrir la
cubierta de la batería.
Antes de abrir a tampa do compartimento das
pilhas, desconecte os terminais de teste da
fonte de alimentação.
Maak de meetkabels los van de stroombron
voordat u de batterijklep opent.
Koble prøveledningene fra strømkilden før
batteridekselet åpnes.
Søgeledningerne skal tages evt. emne, inden
batteridækslet åbnes.
Irrota koestusjohtimet virtalähteestä ennen
paristolokeron avaamista.
Koppla bort mätsladdarna från strömkällan
innan du öppnar batteriluckan.
W
Warning
Specifications
Specifications subject to change without notice.
Calibration
Temperature
Operating:
Storage:
Altitude
Operating:
Storage:
Relative
Humidity
Battery Type
and Life
RF Field
Specification
Enclosure
Rating
Safety
EMC
Temperature
coefficient
Accuracy
CAT III protects against transients in a fixed equipment
installation such as a distribution panel, and lighting
systems in large buildings.
CAT IV protects against transients from a primary supply
such as an electricity meter or an overhead or
underground utility service.
-10 C to +50 C (14 F to 122 F)
-30 C to +60 C (-22 F to +140 F)
1-year calibration cycle
2000 m (6562 ft)
10,000 m (32808 ft)
0 % to 95 %, 5 C to 30 C
(41 F to 86 F); 0 % to 75 %,
30 C to 40 C
(86 F to 104 F); 0 % to 45 %,
40 C to 50 C
(104 F to 122 F)
AA (2); 360 hours continuous with
alkaline; 125 hours continuous with
zinc chloride
0.5 % full scale + (specified accuracy)
at 3 V / m
IP 52 per IEC 60529, no vacuum
applied
Complies with ANSI/ISA-S82.01-94,
UL classified to IEC 61010, CSA/CAN
C22.2 No.1010.1-92, and EN 61010-
1: 1995.
EN 61326
0.1 x (specified accuracy) / C for <18
significant digits] )
Accuracy is specified for 1 year after
calibration, at 18 C to 28 C
(64 F to 82 F) with relative humidity
to 90 %. AC conversions are ac-
coupled, average responding, and
calibrated to the rms value of a sine
wave input.
C or >28 C (< 64.4 F or > 82.4 F)
( [ % of reading] + [number of least
Replacement Parts
Accessories
To contact Fluke, call:
Visit Fluke's Web site at www.fluke.com.
Function
Certifications:
Replace only with Fluke double-insulated
leads (
probes.
Test Lead Assembly.
Battery Door
Battery Door Screw
?
e
K
L
H5 Belt Holster
TP1 Probe Set, Flat-Blade
AC285 SureGrip™ Alligator Clips
AC220 SureGrip™ Alligator Clips
Service Information Sheet, PN 686953
USA: 1-888-99-FLUKE (1-888-993-5853)
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31 402-675-200
Japan: +81-3-3434-0181
Singapore: +65-738-5655
Anywhere in the world: +1-425-446-5500
T
100.0 A
1000
600 V
600 V
) See "Accessories" for available
T5-600
Range
rms
1000 V CAT III
600 V CAT IV
P
100.0 A
1000
1000 V
1000 V
T5-1000
Range
rms
$
0.1 A
Reso-
lution
1 V
1 V
1
In accordance with
IEC 61010-1, 54CJ
(3 % + 3 digits)
(1 % + 2 digits)
(1 % + 1 digit)
(1.5 % + 2
Accuracy
PN 1626588
PN 1618578
digits)
PN 648029