ACD-41PQ Amprobe, ACD-41PQ Datasheet

DMM CLAMP-ON W/THD

ACD-41PQ

Manufacturer Part Number
ACD-41PQ
Description
DMM CLAMP-ON W/THD
Manufacturer
Amprobe
Series
AutoTect™r
Type
Digital (DMM)r
Datasheet

Specifications of ACD-41PQ

Includes
Battery, Case, Test Leads
Style
Clamp
Display Digits
3.83
Display Type
LCD
Display Count
Varies
Function
Voltage, Current, Resistance, Temperature, Frequency
Functions, Extra
Continuity
Features
Auto Off, Backlight, Hold
Ranging
Auto/Manual
Response
True RMS
Dmm Type
Clamp
Voltage Measuring Range Dc
600V
Voltage Measuring Range Ac
600V
Current Measuring Range Ac
40A To 1000A
Resistance Measuring Range
0-999.9 Ohm
Frequency Measuring Range
5Hz To 500Hz
Trms
YES
Ac Current
40/400/1000 A
Ac Current Basic Accuracy**
±(1.0 % Rdg +5 LSD) @ 50 and 60 Hz
Dc Voltage
600 V
Dc Voltage Basic Accuracy**
±(0.5 % Rdg + 5 LSD)
Ac Voltage
600 V
Ac Voltage Basic Accuracy**
±(1.0 % Rdg + 5 LSD) @ 50 / 60 Hz
Resistance
999.9 Ohms
Resistance Basic Accuracy**
±(1.0 % Rdg + 6 LSD)
Frequency
5 Hz to 500 Hz
Frequency Basic Accuracy**
±(0.5 % Rdg +4 LSD)
Thd-f *
0.0 % to 99.9 %
Thd-f * Basic Accuracy**
1.5 % of Reading + 6d @ Fund Frequency
Active Power (w)
0 to 600 kW
Reactive Power (var)
0 to 600 kVAR
Apparent Power (va)
0 to 600 kVA
Power Factor
0.10 to 0.99
Power Factor Basic Accuracy**
±3 LSD @ Harmonics Fund to 21th
Temperature
-58°F to 572°F (-50°C to 300°C)
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Lead Free Status / RoHS Status
na, Contains lead / RoHS compliant by exemption
Other names
2730760
*THD-R is defined as: (Total Harmonic RMS / Total RMS) x 100%
THD-F is defined as: (Total Harmonic RMS / Fundamental RMS) x 100%
FEATURES
TRMS Measuremaent
AC Current
DC Voltage
AC Voltage
Resistance
Frequency
Active Power (W)
Reactive Power (VAR)
Apparent Power (VA)
Power Factor
THD-R *
THD-F *
Temperature
Hi-Lo Logging
www.AMPROBE.com
0.0% to 99.9%
ACD-40PQ
5400 Points
.
ACD-40PQ & ACD-41PQ
1000A Power Quality Clamp-on with THD Measurement
40.0 / 400.0 / 1000 A
5.00Hz to 500.0Hz
(-50 C to 300 C)
-58 F to 572 F
999.9 Ohms
The ACD-40’s provide a simple and effective way to verify if the electrical system
is affected by harmonics. Add on troubleshooting capabilities with the ACD-40PQ
data logging feature or get complete Power analysis with the ACD-41PQ. Increase
measuring efficiency with an optional PC interface kit.
• TRMS sensing
• Measurements:
• ACD-41PQ also measures Active (W),
• AutoVA - Auto Selection of AC Volts, DC
• Data-logging 5400 points
• Optional PC interface capability
• Audible continuity
• Auto power off
600.0V
600.0V
-Total Harmonics Distortion THD, AC/DC
Voltage up to 600V, AC Current up to
1000A, Resistance, Frequency,
-Temperature
Reactive (VAR) and Apparent (VA) Power
with dual-display Power Factor readout
Volts or AC Amps
Yes
0 to 600.0 kVAR
0 to 600.0 kVA
0.0% to 99.9%
0 to 600.0 kW
ACD-41PQ
0.10 to 0.99
CAT
600V
(ACD-41PQ)
TRUE
R M S
+/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th & PF > 0.7
+/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th & PF > 0.7
(ACD-40PQ)
+/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th
1.5% of Reading + 6d @ Fund Frequency
1.5% of Reading + 6d @ Fund Frequency
+/-(1.0% Rdg + 5 LSD) @ 50 and 60Hz
+/- 3 LSD @ Harmonics Fund to 21th
+/-(0.5% Rdg + 5 LSD) @ 50 / 60 Hz
z
+/-(0.5% Rdg + 5 LSD)
+/-(1.0% Rdg + 6 LSD)
BASIC ACCURACY
+/-(0.5% Rdg +4 LSD)
+/-(2.0 % Rdg + 3C)
+/-(2.0% Rdg + 6F)
• Automatic polarity
• Low battery indication
• Peak hold
• Data hold
• Large, easy to read LCD display
• Accommodates conductors up to
• Carrying case, test leads,
• Voltage overload protection for all
• Safety CAT III 600V
with backlight
1.77” (45mm) in diameter
batteries (installed), thermocouple
and manual included
functions up to 600V AC/DC
(ADC-41PQ)

ACD-41PQ Summary of contents

Page 1

... The ACD-40’s provide a simple and effective way to verify if the electrical system is affected by harmonics. Add on troubleshooting capabilities with the ACD-40PQ data logging feature or get complete Power analysis with the ACD-41PQ. Increase measuring efficiency with an optional PC interface kit. • TRMS sensing • ...

Page 2

... The ACD-40’s provide a simple and effective way to verify if the electrical system is affected by harmonics. Add on troubleshooting capabilities with the ACD-40PQ data logging feature or get complete Power analysis with the ACD-41PQ. Increase measuring efficiency with an optional PC interface kit. PC Interface kit (PC connection cable with software) RS-232 KIT2 OPTIONAL ACCESSORIES ...

Page 3

... Accuracy 600.0V 0. NMRR: >50dB @ 50/60Hz CMRR: >120dB @ DC, 50/60Hz, Rs=1k Input Impedance 30pF nominal DCV AutoVA Threshold: 2.4VDC nominal (ACD-41PQ) TM ACA & ACV PEAK-rms HOLD (ACD-41PQ only) Response: 65ms to 90% Ohms RANGE Accuracy 999.9 1. Open Circuit Voltage: 0.4VDC typical Audible Continuity Tester Audible threshold: between 10 and 300 ...

Page 4

... ACD-40PQ & ACD-41PQ 1000A Power Quality Clamp-on with THD Measurement Miramar, FL 33025 • Toll Free: 800-327-5060 • Phone: 954-499-5400 • Fax: 866-287-7222 • www.Amprobe.com www.AMPROBE.com ...