FLUKE-125/003S Fluke Electronics, FLUKE-125/003S Datasheet - Page 2

no-image

FLUKE-125/003S

Manufacturer Part Number
FLUKE-125/003S
Description
40MHZ INDUSTRIAL SCOPEMETER+SCC
Manufacturer
Fluke Electronics
Series
ScopeMeter® 120r
Type
Handheldr
Datasheet

Specifications of FLUKE-125/003S

Includes
Alligator Clips, Battery Charger/Adapter, Case, Hook Clips, Probe Set, Software, Test Leads, USB/RS232 Cable
Bandwidth
40MHz
Channels
Dual
Display Type
LCD - Monochrome
Features
Multimeter, RS232/USB Interface, Save and Recall, Trendplot™ Recording
Probe Type
10:1 Voltage Probe (1)
Sampling Rate (per Second)
25MS/s
Input Impedance
1M
Rise Time (typ)
8.75nS
Voltage - Input, Max
CAT III 600V
Voltage - Supply
4.8V Battery, 15VDC Adapter
Lead Free Status / RoHS Status
Lead free / RoHS non-compliant
Oscilloscope mode
Vertical deflection
Bandwidth limiter: User selectable: 10 kHz, 20 MHz
or off
Number of inputs: Two plus external trigger.
All inputs isolated from each other and ground.
Input coupling: AC or DC, with ground level indicator
Input sensitivity: 2 mV/div to 100 V/div (Fluke 190C
Series); 5 mV/div to 100 V/div (Fluke 190B Series)
Normal/invert: On both input channels; switched
separately
Variable attenuator: Variable gain on input channel A
Input voltage: 1000 V CAT II, 600 V CAT III rated—see
“general specifications” for further details
Vertical resolution: 8 bit
Accuracy: ± (1.5 % of reading + 0.04 x range/div)
Input impedance: 1 MW ± 1 % // 15 pF ± 2 pF
Horizontal
Maximum record length: 3000 points per input in
Scope mode; 27,500 points per input in ScopeRecord
roll mode (5 ms/div to 2 min/div)
Accuracy: ± (0.01 % of reading + 1 pixel)
Glitch capture: 50 nsec (at 5 µsec/div to 1 min/div);
250 nsec (at 2 min/div)
Display and acquisition
Visible screen width: 12 divisions
Waveform mathematics: A + B, A - B, A * B, all
with user selectable scaling of resultant; A versus B
(X - Y mode); Frequency Spectrum using FFT analysis
(190C only)
Acquisition modes: Normal, auto, single shot,
ScopeRecord
compare, waveform compare with automatic
“Pass / Fail testing” (in 199C and 196C only)
Trigger and delay
Source: Input A, input B, external trigger input.
All input references isolated from each other and
from ground
Modes: Automatic Connect-and-View,
single shot, edge, delay, video, video line, selectable
pulsewidth, dual slope (190C only), N-cycle
(190C only)
2 Fluke Corporation
Technical specifications 190C and 190B Series
Bandwidth
Rise time
Maximum
real-time
sample rate
Number of
digitizers
Time base
range
Display
Display modes
Persistence
modes
roll, glitch capture, waveform
short/medium/long/infinite
Fluke 199C
Fluke 199B
Fluke 199C
Fluke 199B
200 MHz
2.5 GS/s
Digital persistence:
1.7 ns
ScopeMeter 190C/190B Series, 120 Series and the NEW ScopeMeter 125
Input A, input B, dual, average, replay
Full color LCD
2
Fluke 190C
144 mm
to 5 s/div
5 ns/div
Fluke 196C
Fluke 196B
Fluke 196C
Fluke 196B
100 MHz
1 GS/s
3.5 ns
2
free run,
Monochrome LCD
Fluke 190B
Persistence
Fluke 192B
Fluke 192B
144 mm
on / off
500 MS/s
10 ns/div
to 5 s/div
60 MHz
5.8 ns
2
Connect-and-View
that recognizes signal patterns, automatically sets up
and continuously adjusts triggering, time base and
amplitude. Automatically displays stable waveforms
of complex and dynamic signals like motor drive and
control signals.
Video triggering: NTSC, PAL, PAL+, SECAM. Includes
field 1, field 2 and line select.
Pulse width triggering: Pulse width qualified by time.
Allows for triggering <t, >t, =t, ≠t, where t is select-
able in minimal steps of 0.01 div. or 50 nsec.
Time delay: One full screen of pre-trigger view or up
to 100 screens (= 1200 divisions) of post-trigger delay
Dual slope triggering: Both rising and falling tran-
sitions, when crossing the trigger level, initiate an
acquisition (190C only)
N-cycle triggering: Triggers on N-th occurrence of
a trigger event; N to be set in the range 2 to 99
(190C only)
Automatic capture of 100 screens
The instrument ALWAYS memorizes the last 100
screens (no user setup required). When an anomaly
occurs on screen, the REPLAY button can be pressed to
review the full screen sequence over and over.
or intermittent anomalies and will operate in
“baby-sit” mode and will capture 100 events.
in waveform compare mode to store only matching
(“Pass”) or only non-matching (“Fail”) acquired wave-
forms in the replay memory bank for further analysis.
Replay: Manual or continuous replay. Displays the
captured 100 screens as a “live” animation or under
manual control. Each screen has date- and time-stamp.
Replay storage: Up to 2 sets of 100 screens each
can be saved for later recall and analysis
FFT – Frequency Spectrum Analysis
(190C only)
Shows frequency content of oscilloscope waveform
using Fast Fourier Transform
Window: Automatic, Hamming, Hanning or None
Automatic window: Digitally re-samples acquired
waveform to get optimum frequency resolution in FFT
resultant
Vertical scale: Linear/logarithmic, in volts
Frequency axis: Logarithmic; frequency range
automatically set as function of timebase range of
oscilloscope
Waveform compare and pass/fail testing
Waveform compare: Provides storage and display
of a reference waveform for visual comparison with
newly acquired waveforms. Reference is derived from
an acquired waveform and can be modified in the
ScopeMeter or externally using FlukeView
Pass/Fail Testing (199C, 196C): In waveform com-
pare mode, the Color Scopemeter can be set up to
store only matching (“Pass”) or only non-matching
(“Fail”) acquired waveforms in the replay memory
bank for further analysis.
Automatic scope measurements
Vdc, Vac rms, Vac+dc, Vpeak max, Vpeak min, Vpeak to
peak, Aac, Adc, Aac+dc, frequency (Hz), risetime, fall-
time, power factor, Watts, VA, VA reactive, phase, pulse
width (pos/neg), dutycycle (pos/neg), temperature °C,
temperature °F, dBV, dBm into 50 W and 600 W
width modulated motordrives and frequency inverters
Instrument can be set up for triggering on glitches
Alternatively, the 199C and 196C can be set up
Vpwm ac, Vpwm ac+dc for measurement on pulse
: Advanced automatic triggering
®
Software.