LTC4260ISW#TR Linear Technology, LTC4260ISW#TR Datasheet - Page 18

MS-Hot Swap/High Voltage, 48V Hot Swap Controller With I2C ADC

LTC4260ISW#TR

Manufacturer Part Number
LTC4260ISW#TR
Description
MS-Hot Swap/High Voltage, 48V Hot Swap Controller With I2C ADC
Manufacturer
Linear Technology
Datasheet

Specifications of LTC4260ISW#TR

Lead Free Status / Rohs Status
Not Compliant
APPLICATIO S I FOR ATIO
LTC4260
address with the R/W bit now set to one. The LTC4260
acknowledges and sends the contents of the requested
register. The transmission is ended when the master
sends a STOP condition. If the master acknowledges the
transmitted data byte, as in a Read Word command
(Figure 12), the LTC4260 will repeat the requested register
as the second data byte.
Note that the Register Address pointer is not cleared at the
end of the transaction. Thus the Receive Byte protocol can
be used to repeatedly read a specific register.
Alert Response Protocol
The LTC4260 implements the SMBus Alert Response
Protocol as shown in Figure 11. If enabled to do so through
the ALERT register B, the LTC4260 will respond to faults
by pulling the ALERT pin low. Multiple LTC4260s can
share a common ALERT line and the protocol allows a
master to determine which LTC4260s are pulling the line
18
SDA
SCL
CONDITION
START
S
U
U
ADDRESS
a6 - a0
1 - 7
W
R/W
8
Figure 6. Data Transfer Over I
ACK
9
U
1 - 7
b7 - b0
DATA
low. The master begins by sending a START bit followed
by the special Alert Response Address (0001 100)b with
the R/W bit set to one. Any LTC4260 that is pulling its
ALERT pin low will acknowledge and begin sending back
its individual slave address.
An arbitration scheme ensures that the LTC4260 with the
lowest address will have priority; all others will abort their
response. The successful responder will then release its
ALERT pin while any others will continue to hold their
ALERT pins low. Polling may also be used to search for any
LTC4260 that have detected faults. Any LTC4260 pulling
its ALERT pin low will also release it if it is individually
addressed during a read or write transaction.
The ALERT signal will not be pulled low again until the
FAULT register indicates a different fault has occurred or
the original fault is cleared and it occurs again. Note that
this means repeated or continuing faults will not generate
alerts until the associated FAULT register bit has been
cleared.
8
2
C or SMBus
ACK
9
1 - 7
b7 - b0
DATA
8
ACK
9
CONDITION
STOP
P
4260 F06
4260fa

Related parts for LTC4260ISW#TR