Y92P-48GL Omron, Y92P-48GL Datasheet - Page 4

no-image

Y92P-48GL

Manufacturer Part Number
Y92P-48GL
Description
PNL CVR LITE GRAY
Manufacturer
Omron
Series
H3CR-Gr
Datasheets

Specifications of Y92P-48GL

Accessory Type
Cover, Panel
Color
Gray, Light
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
H3CR-G Series
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Y92P48GL
■ Characteristics
Note: Refer to the Life-test Curve.
Accuracy of operating
time
Setting error
Accuracy of Star-delta
transfer time
Reset voltage
Influence of voltage
Influence of temperature ±1% FS max.
Insulation resistance
Dielectric strength
Impulse withstand
voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
EMC
Case color
Degree of protection
Weight
±0.2% FS max.
±5% FS ±50 ms max.
±25% FS + 5 ms max.
10% max. of rated voltage
±0.2% FS max.
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-current-carrying metal parts)
2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit)
2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities)
1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)
3 kV (between power terminals)
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts)
±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
Malfunction: 8 kV
Destruction: 15 kV
Destruction: 10 to 55 Hz with 0.75-mm single amplitude for 2 hrs each in three directions
Malfunction: 10 to 55 Hz with 0.5-mm single amplitude for 10 min each in three directions
Destruction: 980 m/s
Malfunction: 294 m/s
Operating:
Storage:
Operating:
Mechanical: 20 million operations min. (under no load at 1,800 operations/h)
Electrical:
(EMI)
Emission Enclosure:
Emission AC Mains:
(EMS)
Immunity ESD:
Immunity RF-interference from AM Radio Waves:
Immunity RF-interference from Pulse-modulated Radio Waves: IEC61000-4-3: 10 V/m (900±5 MHz) (level 3)
Immunity Conducted Disturbance: IEC61000-4-6:
Immunity Burst:
Immunity Surge:
Light Gray (Munsell 5Y7/1)
IP40 (panel surface)
H3CR-G8L: approx. 110 g; H3CR-G8EL: approx. 130 g
−10°C to 55°C (with no icing)
−25°C to 65°C (with no icing)
100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) (See note)
35% to 85%
2
2
three times each in six directions
three times each in six directions
EN61812-1
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61812-1
IEC61000-4-2:
IEC61000-4-4:
IEC61000-4-5:
6 kV contact discharge (level 3)
8 kV air discharge (level 3)
IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
10 V (0.15 to 80 MHz) (level 3)
2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
1 kV line to line (level 3)
2 kV line to ground (level 3)
H3CR-G
4

Related parts for Y92P-48GL