85100635 Crouzet USA, 85100635 Datasheet - Page 295

no-image

85100635

Manufacturer Part Number
85100635
Description
SAFETY RLY, KZH3-RS 230VAC
Manufacturer
Crouzet USA
Series
KZH3-RSr
Datasheet

Specifications of 85100635

Contact Form
3PST (3 Form A)
Contact Rating (current)
6A
Switching Voltage
440VAC - Max
Relay Type
Safety
Coil Voltage
230VAC
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Coil Type
-
Coil Current
-
Lead Free Status / Rohs Status
 Details
For more information www.crouzet.com
Dimensions
KNA3-XS
Connections
KNA3-XS
Principles
Control devices :
The KZP3-RS is used to obtain and maintain a category 4 level of safety for an installation with two control devices.
Depending on the degree of safety required, KNA3-XS / KNA3-RS / KZP3-RS can receive the following components as inputs :
- pushbutton for start or validation (Y1-Y2)
-emergency stop pushbuttons with
- position sensors (limit switches) with
A positive break operation device must be used if a single channel is used.
To increase the degree of safety, one "N/C" auxiliary contact per power contactor is wired in series with the start (or validation) pushbutton, to ensure self-
checking in this part of the installation.
Control devices :
The KNA3 / KZP3 has three "N/O" safety contacts (13-14/23-24/33-34) and one "N/C" signalling contact (41-42). One or more control devices may be
wired up to the breaking capacity of the safety contacts : 1500 VA. However, to limit internal heating, it is advisable not to exceed 10 A thermal for all three
contacts. The signalling contact can be wired on a PLC input or integrated into a fault signalling system.
Extending the number of contacts :
The number of contacts can be extended and the breaking capacity thus increased. To do this, use the KZE3-XS.
A1-A2 Power supply Control device (s)
Y1-Y2 Start / validation
13-14/23-24/33-34 "N/O" safety contacts
41-42 "N/C" signaling contacts
one or two contacts (A1-A2)
two contacts KNA3-RS : Y11-Y12 and Y21-Y22,
two contacts KZP3-RS : Y11-Y12 / Y21-Y22 and Y31-Y32 / Y41-Y42
one or two contacts (A1-A2)
two contacts KNA3-RS : Y11-Y12 and Y21-Y22,
two contacts KZP3-RS : Y11-Y12 / Y21-Y22 and Y31-Y32 / Y41-Y42
118
113
90
13
A1
A2
14
PWR
OUT
13 23 33 41
14 24 34 42
KNA3-XS
Y1
23
41
24
Y2
33
42
34
22,5
Mounting - Removing
KNA3-RS
A1-A2 Power supply
Y11-Y12 / Y21-Y22 Redundant inputs with
differentiated voltage for control devices
Y1-Y2 Start/validation
S1-S2 Short-circuit protection on start /
validation input
X1-X2 Return loop
13-14/23-24/33-34 "N/O" safety contacts
41-42 "N/C" signalling contacts
Y11 Y12
A1
A2
Y1
PWR
OUT
PE Y21 Y22
X1
X2 Y11
Y2
Y1
13 23 33 41
14 24 34 42
13
S1
KNA3-RS
14
S2
23
24
33
41
42
34
KNA3-RS / KZP3-RS
KZP3-RS
A1-A2 Power supply
Y11-Y12 / Y21-Y22 Redundant inputs with
differentiated voltage for control devices
Y31-Y32 / T41-T42 Redundant inputs with
differentiated voltage for control devices
Y1-Y2 Start/validation
S1-S2 / S3-S4 Short-circuit protection on
start/validation input
13-14/23-24/33-34 "N/O" safety contacts
41-42 "N/C" signalling contacts
Y12
A1
A2 Y11 Y1
13
118
113
PWR
OUT
Y22
23
S1
90
Y21
33
S2
13 23 33 41
14 24 34 42
S3 Y32 Y42
S4 Y31 Y41
KZP3-RS
Y2
14
41
24
42
34
45
295
10