ATV71HC25Y SQUARE D, ATV71HC25Y Datasheet
ATV71HC25Y
Related parts for ATV71HC25Y
ATV71HC25Y Summary of contents
Page 1
... Characteristics Complementary Product destination Power supply voltage limits Power supply frequency Power supply frequency limits Speed range Speed accuracy Apr 1, 2012 ATV71HC25Y variable speed drive ATV71 - 250kW - 690V Main Range of product Altivar 71 Product or component Variable speed drive type Product specific appli- ...
Page 2
Torque accuracy Transient overtorque Braking torque Synchronous motor control profile Regulation loop Motor slip compensation Diagnostic Output voltage Insulation Type of cable for mounting in an enclosure Electrical connection Tightening torque Supply Analogue input number Analogue input type Input sampling ...
Page 3
Discrete input type Discrete input logic Acceleration and deceleration ramps Braking to standstill Protection type Insulation resistance Frequency resolution Communication port protocol Type of connector Physical interface Transmission frame Transmission rate Data format Number of addresses Method of access Marking ...
Page 4
Environment Noise level Dielectric strength Electromagnetic compatibility Standards Product certifications Pollution degree IP degree of protection Vibration resistance Shock resistance Relative humidity Ambient air temperature for operation Ambient air temperature for storage Operating altitude RoHS EUR status RoHS EUR conformity ...
Page 5
... Option cards: I/O extension cards, communication cards or "Controller Inside” programmable card. Dimensions with 2 Option Cards (1) Dimensions 595 392 540 Dimensions in in 23.43 15.43 21.26 (1) Option cards: I/O extension cards, communication cards or "Controller Inside” programmable card. ATV71HC25Y 540 920 150 21.26 36.22 5. 920 ...
Page 6
Drive with Braking Unit VW3A7101 Dimensions with or without 1 Option Card ( 1190 377 (1) Option cards: I/O extension cards, communication cards or "Controller Inside” programmable card. Dimensions with 2 Option Cards (1) ...
Page 7
... To ensure proper air circulation in the drive: ● Fit ventilation grilles. ● Ensure that there is sufficient ventilation. If there is not, install a forced ventilation unit with a filter. The openings and/or fans must provide a flow rate at least equal to that of the drive fans (refer to the product characteristics). ATV71HC25Y X1 in in. 5. in. ...
Page 8
Use special filters with IP 54 protection. ● Remove the blanking cover from the top of the drive. Dust and Damp Proof Metal Enclosure (IP 54) The drive must be mounted in a dust and damp proof enclosure in ...
Page 9
... All terminals are located at the bottom of the drive. Fit interference suppressors on all inductive circuits near the drive or connected on the same circuit, such as relays, contactors, solenoid valves, fluorescent lighting, etc. Wiring Diagram Conforming to Standards EN 954-1 Category 1, IEC/EN 61508 Capacity SIL1, in Stopping Category 0 According to IEC/EN 60204-1 ATV71HC25Y 9 ...
Page 10
Three-Phase Power Supply with Downstream Breaking via Switch Disconnector A1 ATV71 drive L1 DC choke Q1 Circuit-breaker Q2 Switch disconnector (Vario) (1) Line choke (three-phase), mandatory for ATV71HC11Y…HC63Y drives (except when a special transformer is used (12-pulse)). (2) For ATV71HC40N4 ...
Page 11
... ATV71 drive A2 Preventa XPS AC safety module for monitoring emergency stops and switches. One safety module can manage the “Power Removal” function for several drives on the same machine. In this case, each drive must connect its PWR terminal to its + 24 V via the safety contacts on the XPS ...
Page 12
... ATV71 drive A2 Preventa XPS ATE safety module for monitoring emergency stops and switches. One safety module can manage the "Power Removal” (5) safety function for several drives on the same machine. In this case the time delay must be adjusted on the drive controlling the motor that requires the longest stopping time. In addition, each drive must connect its PWR terminal to its + 24 ...
Page 13
... Product data sheet Performance Curves Derating Curves The derating curves for the drive nominal current (In) depend on the temperature and the switching frequency. For intermediate temperatures (e.g. 55°C), interpolate between 2 curves. X Switching frequency ATV71HC25Y 13 ...