D2S-01L Omron, D2S-01L Datasheet - Page 2

Subminiature Basic Switch

D2S-01L

Manufacturer Part Number
D2S-01L
Description
Subminiature Basic Switch
Manufacturer
Omron
Series
D2Sr
Type
Subminiature Basicr
Datasheet

Specifications of D2S-01L

Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
0.1A @ 30VDC
Actuator Type
Lever, Straight
Mounting Type
Chassis Mount
Termination Style
Solder Lug
Operating Force
50gf
Contact Form
SPDT
Contact Rating
0.1 Amp at 30 VoltsDC
Actuator
Lever
Ingress Protection
IP40
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
D2S01L
D2S
Specifications
Note:
Note:
2
D2S-10
D2S-5
D2S-01
Operating speed
Operating frequency
Insulation resistance
Contact resistance
Dielectric strength (see note 3)
Vibration resistance
(see note 4)
Shock resistance (see note 4)
Durability (see note 5)
Degree of protection
Degree of protection against elec-
tric shock
Proof tracking index (PTI)
Ambient operating temperature
Ambient operating humidity
Weight
(initial value) (see note 2)
Ratings
Characteristics
Model
The ratings values apply under the following test conditions:
Ambient temperature: 20±2°C
Ambient humidity: 65±5%
Operating frequency: 30 operations/min
1. The data given above are initial values.
2. The specifications shown with the OF values are those for pin plunger models.
3. The dielectric strength shown in the table is for models with a Separator.
4. For the pin plunger models, the above values apply for use at both the free position and total travel position. For the lever models,
5. For testing conditions, consult your OMRON sales representative.
they apply at the total travel position.
250 VAC
125 VAC
250 VAC
125 VAC
30 VDC
Rated voltage
Item
0.1 mm to 1 m/s (pin plunger models)
Mechanical: 400 operations/min max.
Electrical:
100 MΩ min. (at 500 VDC)
OF 1.47 N {150 gf}:
OF 0.49 N {50 gf}:
1,000 VAC, 50/60 Hz for 1 min between terminals of same polarity
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground
1,500 VAC, 50/60 Hz for 1 min between each terminal and non-current-carrying metal parts
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Destruction: OF 1.47 N {150 gf}: 1,000 m/s
Malfunction: OF 1.47 N {150 gf}: 300 m/s
Mechanical:
Electrical:
IEC IP40
Class I
175
–25° to 85°C (at ambient humidity of 60% max.) (with no icing or condensation)
85% max. (for 5°C to 35°C)
Approx. 1.6 g (pin plunger models)
10.1 A
5 A
3 A
0.1 A
0.1 A
Resistive load
30 operations/min max.
OF 0.49 N {50 gf}: 500 m/s
OF 0.49 N {50 gf}: 200 m/s
D2S-10 models: 10,000,000 operations min. (60 operations/min)
D2S-5, D2S-01 models: 30,000,000 operations min. (60 operations/min)
(Refer to Engineering Data.)
D2S-10 models: 50,000 operations min. (30 operations/min)
D2S-5, D2S-01 models: 200,000 operations min. (30 operations/min)
(Refer to Engineering Data.)
D2S-10, D2S-5 models: 30 mΩ max.
D2S-01 models:
D2S-5 models:
D2S-01 models:
2
2
2
{approx. 50G} max.
{approx. 30G} max.
{approx. 20G} max.
2
{approx. 100G} max.
50 mΩ max.
50 mΩ max.
100 mΩ max.
D2S

Related parts for D2S-01L