G2R-24-T130 DC24 Omron, G2R-24-T130 DC24 Datasheet - Page 5

RELAY

G2R-24-T130 DC24

Manufacturer Part Number
G2R-24-T130 DC24
Description
RELAY
Manufacturer
Omron
Series
G2Rr
Datasheet

Specifications of G2R-24-T130 DC24

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
5A
Switching Voltage
380VAC, 125VDC - Max
Coil Type
Standard
Coil Current
21.8mA
Coil Voltage
24VDC
Turn On Voltage (max)
16.8 VDC
Turn Off Voltage (min)
3.6 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
5A @ 250VAC
Control On Voltage (max)
16.8 VDC
Control Off Voltage (min)
3.6 VDC
Contact Rating
5 A
Contact Termination
Quick Connect
Mounting Style
Plug-In
Power Consumption
530 mW
Contact Material
Silver Alloy
Coil Resistance
1.1 K Ohms
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G2R-24-T130-DC24
G2R24T130DC24
G2R
PCB/Fully sealed Relays
Note:
Latching Relays
Note:
I
Standard Relays
Note:
Number of poles
Load
Rated load
Rated carry current
Max. switching voltage 380 VAC, 125 VDC
Max. switching current 8 A
Max. switching power
Failure rate
(reference value)
Number of poles
Load
Rated load
Rated carry current
Max. switching voltage 380 VAC, 125 VDC
Max. switching current 5 A
Max. switching power
Failure rate
(reference value)
Contact resistance
Operate (set) time
Release (reset) time
Max. operating frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
Characteristics
P level:
P level:
Values in the above table are the initial values.
*2,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A socket is mounted.
Item
Item
l
l
60
60
= 0.1 x 10
= 0.1 x 10
1 pole
Resistive load
(cos = 1)
8 A at 250 VAC;
8 A at 30 VDC
8 A
2,000 VA,
240 W
100 mA at 5 VDC
1 pole
Resistive load
(cos = 1)
5 A at 250 VAC;
5 A at 30 VDC
5 A
1,250 VA, 150 W
100 mA at 5 VDC
–6
-6
/operation
/operation
30 m
15 ms max.
AC: 10 ms max.; DC: 5 ms max. (w/built-in diode: 20 ms max.)
Mechanical: 18,000 operations/hr
Electrical:
1,000 M
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts
of same polarity
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s
Malfunction: 200 m/s
Mechanical: AC coil: 10,000,000 operations min.;
DC coil:
Electrical:
Operating: 40°C to 70°C (with no icing)
Operating: 5% to 85%
Approx. 17 g (plug-in terminal: approx. 20 g)
max. (high-capacity type: 100 m
Inductive load
(cos = 0.4;
L/R = 7 ms)
6 A at 250 VAC;
4 A at 30 VDC
1,500 VA,
120 W
General-purpose (single contact)
min. (at 500 VDC)
20,000,000 operations min. (at 18,000 operations/hr)
100,000 operations min. (at 1,800 operations/hr under rated load)
1,800 operations/hr (under rated load)
Inductive load
(cos = 0.4;
L/R = 7 ms)
3.5 A at 250 VAC;
2.5 A at 30 VDC
875 VA, 75 W
2
1 pole
when energized; 100m/s
2
2 poles
Resistive load
(cos = 1)
4 A at 250 VAC;
4 A at 30 VDC
4 A
380 VAC, 125 VDC
4 A
1,000 VA,
120 W
10 mA at 5 VDC
max.)
Inductive load
(cos = 0.4;
L/R = 7 ms)
1.5 A at 250 VAC;
2.5 A at 30 VDC
375 VA,
75 W
2 poles
Resistive load
(cos = 1)
3 A at 250 VAC;
3 A at 30 VDC
3 A
380 VAC, 125 VDC
3 A
750 VA, 90 W
10 mA at 5 VDC
2
when no energized
50 m
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
3,000 VAC, 50/60 Hz for 1 min between contacts
of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts
of same polarity
max.
1 pole
Resistive load
(cos = 1)
5 A at 250 VAC;
5 A at 30 VDC
5 A
380 VAC, 125 VDC
5 A
1,250 VA,
150 W
1 mA at 5 VDC
2 poles
Bifurcated contact
Inductive load
(cos = 0.4;
L/R = 7 ms)
1.5 A at 250 VAC;
2 A at 30 VDC
375 VA, 60 W
Inductive load
(cos = 0.4;
L/R = 7 ms)
2 A at 250 VAC;
3 A at 30 VDC
500 VA,
90 W
G2R
5

Related parts for G2R-24-T130 DC24