G4A-1A-PE-T130 DC12 Omron, G4A-1A-PE-T130 DC12 Datasheet - Page 2

no-image

G4A-1A-PE-T130 DC12

Manufacturer Part Number
G4A-1A-PE-T130 DC12
Description
Power PCB Relay
Manufacturer
Omron
Series
G4Ar
Datasheet

Specifications of G4A-1A-PE-T130 DC12

Relay Type
General Purpose
Contact Form
SPST-NO (1 Form A)
Contact Rating (current)
20A
Switching Voltage
250VAC - Max
Coil Type
Standard
Coil Current
75mA
Coil Voltage
12VDC
Turn On Voltage (max)
8.4 VDC
Turn Off Voltage (min)
1.2 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPST-NO (1 Form A)
Contact Rating @ Voltage
20A @ 250VAC
Control On Voltage (max)
8.4 VDC
Control Off Voltage (min)
1.2 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G4A-1A-PE-T130DC12
G4A-1A-PE-T130DC12BYOMZ(C)
G4A-1A-PE-T130DC12BYOMZ(C)
G4A1APET130DC12
■ Coil Ratings
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
■ Endurance
With Motor Load
With Overload
With Inverter Load
■ Characteristics
Note: The data shown above are initial values.
222
Rated voltage
Rated current
Coil resistance
Coil inductance
(ref. value)
Pick-up voltage (max.)
Dropout voltage (min.)
Maximum coil voltage
Power consumption
250 VAC:
Inrush current: 80 A, 0.3 s (cosφ= 0.7)
Break current: 20 A (cosφ = 0.9)
250 VAC:
Inrush current: 80 A (cosφ= 0.7)
Break current: 80 A (cosφ = 0.7)
100 VAC;
Inrush current: 200 A (0−P)
Break current: 20 A
Contact resistance
Operate time
Release time
Max. operating frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Service Life
Ambient temperature
Ambient humidity
Weight
2. Operating characteristics are measured at a coil temperature of 23°C.
3. Max. permissible voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage.
Load conditions
Load conditions
Load conditions
Power PCB Relay
Armature OFF
Armature ON
100 mΩ max.
20 ms max.
10 ms max.
Mechanical: 18,000 operations/hr
1,000 MΩ min. (at 500 VDC)
4,500 VAC 50/60 Hz for 1 min between coil and contacts
1,000 VAC 50/60 Hz for 1 min between contacts of same polarity
Destruction: 10 to 55, 1.5-mm double amplitude
Malfunction: 10 to 55, 1.5-mm double amplitude
Destruction: 1,000 m/s
Malfunction: 200 m/s
Mechanical:
Motor load:
Inverter load:
Operating: −20°C to 60°C (with no icing)
Operating: 5% to 85%
Approx. 23 g
G4A
5 VDC
180 mA
27.8 Ω
---
---
70% of rated voltage max.
10% of rated voltage min.
160% of rated voltage at (23°C)
Approx. 0.9 W
ON:1.5 s
OFF:1.5 s
ON:1.5 s
OFF:99 s
ON:3 s
OFF:5 s
2,000,000 operations min. (at 18,000 operations/hr)
100,000 operations min. (ON/OFF: 1.5 s)
30,000 operations min. (ON: 3 s, OFF: 5 s
Switching frequency
Switching frequency
Switching frequency
2
2
12 VDC
75 mA
160 Ω
0.8 H
1.1 H
200,000 operations
1,500 operations
30,000 operations
Electrical endurance
Electrical endurance
Electrical endurance
24 VDC
37.5 mA
640 Ω
3.5 H
4.8 H

Related parts for G4A-1A-PE-T130 DC12