G4Q-212S AC200/(220) Omron, G4Q-212S AC200/(220) Datasheet - Page 3

no-image

G4Q-212S AC200/(220)

Manufacturer Part Number
G4Q-212S AC200/(220)
Description
RELAY
Manufacturer
Omron
Series
G4Qr
Datasheet

Specifications of G4Q-212S AC200/(220)

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
5A
Switching Voltage
250VAC, 250VDC - Max
Coil Type
Standard
Coil Current
29.1mA
Coil Voltage
220VAC
Turn On Voltage (max)
176 VAC
Turn Off Voltage (min)
22 VAC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
5A @ 220VAC
Control On Voltage (max)
176 VAC
Control Off Voltage (min)
22 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G4Q-212SAC200/(220)
G4Q212SAC200220
■ Characteristics
Note: 1. The data shown above are initial values.
Engineering Data
Contact resistance (See note 2.)
Operate time (See note 3.)
Max. operating frequency
Insulation resistance (See note 4.)
Dielectric strength
Vibration resistance
Shock resistance
Endurance
Error rate (See note 6.)
Ambient temperature
Ambient humidity
Weight
Maximum Switching Power
2. The contact resistance was measured with 0.1 A at 5 VDC using the voltage drop method.
3. The operate time was measured with the rated voltage imposed with any contact bounce ignored at an ambient temperature of 23°C.
4. The insulation resistance was measured with a 500-VDC megger applied to the same places as those used for checking the dielectric
5. The electrical endurance was measured at an ambient temperature of 23°C.
6. This value was measured at a switching frequency of 60 operations per minute. The value in parentheses is for the cased model.
strength.
DC inductive load
L/R = 7 ms
DC resistive load
Switching voltage (V)
AC inductive load
(cosφ = 0.4)
AC resistive load
50 mΩ max.
60 ms max.
Mechanical:
Electrical:
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min between coil and contact (1,000 VAC, 50/60 Hz for 1 min between con-
tacts of same polarity) (2,000 VAC between contacts of different polarities)
Destruction:
Malfunction:
Destruction:
Malfunction:
Mechanical:
Electrical:
1 A at 5 VDC (0.1 A at 5 VDC)
Operating:
Operating:
Open model: Approx. 240 g; cased model: Approx. 340 g
1,200 operations/hr
1,200 operations/hr (under rated load)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
500 m/s
100 m/s
1,200 operations/hr) (See note 5.)
–10°C to 55°C (with no icing or no condensation)
5% to 85%
5,000,000 operations min. (at operating frequency of 1,200 operations/hr)
500,000 operations min. (under rated load and at operating frequency of
2
2
Electrical Endurance
10,000
7,000
5,000
3,000
1,000
700
500
300
100
70
50
30
220 VAC resistive load
220 VAC inductive load
(cosφ = 0.4)
Switching current (A)
24 VDC resistive load
24VDC inductive load
L/R = 7 ms
G4Q
3