G5V-13 DC3 Omron, G5V-13 DC3 Datasheet - Page 2

Low Signal Relay

G5V-13 DC3

Manufacturer Part Number
G5V-13 DC3
Description
Low Signal Relay
Manufacturer
Omron
Series
G5V-1r
Datasheets

Specifications of G5V-13 DC3

Coil Voltage
3VDC
Contact Form
SPDT
Coil Current
50 mA
Coil Type
Relay
Power Consumption
150 mW
Contact Carry Current
2 A
Termination Style
Solder Pin
Maximum Switching Current
1 A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Mounting Type
-
Circuit
-
Contact Rating @ Voltage
-
Relay Type
-
Control On Voltage (max)
-
Control Off Voltage (min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G5V-13DC3
G5V13DC3
G5V-1
I
Note:
I
Note:
Note:
I
UL1950 (File No. E41515)/CSA C22.2 No.0, No.14 (File No. LR31928)
Load
Rated load
Contact material
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Failure rate (reference value)
(See note.)
Contact resistance (See note 1.)
Operate time (See note 2.)
Release time (See note 2.)
Max. operating frequency
Insulation resistance (See note 2.)
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
G5V-1
Approved Standards
Characteristics
Contact Ratings
Model
P level:
This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 100 Ω . This value
may vary depending on the operating environment. Always double-check relay suitability under actual operating conditions.
The values here are initial values.
1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
2. Values in parantheses are actual values.
3. The insulation resistance was measured with a 500-VDC megohmmeter between coil and contacts and a 250-VDC megohm-
meter between contacts with the same polarity applied to the same parts as those used for checking the dielectric strength.
λ
60
SPDT
= 0.1 x 10
Contact form
–6
/operation
3 to 24 VDC
Coil ratings
Resistive load (cos φ = 1)
0.5 A at 125 VAC; 1 A at 24 VDC
Ag + Au-Alloy
2 A
125 VAC, 60 VDC
1 A
62.5 VA, 30 W
1 mA at 5 VDC
100 m Ω max.
5 ms max. (approx. 2.5 ms)
5 ms max. (approx. 0.9 ms)
Mechanical: 36,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
1,000 M Ω min. (at 500 VDC between coil and contacts, at 250 VDC between contacts of same
polarity.)
1,000 VAC, 50/60 Hz for 1 min between coil and contacts
400 VAC, 50/60 Hz for 1 min between contacts of same polarity
1,500 V (10 x 160 µs) between coil and contacts (conforms to FCC Part 68)
Destruction: 10 to 55 to 10 Hz, 1.65-mm single amplitude (3.3-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 1.65-mm single amplitude (3.3-mm double amplitude)
Destruction: 1,000 m/s
Malfunction: 100 m/s
Mechanical: 5,000,000 operations min. (at 18,000 operations/hr)
Electrical: 100,000 operations min. (under rated load, at 1,800 operations/hr)
Operating: − 40°C to 70°C (with no icing)
Operating: 5% to 85%
Approx. 2 g
0.5 A, 125 VAC (general use)
0.3 A, 110 VDC (resistive load)
1 A, 30 VDC (resistive load)
2
2
Contact ratings
G5V-1
47

Related parts for G5V-13 DC3